Electrical permit history — 5679 E Glenn St

5679 E Glenn St, Tucson — built 1910, with 48 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Commercial property

5679 E Glenn St

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1910 — 1910s commercial stock · HVAC 2002 (finaled)

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2024 historic preservation zone/historic landmark permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Nothing permitted on the service or distribution shows in the record we read, which for a building of this era leaves the original switchgear generation in play. Obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown — worth establishing what is actually installed before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalLikely dueLast permitted 2002 (24 years ago). Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Equipment from before about 2010 generally runs R-22, which has not been produced since 2020 — repairs mean reclaimed refrigerant at a price that often exceeds replacing the unit. T02EL01056 — ELECTRIC:BOILER RETROFIT
  • Fire alarm & life safetyPermitted — completion not confirmedA 2020 permit specifies this work (the permit description states “Fire Alarm & Detection Systems - Install a wireless an cellular smoke detection and alarm system; Fire Alarm Systems - New Sq Ft: 2300; Fire Alarm Systems - # New Stories: 1”), but the available record does not show a final inspection. The permit expired without a confirmed final status. Official status: Expired. T20FC00274 — Fire Alarm & Detection Systems - Install a wireless an cellular smoke detection and alarm system; Fire Alarm Systems - New Sq Ft: 2300; Fire Alarm Systems - # New Stories: 1
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    A pool or spa was permitted in 2023. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Worth confirming

    Solar was permitted here in 2019. That means there is an existing interconnection, and the main breaker and busbar rating already carry a PV backfeed — so anything else you add (an EV charger, a heat pump) has to be checked against what is left under the 120% rule, not against the service size alone.

  • Routine

    A trade permit was pulled in 2002. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 16,287 sq ft (county building-footprint layer, 11 structures; 1 neighbouring structure crossing the lot line excluded)
Usable for solar, planning estimate
≈ 11,400 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 125 kW — roughly 310 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 210,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$17,000–$27,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “El Con Mall - Reid Park Area”, is about 2.9 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
11014015A
Year constructed
1910 (assessor record)
Permitting authority
Tucson
Zoning
HRX-2
Property type
Municipal Park/Recreational Property
Building area
6,795 sq ft
Historic preservation
(City of Tucson)

The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2025. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2025. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 48 building permits for this parcel dated between 1997 and 2025. By category the work is trade permit (15), addition / alteration (12), zoning compliance (6) and historic preservation zone/historic landmark (4). 25 of them carry a final inspection; the other 23 were issued, expired or are still open, which is not the same as work completed. There are 5 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 11014015A. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All institutional and public property · Commercial property in 85712 · Commercial & industrial reports · Homes in 85712 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The FEMA map linked above is the National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on E GLENN ST hold 1,067 City permits on record, 217 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (53 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2025SD-1125-00173Historic Preservation Zone/Landmark - MinorIn Review
2025TC-COM-1025-01908Commercial Addition/Alteration PermitExpired
2024TC-COM-0623-01524Commercial New Building PermitNeeds Resubmittal
2024TC-COM-0224-00319Commercial Addition/Alteration PermitIssued
2024SD-0324-00027Historic Preservation Zone/Historic LandmarkComplete
2024TD-DEV-0123-00113Development PackageIssued
2024TC-COM-1123-02730Commercial Addition/Alteration PermitInspections Complete
2023SD-0923-00102Historic Preservation Zone/Historic LandmarkComplete
2023SD-0823-00093Historic Preservation Zone/Historic LandmarkNeeds Resubmittal
2023T21CM06468Commercial Addition/Alteration PermitComplete
2023DP22-0235Development PackageComplete
2022T22CM08028Commercial Trade PermitIssued
2022SD-1122-00005Historic Preservation Zone/Historic LandmarkComplete
2022recordRight-of-Way (ROW) Permit - GeneralComplete
2022T22CM02664Commercial Addition/Alteration PermitComplete
2022T22DV03265EMERGENCYCOMPLIAN
2022T22SA00198Zoning ComplianceComplete
2021T21SA00508Zoning ComplianceApproved
2021T21SA00472Zoning ComplianceApproved
2021T21FO00762Special Events Fire Permit - VendorComplete
2020T20FC00274Fire Alarm System PermitExpired
2019T19SA00119Zoning ComplianceComplete
2019DP19-0019Development PackageWithdrawn
2016T16DV03932MULTI-AGENCY INSPECTION TEAMNOVERIFY
2016T16DV03933MULTI-AGENCY INSPECTION TEAMNOVERIFY
2016T16DV03934MULTI-AGENCY INSPECTION TEAMNOVERIFY
2016T16DV03935MULTI-AGENCY INSPECTION TEAMNOVERIFY
2015T15SA00162Zoning ComplianceDenied
2014T14CM00241Commercial Trade PermitWithdrawn
2012T12PL00145Residential Trade PermitCanceled
2011T11EL00076Commercial Trade PermitCanceled
2006T06OT01325Commercial Addition/Alteration PermitComplete
2006T06SA00076Zoning ComplianceCanceled
2005T05OT00697Peddler PermitCanceled
2005T05CM00282Commercial Addition/Alteration PermitComplete
2002T02EL01056Commercial Trade PermitComplete
2002T02EL00363Commercial Trade PermitComplete
2001T01BU01544Commercial Addition/Alteration PermitCanceled
2001T01CM01103Commercial Addition/Alteration PermitComplete
2001T01EL00533Commercial Trade PermitComplete
2001T01ME00191Commercial Trade PermitWithdrawn
2000T99CM05178Commercial Addition/Alteration PermitComplete
1999T99ME00860Commercial Trade PermitComplete
1998T98PL01859Residential Trade PermitComplete
1998T97CM03498Commercial Addition/Alteration PermitComplete
1998T98EL00916Commercial Trade PermitCanceled
1998T98CM02127Commercial Addition/Alteration PermitCanceled
1998T97PL01054Commercial Trade PermitCanceled
1998T98EL00526Commercial Trade PermitComplete
1998T98ME00062Commercial Trade PermitComplete
1997T97BU00189Commercial Trade PermitComplete
1997T97BU00293Commercial DemolitionComplete
1997T97BU00064GradingWithdrawn

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 11014015A — 48 City permits on file from 1997 to 2025 and 5 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-09-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.