Electrical permit history — 4685 E Grant Rd
4685 E Grant Rd, Tucson — built 1997, with 20 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
4685 E Grant Rd
Built 1997 — 1990s commercial stock · HVAC 2018 (finaled)
Permanent link: Electrical permit history for 4685 E Grant Rd (aztucsonelectricalsolutions.com/property/11008305e/4685-e-grant-rd-tucson-az-85712) · Public records last checked 2026-08-17
- Parcel
- 11008305E
- Built
- 1997 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-1
- Assessor use
- Free Standing Drugstore
- Parcel size
- 1.94 acres
- Building area
- 15,608 sq ft (assessor record)
- Sewer
- No connection on file (sewer or septic status not confirmed by the record — verify on site)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2021 firecons permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalCurrentLast permitted 2018 (8 years ago). City inspection record: MECHANICAL - FINAL approved 2018-11-20. Contractor of record: HUSSMANN SERVICES CORPORATION. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. T18CM06732 — REPL HVAC
- Fire alarm & life safetyCurrentLast permitted 2021 (5 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T21FC00339 — REPLACE ANALOG POTS LINES WITH A CELL DIALER FOR FIRE ALARM COMMUNICATIONS
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check
Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
A pool or spa was permitted in 2022. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.
Most recent permit on record for this parcel: 2022-04-11 (T22RW01439) — JOB ORDER CONTRACT (JOC) FOR TRAFFIC SIGNAL & STREET LIGHT CONSTRUCTION, CONTRACT NUMBER 181906-02 REMOVAL OF THE "RED LIGHT RUNNERS" OLD CAMERAS THAT NO LONGER WORK IN THE INTERSECTION OF SWAN RD / GRANT RD. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. OTHER ACTIVITIES IN THE AREA, WILL NEED TO COORDINATE TRAFFIC CONTROL SETUP WITH EXISTING SETUP. BUS STOP IN THE AREA, CONTACT SUN TRAN DISPATCH, AT 520-206-8934 AND/OR BEA PAULUS AT 520-206-8826 AT LEAST 48-BUSINESS HOURS PRIOR TO START OF WORK FOR COORDINATION..
Permit history (20)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2022-04-11finaled | T22RW01439City permit record | Pool / spaJOB ORDER CONTRACT (JOC) FOR TRAFFIC SIGNAL & STREET LIGHT CONSTRUCTION, CONTRACT NUMBER 181906-02 REMOVAL OF THE "RED LIGHT RUNNERS" OLD CAMERAS THAT NO LONGER WORK IN THE INTERSECTION OF SWAN RD / GRANT RD. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. OTHER ACTIVITIES IN THE AREA, WILL NEED TO COORDINATE TRAFFIC CONTROL SETUP WITH EXISTING SETUP. BUS STOP IN THE AREA, CONTACT SUN TRAN DISPATCH, AT 520-206-8934 AND/OR BEA PAULUS AT 520-206-8826 AT LEAST 48-BUSINESS HOURS PRIOR TO START OF WORK FOR COORDINATION. | Final | |
| 2021-05-07finaled | T21FC00339City permit record | FIRECONSREPLACE ANALOG POTS LINES WITH A CELL DIALER FOR FIRE ALARM COMMUNICATIONS | Final | |
| 2018-08-27finaled | T18CM06732City permit record | COMBOREPL HVAC | Final | |
| 2015-07-24expired 2016-02-16 | T15CM05126City permit record | COMBOINSTALL EXTERIOR LIGHTING FIXTURES | Expired | |
| 2013-10-31finaled | T13BU01208City permit record | BUILDSMALL PORTABLE DONATION BIN | Final | |
| 2012-10-12finaled | T12BU01214City permit record | BUILDFIRE ALARM | Final | |
| 2012-09-21finaled | T12BU01114City permit record | SPKLRFIRE SPRINKLER | Final | |
| 2012-05-31finaled | T12CM03122City permit record | COMBOTI: WALGREENS AT GRANT - RETAIL PHARMACY | Final |
Show 12 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2012-04-11finaled | T12OT00575City permit record | Fence / wall13- ILLUM WALL SIGNS N,S,E&W / C OF C ON FP SIGNS | Final | |
| 2011-07-11finaled | T11BU00923City permit record | SPKLRADD 7 FIRE SPRINKLERS. | Final | |
| 2011-06-15expired 2012-02-26 | T11ME00163City permit record | MECHMECHANICAL:REPLACE 5 A/C UNITS ON ROOF | Expired | |
| 2011-04-04finaled | T11CM00964City permit record | COMBOTI: RETAIL | Final | |
| 2010-08-06finaled | T10BU01262City permit record | BUILDSMALL DONATION BIN | Final | |
| 2009-07-01 | T09CM01719City permit record | COMBONEW ELEC CIRCUIT FOR REDBOX DVD VENDING MACHINE | Withdrwn | |
| 2008-04-22finaled | T08OT00960City permit record | SIGN14846 | Final | |
| 2007-11-29finaled | T07OT02694City permit record | SIGN14094 | Final | |
| 2007-07-25expired 2008-02-23 | T07OT01695City permit record | SIGN13441 | Expired | |
| 2006-06-21finaled | T06OT01646City permit record | SIGN11377 | Final | |
| 2004-06-18finaled | T04OT01220City permit record | SIGNSIGN:7332 | Final | |
| 2004-06-17finaled | T04OT01216City permit record | SIGNSIGN:7327 | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (12)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2022-11-02 | CE-VIO1122-00107Code enforcement case | Vegetation | Closed - unfounded |
| 2019-05-16 | T19DV04029Code enforcement case | Vegetation | Noverify |
| 2019-04-09 | T19DV02724Code enforcement case | Code enforcement case | Complian |
| 2014-01-13 | T14DV00235Housing code violation | SIGN VIOLATIONrecorded before 2023 | COMPLIAN |
| 2013-11-22 | T13DV08778Code enforcement case | Sign | Complian |
| 2011-07-12finaled | T11FR01017Code enforcement case | Code enforcement case | Complete |
| 2011-03-15 | T11DV01583Code enforcement case | Sign | Complian |
| 2009-05-28finaled | T09FR01813Code enforcement case | Code enforcement case | Complete |
Show 4 older records
| Date | Record | What | Status |
|---|---|---|---|
| 2009-03-13finaled | T09FR00952Code enforcement case | Code enforcement case | Complete |
| 2008-06-24 | T08DV05356Code enforcement case | Code enforcement case | Referred |
| 2007-07-12finaled | T07FR01317Code enforcement case | Code enforcement case | Complete |
| 2007-02-02 | T07DV01096Code enforcement case | Sign | Complian |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
How this report was built
This is a reading of public records for parcel 11008305E — 20 permits on file from 2004 to 2022 (6 sign, 5 combo, 3 build, 2 spklr) and 12 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.