Electrical permit history — 2732 N Alvernon Wy
2732 N Alvernon Wy, Tucson — built 2003, with 33 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
2732 N Alvernon Wy
Built 2003 — 2000s commercial stock · last permitted panel/service work 2007 (finaled)
Permanent link: Electrical permit history for 2732 N Alvernon Wy (aztucsonelectricalsolutions.com/property/110072620/2732-n-alvernon-wy-tucson-az-85712) · Public records last checked 2026-08-17
- Parcel
- 110072620
- Built
- 2003 (county record)
- Jurisdiction
- Tucson
- Zoning
- O-2
- Assessor use
- Medical Dental Service
- Parcel size
- 1.66 acres
- Building area
- 16,327 sq ft (assessor record)
- Sewer
- Connection on file (2003, 2008) (county sewer connection records)
- Flood zone
- X (shaded) — 0.2% annual-chance flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
- Service on record
- City records show the 2007 permit was finalized; the permit description states “Install 48' of new 4" fire service underground pipe”.
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionCurrentLast permitted 2007 (19 years ago). City inspection record: last recorded inspection 2008-04-25; no approved final is shown. Contractor of record: CUTLER FIRE PROTECTION INC ,. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T07BU01748 — Install 48' of new 4" fire service underground pipe
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2024 fire construction permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyCurrentLast permitted 2024 (2 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0824-00650 — Modify existing wet pipe fire sprinkler system
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Routine
Office and medical tenant improvements are usually limited by available panel spaces and branch circuit capacity, not by the service itself.
Recorded sales (2)
| Date | Price | Type |
|---|---|---|
| 2002-08-30 | $459,500 | Special Warranty Deed |
| 1998-10-05 | $230,000 | Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2026-06-08 (TR-ROW-0626-00692) — EMERGENCY, DONE AFTER THE FACT. The contractor will be rewiring the intersection for Armando Barcamonte for the City of Tucson. Request--Traffic control 6:00am to 6:00pm..
Permit history (33)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2026-06-08finaled | TR-ROW-0626-00692City permit record | Right-of-Way (ROW)EMERGENCY, DONE AFTER THE FACT. The contractor will be rewiring the intersection for Armando Barcamonte for the City of Tucson. Request--Traffic control 6:00am to 6:00pm. | Complete | |
| 2025-06-12 | TC-COM-0625-01148City permit record | Addition / alterationSPECIALIST IN DERMATOLOGY - ALTERATION TO EXISTING ROOMS 129, 144, 146, AND 150 | Expired | |
| 2024-08-09finaled | TF-FCP-0824-00650City permit record | Fire ConstructionModify existing wet pipe fire sprinkler system | Complete | |
| 2024-02-08 | TE-FPU-0224-00039City permit record | Floodplain UseRENOVATIONS TO SPECIALIST IN DERMATOLOGY OFFICE BUILDING, NEW EXAM ROOMS | Issued | |
| 2023-10-17finaled | TC-COM-1023-02443City permit record | Commercial BuildingTI-SPECIALIST IN DERMATOLOGY OFFICE BUILDING Convert Office room 225 to New Exam Rooms 101,102,103,104,105,106 & REV1: Convert 214, for use as SRT, Superficial Radiation Therapy Room. | Inspections complete | |
| 2022-10-06finaled | T22OT00727City permit record | Fence / wall2-illum wall signs | Complete | |
| 2022-09-13finaled | T22RW03337City permit record | Right-of-Way (ROW)WO 1475253 REPAIR LEAKING SERVICE ON THE WEST SIDE OF THE LOT IN ROAD AND DIRT** PROOF OF NOTIF; Work Order: 1475253 | Complete | |
| 2020-10-21 | T20OT00718City permit record | Floodplain UseFUP for T20CM07017 | Approved |
Show 25 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2020-10-13expired 2023-10-20 | T20CM07017City permit record | Commercial BuildingINTERIOR REMODEL | Expired | |
| 2018-10-08finaled | T18RW04538City permit record | ROW18R3096 8 LF north side of the lot on glenn approx 100ft east of alvernon repair leaking water main Emergency crew is on site | Final | |
| 2018-08-07finaled | T18RW03543City permit record | Addition / alterationSEWER REHABILIATION, NO EXCAVATION ADDITIONAL PLANS FOR SAME JOB, 2600 N ALVERNON & 2725 N ALVERNON WAY ADDRESS ON APPLICATION-3901 N GLENN 09/27/18 - PLAN ADD/CHANGE 24 HOUR CENTERLANE CLOSURE FOR BYPASS SETUP ON NORTH ALVERNON WAY FROM EAST GLENN STREET TO EAST GRANT ROAD. | Final | |
| 2017-12-14expired 2018-01-17 | T17RW05520City permit record | ROWMANHOLE ACCESS FOR UTILITY LOCATES ALVERNON WAY & GLENN | Expired | |
| 2008-06-24finaled | T08OT01491City permit record | SIGN15186 | Final | |
| 2008-01-08expired 2008-03-08 | T08EX00023City permit record | EXCAVEXCA:TWO 2'X2' IN DIRT TO PLACE TWO ANCHORS | Closed | |
| 2007-10-29finaled | T07BU02292City permit record | SPKLRInstall 48' of 4" underground & 87 fire sprinklers | Final | |
| 2007-08-17finaled | T07BU01748City permit record | SPKLRInstall 48' of new 4" fire service underground pipe | Final | |
| 2007-07-12finaled | T07OT01605City permit record | FLOODPLNFLOODPLAIN USE PERMIT | Final | |
| 2007-07-06finaled | T07OT01560City permit record | SIGN13372 | Final | |
| 2007-05-16finaled | T07CM02057City permit record | Addition / alterationADDITION:MEDICAL OFFICE | C of o | |
| 2007-05-16finaled | T07CM02058City permit record | Addition / alterationADDITION:CARPORTS | Final | |
| 2004-02-19 | DS04-04City permit record | Zoning Verification LetterCOFFEE-X-CHANGE - DSMR 04-04 2721 East Speedway Blvd. | Approved | |
| 2004-01-29finaled | T04OT00193City permit record | SIGNSIGN:6658 | Final | |
| 2004-01-23 | DS04-03City permit record | Zoning Verification LetterEastside Research/Comm Ctr - DSMR 04-03 8080 & 8100 E. Research Court | Approved | |
| 2004-01-13 | DS04-02City permit record | Zoning Verification LetterSPECIALISTS IN DERMATOLOGY - DSMR 04-02 2732 NORTH ALVERNON WAY | Approved | |
| 2003-11-12expired 2004-04-17 | T03EX01170City permit record | EXCAVEXCAV:40 LF UTILITY TRENCH | Closed | |
| 2003-10-03finaled | T03BU02553City permit record | SPKLRFIRE SPKR:ADD 103 | Final | |
| 2003-09-17finaled | T03BU02382City permit record | SPKLRFIRE SPKR:INSTALL 210LF OF 4" | Final | |
| 2003-08-20expired 2003-10-19 | T03EX00912City permit record | EXCAVEXCAV:TRENCH 22'P & 22'D FOR FIRE SERVICE & WATER | Closed | |
| 2003-06-04expired 2004-07-31 | T03BU01482City permit record | GRADINGGRADING:CUT 330 FILL 990 | Closed | |
| 2003-06-04finaled | T03CM02752City permit record | COMBONEW:OFFICE BUILDING | C of o | |
| 2003-06-04finaled | T03OT01002City permit record | FLOODPLNFLOODPLAIN USE PERMIT | Final | |
| 2003-03-12expired 2007-06-29 | D03-0009City permit record | Development PackageSPECIALISTS IN DERMATOLOGY6/9/2003 1st approval12/29/2003 1st revision | Approved | |
| 2003-01-13 | T03AN00035City permit record | ADDRNEW | Issued |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (6)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2025-08-14 | CE-VIO0825-03460Code enforcement case | Vegetation | Closed - resolved |
| 2024-05-28 | CE-VIO0524-02007Code enforcement case | Code enforcement case | Closed - unfounded |
| 2019-04-23 | T19DV03248Code enforcement case | Code enforcement case | Noverify |
| 2015-11-02 | T15DV08429Code enforcement case | Code enforcement case | Noverify |
| 2006-06-28 | T06VL00846Code enforcement case | Code enforcement case | Complian |
| 2005-11-23finaled | T05FR01846Code enforcement case | Code enforcement case | Complete |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
How this report was built
This is a reading of public records for parcel 110072620 — 33 permits on file from 2003 to 2026 (4 addition / alteration, 4 spklr, 3 sign, 3 excav) and 6 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.