Electrical permit history — 3916 E Fort Lowell Rd
3916 E Fort Lowell Rd, Tucson — built 1960, with 17 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
3916 E Fort Lowell Rd
Built 1960 — 1960s commercial stock · last permitted panel/service work 2004 (finaled)
Permanent link: Electrical permit history for 3916 E Fort Lowell Rd (aztucsonelectricalsolutions.com/property/11006018a/3916-e-fort-lowell-rd-tucson-az-85712) · Public records last checked 2026-08-16
- Parcel
- 11006018A
- Built
- 1960 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-1
- Assessor use
- Misc Commercial
- Parcel size
- 0.18 acres
- Building area
- 1,560 sq ft (assessor record)
- Sewer
- Connection on file (2009) (county sewer connection records)
- Flood zone
- AH — Special Flood Hazard Area (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
- Service on record
- City records show the 2004 permit was finalized; the permit description states “UPGRADE:ELECTRIC 100AMP TO 200AMP (APA)” — an increase in capacity as described, not a confirmed installed rating.
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionCurrentLast permitted 2004 (22 years ago). City inspection record: ELECTRIC - FINAL approved 2004-03-18. Contractor of record: B W ELECTRIC *T. The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T04EL00456 — UPGRADE:ELECTRIC 100AMP TO 200AMP (APA)
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
Recorded sales (2)
| Date | Price | Type |
|---|---|---|
| 2003-12-19 | $197,035 | Warranty Deed |
| 2002-07-10 | $220,000 | Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2025-10-07 (TE-FPU-1025-00378) — 2 5x5 bellholes in dirt for crews to install gas anodes.
Permit history (17)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2025-10-07expired 2026-01-05 | TE-FPU-1025-00378City permit record | Floodplain Use2 5x5 bellholes in dirt for crews to install gas anodes | Issued | |
| 2025-10-01finaled | TR-UTL-1025-01699City permit record | Right-of-Way (ROW) - Utility2 5x5 bellholes in dirt for crews to install gas anodes | Complete | |
| 2015-05-13expired 2015-07-12 | T15EX00957City permit record | EXCAV25' X 6' X 10' EXCAVATION TO REPAIR DAMAGED PORTION OF EXISTING SEWER LINE | Expired | |
| 2015-05-13 | T15TC01180City permit record | BARRICAD25' X 6' X 10' EXCAVATION TO REPAIR DAMAGED PORTION OF EXISTING SEWER LINE | Expired | |
| 2015-02-09finaled | T15CM00843City permit record | COMBOOFFICE | C of o | |
| 2015-02-09finaled | T15CM00844City permit record | COMBOCHURCH | C of o | |
| 2015-01-23finaled | T15OT00105City permit record | FLOODPLNFPUP TI: CHURCH ASSEMBLY - T14DV00918 | Final | |
| 2015-01-23finaled | T15OT00106City permit record | FLOODPLNFPUP TI: OFFICE - T14DV00918 | Final |
Show 9 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2015-01-22expired 2015-07-22 | T15CM00457City permit record | COMBOTI: INTERIOR FIRE DEMO | Expired | |
| 2015-01-22expired 2015-07-22 | T15CM00458City permit record | COMBOTI: INTERIOR DEMO | Expired | |
| 2015-01-09expired 2015-07-13 | T15CM00160City permit record | Electrical reconnectELECTRICAL RECONNECT | Expired | |
| 2009-10-23 | T09OT02278City permit record | FLOODPLNFLOODPLAIN USE PERMIT- TI: OFFICE | Issued | |
| 2009-10-07finaled | T09CM02710City permit record | COMBOTI AND C OF O :SALON | C of o | |
| 2009-10-07 | T09OT02160City permit record | Pool / spaC OF O:HAIR SALON & DAY SPA | Withdrwn | |
| 2008-09-23 | T08OT02271City permit record | C-OF-OC OF O: NAIL SALON | Withdrwn | |
| 2007-06-25 | T07OT01466City permit record | Pool / spaC OF O:SPA/BEAUTY PARLOR | Withdrwn | |
| 2004-03-04finaled | T04EL00456City permit record | ELECTUPGRADE:ELECTRIC 100AMP TO 200AMP (APA) | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (4)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2020-08-07 | T20DV05473Code enforcement case | Code enforcement case | Referred |
| 2014-02-18 | T14DV00918Code enforcement case | Fire | Complian |
| 2009-11-13finaled | T09FR03529Code enforcement case | Code enforcement case | Complete |
| 2008-09-29finaled | T08FR03250Code enforcement case | Code enforcement case | Complete |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, once. No list, no follow-up unless you ask for it.
How this report was built
This is a reading of public records for parcel 11006018A — 17 permits on file from 2004 to 2025 (5 combo, 3 floodpln, 2 pool / spa, 1 floodplain use) and 4 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.