Electrical permit history — 4515 E Grant Rd

4515 E Grant Rd, Tucson — built 1973, with 64 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Multifamily property

4515 E Grant Rd

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1973 — 1970s multifamily stock · HVAC 2009 (finaled) · 1 open code case

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2011 addition / alteration permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Nothing permitted on the service or distribution shows in the record we read, which for a building of this era leaves the original switchgear generation in play. Obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown — worth establishing what is actually installed before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalLikely dueLast permitted 2009 (17 years ago). The assessor records cooling as WARMED AND COOLED AIR and heating as Forced Air. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Equipment from before about 2010 generally runs R-22, which has not been produced since 2020 — repairs mean reclaimed refrigerant at a price that often exceeds replacing the unit. T08CM03998 — HVAC UPGRADE (BLDG 4)
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records the roof as Composition Shingle. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Worth looking at

    There is an open code enforcement case on this parcel. An open case can hold up a permit, and if it touches unpermitted work the electrical scope usually has to be brought up to code as part of resolving it.

  • Worth confirming

    Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Solar was permitted here in 2011. That means there is an existing interconnection, and the main breaker and busbar rating already carry a PV backfeed — so anything else you add (an EV charger, a heat pump) has to be checked against what is left under the 120% rule, not against the service size alone.

  • Routine

    A trade permit was pulled in 2019. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 136,456 sq ft (county building-footprint layer, 15 structures)
Usable for solar, planning estimate
≈ 95,500 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 1,050 kW — roughly 2,630 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 1,730,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$138,000–$225,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “El Con Mall - Reid Park Area”, is about 1.6 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
11008304E
Year constructed
1973 (assessor record)
Permitting authority
Tucson
Zoning
R-3
Property type
Apartments 100+ Units 2 Story
Building area
193,076 sq ft
Cooling
WARMED AND COOLED AIR
Heating
Forced Air

The building area, cooling and heating above come from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2025. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2025. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 64 building permits for this parcel dated between 1997 and 2025. By category the work is addition / alteration (31), trade permit (11), solar pv (3) and permanent sign (3). 22 of them carry a final inspection; the other 42 were issued, expired or are still open, which is not the same as work completed. There are 58 code-enforcement cases recorded against the parcel, 1 of which is open. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 11008304E. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All multifamily property · Commercial property in 85712 · Commercial & industrial reports · Homes in 85712 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The flood zone shown is FEMA’s National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on E GRANT RD hold 4,180 City permits on record, 956 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (122 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2026CE-VIO0526-02220Code enforcement caseActive
2026CE-VIO0426-01816Code enforcement caseClosed - Unfounded
2025CE-VIO0825-03488RefuseClosed - Resolved
2025TC-COM-0423-01007Commercial Solar PermitIssued
2024TC-UTL-0624-00030Cell Tower Building PermitIssued
2024TC-COM-1024-02006Commercial Addition/Alteration PermitNeeds Resubmittal
2024TC-COM-1024-02005Commercial Addition/Alteration PermitNeeds Resubmittal
2024TC-COM-0523-01181Commercial Solar PermitIssued
2024TC-COM-0924-01797Commercial Addition/Alteration PermitNeeds Resubmittal
2024TC-COM-0924-01796Commercial Addition/Alteration PermitNeeds Resubmittal
2024TC-COM-0924-01795Commercial Addition/Alteration PermitExpired
2024TD-DEV-0924-00252Development PackageExpired
2023CE-VIO1123-06466Code enforcement caseClosed - Resolved
2023TS-PRM-0323-00213Permanent Sign PermitIssued
2022CE-VIO1122-00408RefuseClosed - Unfounded
2022T22DV06016PROP MAINT MULTIPLE TYPESCOMPLIAN
2022T22DV05309REFUSENOVERIFY
2022T22CM05770Commercial Trade PermitIssued
2022T22DV04262REFUSECOMPLIAN
2022T22DV04214RES: MINIMUM HOUSINGCOMPLIAN
2022T22SA00331Zoning ComplianceComplete
2022T22DV03683RES: MINIMUM HOUSINGNOVERIFY
2022T22DV01418RES: MINIMUM HOUSINGCOMPLIAN
2022T22DV01299REFUSENOVERIFY
2021T21DV08951RES: MINIMUM HOUSINGNOVERIFY
2021T21DV08832RES: MINIMUM HOUSINGNOVERIFY
2021T21DV08295WEEDSREFERRED
2021T21DV07476EMERGENCYCOMPLIAN
2021T21DV07479RES: MINIMUM HOUSINGNOVERIFY
2021T21DV07477RES: MINIMUM HOUSINGNOVERIFY
2021T21DV05473REFUSENOVERIFY
2021T21DV04181LIGHTING VIOLATIONCOMPLIAN
2021T21DV01194PROP MAINT MULTIPLE TYPESNOVERIFY
2021T21DV00689RES: MINIMUM HOUSINGCOMPLIAN
2021T21DV00653RES: MINIMUM HOUSINGCOMPLIAN
2021T21DV00339REFUSECOMPLIAN
2021T21DV00209MULTIPLE TYPESREFERRED
2020T20SA00359Zoning ComplianceComplete
2020T20DV06148LIGHTING VIOLATIONCOMPLIAN
2020T20DV05951REFUSENOVERIFY
2020T20DV03348LIGHTING VIOLATIONCOMPLIAN
2020T20DV01461RES: MINIMUM HOUSINGCOMPLIAN
2020T20DV00918LIGHTING VIOLATIONFIELD
2020T20DV00875LIGHTING VIOLATIONNOVERIFY
2019T19DV04813RES: MINIMUM HOUSINGCOMPLIAN
2019T19DV01699EMERGENCYCOMPLIAN
2019T18CM10034Commercial Trade PermitComplete
2018T18DV06946COMMERCIAL ZONINGCOMPLIAN
2018T18DV06669MULTIPLE TYPESFIELD
2018T18DV06677PROP MAINT MULTIPLE TYPESCOMPLIAN
2018T18DV06619RES: MINIMUM HOUSINGREFERRED
2018T18DV06620RES: MINIMUM HOUSINGCOMPLIAN
2018T18DV04698ENVIRONMENTALCOMPLIAN
2018T18CM05257Commercial Addition/Alteration PermitWithdrawn
2018T18DV03692MULTIPLE TYPESCOMPLIAN
2018T18DV02808RES: MINIMUM HOUSINGNOVERIFY
2018T16OT00160Elevation CertificateComplete
2018T18DV00566REFUSENOVERIFY
2018T18DV00518REFUSECOMPLIAN
2018T18DV00134EMERGENCYCOMPLIAN
2017T17DV04820RES: MINIMUM HOUSINGNOVERIFY
2016T16DV04355RES: MINIMUM HOUSINGNOVERIFY
2016T16DV04253ENVIRONMENTALCOMPLIAN
2016T16DV01597PROP MAINT MULTIPLE TYPESCOMPLIAN
2016T16CM00383Commercial Trade PermitComplete
2015T15SE00087Zoning ComplianceApproved
2014T14DV05775SIGN VIOLATIONCOMPLIAN
2014T13CM05911Commercial Addition/Alteration PermitCanceled
2014T13BU01086Commercial Fence/Wall PermitCanceled
2014T14CM00536Commercial Trade PermitComplete
2014T13BU01085Storage Tank PermitCanceled
2013T13DV09370REFUSENOVERIFY
2013T13DV06163RES: MINIMUM HOUSINGCANCEL
2013T13SE00091Mayor Council Special ExceptionCanceled
2013T13DV03765COMMERCIAL ZONINGNOVERIFY
2012T12CM06287Commercial Trade PermitWithdrawn
2012T12TUP0012Temporary Use PermitCanceled
2012T12CM03451Commercial Addition/Alteration PermitWithdrawn
2012T12SE00022Mayor Council Special ExceptionApproved
2011T11DV09516RES: MINIMUM HOUSINGCANCEL
2011T11CM03412Commercial Addition/Alteration PermitComplete
2011T11DV08784REFUSENOVERIFY
2011T11CM03154Residential Solar PermitComplete
2011T11BU00172Commercial Trade PermitCanceled
2011T11CM00244Commercial Addition/Alteration PermitWithdrawn
2010T10DV05784RESIDENTIAL FIRECOMPLIAN
2010T10CM01585Commercial Addition/Alteration PermitComplete
2010T10DV01691WORK WITHOUT PERMITS-RESIDENTLCOMPLIAN
2010T10CM00444Commercial Addition/Alteration PermitComplete
2010T10CM00445Commercial Addition/Alteration PermitComplete
2009T09SE00060Zoning Examiner Special ExceptionCanceled
2009T09PRE0099Pre-Application ConferenceCanceled
2009T09DV04205RESIDENTIAL ZONINGCOMPLIAN
2009T08CM04003Commercial Addition/Alteration PermitCanceled
2009T08CM04005Commercial Addition/Alteration PermitCanceled
2009T08CM04006Commercial Addition/Alteration PermitCanceled
2009T08CM03998Commercial Addition/Alteration PermitComplete
2009T08CM03999Commercial Addition/Alteration PermitCanceled
2009T08CM04000Commercial Addition/Alteration PermitCanceled
2009T08CM04001Commercial Addition/Alteration PermitCanceled
2009T08CM04002Commercial Addition/Alteration PermitCanceled
2009T08CM03995Commercial Trade PermitComplete
2009T08CM03996Commercial Addition/Alteration PermitComplete
2009T08CM03997Commercial Addition/Alteration PermitComplete
2009T08CM04007Commercial Addition/Alteration PermitCanceled
2009T08CM04008Commercial Addition/Alteration PermitCanceled
2009T08CM04009Commercial Addition/Alteration PermitCanceled
2009T08CM04010Commercial Addition/Alteration PermitCanceled
2009T08CM04011Commercial Addition/Alteration PermitCanceled
2009T09OT00087Floodplain Use PermitCanceled
2009T09OT00088Floodplain Use PermitCanceled
2008T08DV01830SIGN VIOLATIONCOMPLIAN
2007T07DV09603Permanent Sign PermitComplete
2006S06-120 Subdivision/PlatsCanceled
2002T02ME00343Commercial Trade PermitComplete
2002T02PL00916Commercial Trade PermitComplete
2000T00PL01332Commercial Trade PermitComplete
2000T99BU02262Commercial Addition/Alteration PermitComplete
1999T99CM03078Commercial Addition/Alteration PermitCanceled
1999T99VL00102Permanent Sign PermitComplete
1998T98ME00923Commercial Trade PermitComplete
1997T97BU01401Commercial Addition/Alteration PermitWithdrawn

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 11008304E — 64 City permits on file from 1997 to 2025 and 58 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area, cooling, heating, roof, walls on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-09-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.