Electrical permit history — 2590 N Alvernon Wy

2590 N Alvernon Wy, Tucson — built 1947, with 20 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

2590 N Alvernon Wy

Built 1947 — 1940s commercial stock · 20 permits on record; no permitted panel/service or HVAC work among them

Parcel
110074110
Built
1947 (county record)
Jurisdiction
Tucson
Zoning
O-3
Assessor use
Office Building 1 Story
Parcel size
1.39 acres
Building area
12,950 sq ft (assessor record)
Sewer
Connection on file (2020) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 2590 N Alvernon Wy, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2021 row permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2021 row permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentLast permitted 2020 (6 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T20FC00508 — New fire sprinkler system.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Routine

    Office and medical tenant improvements are usually limited by available panel spaces and branch circuit capacity, not by the service itself.

Recorded sales (1)

Recorded transfers from the Pima County Assessor — 1 of 1
DatePriceType
1998-04-14$567,450Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2021-01-05 (T21RW00028) — W/O# 2017313 - TAKING OUT 8 FT SIDEWALK AND DIG TO REPLACE FIRE HYUDRANT AND BACK FILL WITH CLEAN FILL DIRT/AB DO TEMP PATACH ON THE SIDEWALK. A LANE SHIFT AND CLOSING THE SIDEWALK FOR THE SAFETY OF WORKERS..

Permit history (20)

Permit history for this parcel — 8 of 20 records
DateRecordWhatStatusValue
2021-01-05finaledT21RW00028City permit recordROWW/O# 2017313 - TAKING OUT 8 FT SIDEWALK AND DIG TO REPLACE FIRE HYUDRANT AND BACK FILL WITH CLEAN FILL DIRT/AB DO TEMP PATACH ON THE SIDEWALK. A LANE SHIFT AND CLOSING THE SIDEWALK FOR THE SAFETY OF WORKERS.Final
2020-12-21finaledT20RW06596City permit recordROWSTARTING ON THE SOUTH/EAST SIDE OF CROW CREEK LN, PLACE 3x3 POTHOLE TO PLACE NEW PEDESTAL. WORK LOCATION IS ON E FLOWER STREET.Final
2020-11-30finaledT20RW06333City permit recordROWN.811075- ALONG E. FLOWER ST. EAST OF N. ALVERNON WAY MAKE 2'X4' SPLICE PIT TO ACCESS EXISTING CONDUIT. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION. MAINTAIN PEDESTRIAN ACCESSFinal
2020-09-11expired 2021-03-10T20OT00626City permit recordFence / wall3-ILLUM WALL SIGNSExpired
2020-09-03finaledT20RW04898City permit recordROWINSTALLATING A 4" FIRE PROTECTION SERVICE FOR 2590 N ALVERNON WY ON FLOWER AV.Final
2020-07-31finaledT20FC00508City permit recordFIRECONSNew fire sprinkler system.Final
2020-07-28finaledT20FC00499City permit recordFIRECONSNEW COMMERCIAL OFFICE BUILDINGFinal
2020-06-18finaledT20RW03486City permit recordFence / wallOUR FAMILY SERVICES, DP19-0284 PLACE CONSTRUCTION FENCE NEXT TO CURB ALONG FLOWER STREET. INSTALL 200’ X 5’ W SIDEWALK AND NEW 25’ ENTRANCE. ALSO, INSTALL WATER LINE FOR FIRE SERVICE, TRENCH 10’ L X 4’ D X 2’W. THE TYPE 1 SIDEWALK SCUPPER ON FLOWER STREET SHALL EXTEND FROM PROPERTY LINE TO CURB AS SHOWN ON PAG STANDARD DETAIL 204. OTHER ACTIVITIES IN THE AREA, WILL NEED TO COORDINATE TRAFFIC CONTROL SETUP WITH EXISTING SETUP.Final
Show 12 older records
Permit history for this parcel — remaining 12 records
DateRecordWhatStatusValue
2020-06-09finaledT20FC00383City permit recordFIRECONSNew System - For Sprinkler Monitoring & NotificationFinal
2020-03-03expired 2020-09-14T20OT00202City permit recordFloodplain UseFUP FOR DP19-0284Issued
2020-02-27finaledT20RW01254City permit recordROW2 5X5 BELLHOLES IN DIRT/BLKTOP FRONT AND APPROX 15 FT TRENCH - TO PERM ABANDON GAS LINEFinal
2020-01-30finaledT20CM00704City permit recordCOMBOE - NEW OFFICE BUILDINGC of o
2020-01-10finaledT20BU00016City permit recordDEMODEMO BUILDINGFinal
2019-11-14expires 2026-10-17DP19-0284City permit recordNew constructionSITE/GRADING - Our Family Svcs, demo existing building and build new building.Issued
2017-05-23finaledT17RW02224City permit recordROWTEP REPLACING EXISTING POLES (2) AND OVERHEAD EQUIPMENT WORK IS OFF FLOWER STFinal
2016-11-29expired 2017-01-12T16RW02964City permit recordROWREPLACING EXISTING POLES (2) AND OVERHEAD EQUIPMENTExpired
2012-07-11expired 2014-01-29T12OT01036City permit recordSIGNREMOVE OLD DF / REPLACE WITH NEW 20592Expired
2008-07-25finaledT08EL01398City permit recordELECTELECTRIC CABINETFinal
2006-08-18finaledT06OT02161City permit recordSIGN11668Final
1997-05-14finaledT97PL00514City permit recordPLUMBGAS REPIPEFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (2)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 2 of 2 records
DateRecordWhatStatus
2013-11-22T13DV08776Code enforcement caseSignComplian
2006-07-20T06VL00930Code enforcement caseSignComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 110074110 — 20 permits on file from 1997 to 2021 (7 row, 3 firecons, 2 fence / wall, 2 sign) and 2 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.