Electrical permit history — 5350 E Glenn St

5350 E Glenn St, Tucson — built 1999, with 15 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

5350 E Glenn St

Build year not published — permits on file from 1999 · 15 permits on record; no permitted panel/service or HVAC work among them

Parcel
11012009B
Built
1999 (earliest permit on file)
Jurisdiction
Tucson
Zoning
O-3
Assessor use
Gas-Electric Transmission Operating Prop
Parcel size
1.83 acres
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 5350 E Glenn St, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2023 fire construction permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2023 fire construction permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentLast permitted 2023 (3 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-1123-01292 — Swap out existing Generator on existing concrete pad
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Most recent permit on record for this parcel: 2024-06-18 (TC-UTL-0624-00027) — T533 - 6' to 9' mount and equipment swap on an existing 65' monopole. No height increase or ground disturbance. PROPOSED SITE BUILD OF AN UNMANNED TELECOMMUNICATIONS FACILITY, CONSISTING OF THE FOLLOWING: ?? REMOVAL OF (9) AT&T REMOTE RADIO UNITS (RRU'S) ?? REMOVAL OF (3) AT&T BACK-TO-BACK RRU MOUNTS ?? REMOVAL OF (3) AT&T PANEL ANTENNAS ?? REMOVAL OF (3) AT&T STACKED PANEL ANTENNAS ?? REMOVAL OF (3) ANTENNA MOUNTS ?? INSTALLATION OF (3) AT&T STACKED PANEL ANTENNAS ?? INSTALLATION OF (6) AT&T PANEL ANTENNAS ?? INSTALLATION OF (12) AT&T REMOTE RADIO UNITS (RRU'S) ?? INSTALLATION OF (6) AT&T RRU BACK TO BACK MOUNTS ?? INSTALLATION OF (6) AT&T CROSS OVER MOUNTS ?? INSTALLATION OF (6) AT&T 2 7 8"x8' VERTICAL MOUNTING PIPES ?? INSTALLATION OF (1) AT&T DC9 SURGE SUPPRESSOR ?? INSTALLATION OF (3) VFA8-HD ANTENNA MOUNTS ?? INSTALLATION OF (1) MSFAA MOUNT ?? REMOVAL OF (6) AT&T COAX LINES ?? INSTALLATION OF (3) 25 AMP BREAKERS FOR 4415 B30 RADIOS ?? INSTALLATION OF (3) 50 AMP BREAKERS FOR AIR6419 B77D RADIOS ?? INSTALLATION OF (3) 50 AMP BREAKERS FOR AIR6419 B77G RADIOS ?? INSTALLATION OF (3) 50 AMP BREAKERS FOR 4890 B25/B66 RADIOS ?? INSTALLATION OF (3) 25 AMP BREAKERS FOR 4478 B14 RADIOS ?? INSTALLATION OF (3) 50 AMP BREAKERS FOR 4490 B5/B12A RADIOS ?? INSTALLATION OF (2) 15 AMP BREAKERS FOR 6651 ?? INSTALLATION OF (1) AT&T DC12-48-60-RM SURGE SUPPRESSOR ?? INSTALLATION OF (1) #6AWG DC TRUNK ?? INSTALLATION OF (3) #6AWG TELCOFLEX CIRCUITS FROM (P) DC12 TO POWER PLANT ?? INSTALLATION OF (2) RECTIFIERS ?? INSTALLATION OF (2) 6651 BBUS ?? INSTALLATION OF (1) 6610 CONTROLLER ?? INSTALLATION OF (1) XMU ?? INSTALLATION OF (1) SAU.

Permit history (15)

Permit history for this parcel — 8 of 15 records
DateRecordWhatStatusValue
2024-06-18expired 2026-04-14TC-UTL-0624-00027City permit recordUtilitiesT533 - 6' to 9' mount and equipment swap on an existing 65' monopole. No height increase or ground disturbance. PROPOSED SITE BUILD OF AN UNMANNED TELECOMMUNICATIONS FACILITY, CONSISTING OF THE FOLLOWING: ?? REMOVAL OF (9) AT&T REMOTE RADIO UNITS (RRU'S) ?? REMOVAL OF (3) AT&T BACK-TO-BACK RRU MOUNTS ?? REMOVAL OF (3) AT&T PANEL ANTENNAS ?? REMOVAL OF (3) AT&T STACKED PANEL ANTENNAS ?? REMOVAL OF (3) ANTENNA MOUNTS ?? INSTALLATION OF (3) AT&T STACKED PANEL ANTENNAS ?? INSTALLATION OF (6) AT&T PANEL ANTENNAS ?? INSTALLATION OF (12) AT&T REMOTE RADIO UNITS (RRU'S) ?? INSTALLATION OF (6) AT&T RRU BACK TO BACK MOUNTS ?? INSTALLATION OF (6) AT&T CROSS OVER MOUNTS ?? INSTALLATION OF (6) AT&T 2 7 8"x8' VERTICAL MOUNTING PIPES ?? INSTALLATION OF (1) AT&T DC9 SURGE SUPPRESSOR ?? INSTALLATION OF (3) VFA8-HD ANTENNA MOUNTS ?? INSTALLATION OF (1) MSFAA MOUNT ?? REMOVAL OF (6) AT&T COAX LINES ?? INSTALLATION OF (3) 25 AMP BREAKERS FOR 4415 B30 RADIOS ?? INSTALLATION OF (3) 50 AMP BREAKERS FOR AIR6419 B77D RADIOS ?? INSTALLATION OF (3) 50 AMP BREAKERS FOR AIR6419 B77G RADIOS ?? INSTALLATION OF (3) 50 AMP BREAKERS FOR 4890 B25/B66 RADIOS ?? INSTALLATION OF (3) 25 AMP BREAKERS FOR 4478 B14 RADIOS ?? INSTALLATION OF (3) 50 AMP BREAKERS FOR 4490 B5/B12A RADIOS ?? INSTALLATION OF (2) 15 AMP BREAKERS FOR 6651 ?? INSTALLATION OF (1) AT&T DC12-48-60-RM SURGE SUPPRESSOR ?? INSTALLATION OF (1) #6AWG DC TRUNK ?? INSTALLATION OF (3) #6AWG TELCOFLEX CIRCUITS FROM (P) DC12 TO POWER PLANT ?? INSTALLATION OF (2) RECTIFIERS ?? INSTALLATION OF (2) 6651 BBUS ?? INSTALLATION OF (1) 6610 CONTROLLER ?? INSTALLATION OF (1) XMU ?? INSTALLATION OF (1) SAUIssued
2023-11-08finaledTF-FCP-1123-01292City permit recordFire ConstructionSwap out existing Generator on existing concrete padComplete
2023-11-08finaledTF-FOP-1123-01747City permit recordFire OperationalOperational Permit for new 30 Kw Diesel GeneratorComplete
2023-09-14expired 2024-09-07TC-COM-0923-02205City permit recordCommercial BuildingSwap out existing Generator with a new 30 kW Diesel Generator on existing concrete pad within existing compoundIssued
2022-08-16expired 2023-08-23T22FC00574City permit recordFire ConstructionFlammable & Combustible Liquid - Emergency generator with diesel belly tank to provide back-up power at cell tower when electric power from the local utility is interrupted.; Other Construction PermitIssued
2022-08-15expired 2023-03-19T22CM06266City permit recordCommercial BuildingTHIS PROJECT WILL BE COMPRISED OF:CHANGES ON THE EXISTING MONOPOLE:· POSITION 3- REMOVE (1) ANTENNIssued
2018-01-12finaledT18CM00334City permit recordCOMBOAT&T REPL ANTENNASFinal
2016-01-15finaledT16CM00399City permit recordCOMBOREPLACEMENT AND INSTALLATION OF ANTENNAFinal
Show 7 older records
Permit history for this parcel — remaining 7 records
DateRecordWhatStatusValue
2012-04-24finaledT12CM02150City permit recordCOMBOREMOVE/INSTALL ANGENNAS & ASSOCIATED EQUIPMENT ON EXISTING FACILITYFinal
2010-09-17finaledT10CM02594City permit recordCOMBOINSTALL HYDROGEN FUEL CELL & STORAGE CABINETFinal
2010-04-20expired 2011-06-10T10CM01060City permit recordCOMBOATTACH ANTENNAS TO AN EXISTING MONOPOLE, INSTALL EQUIPMENT CABINET ON A METAL PLATFORMExpired
2010-01-27completed 2010-01-27T10SE00003Special exceptionZoning Examiner Special ExceptionSE-10-03 - The proposed use is the addition of wireless commuication antenna on an existing 65 foot tall monopole. Associated ground equipment is to be placed inside an existing screened compound. - Antenna colocation on exist'g monopoleSE-10-03Approved
1999-10-15expired 2000-06-06T99CM04901City permit recordCOMBOCELL SITEExpired
1999-06-21P99AN01735City permit recordADDRNEWIssued
1999-06-21T99CM02986City permit recordCOMBOTELE COMMUNICATION FACILITYWithdrwn

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 11012009B — 15 permits on file from 1999 to 2024 (7 combo, 2 fire construction, 2 commercial building, 1 utilities) — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.