Electrical permit history — 4620 E Camp Lowell Dr
4620 E Camp Lowell Dr, Tucson — built 2005, with 27 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
4620 E Camp Lowell Dr
Built 2005 — 2000s commercial stock · last permitted panel/service work 2012 (finaled)
Permanent link: Electrical permit history for 4620 E Camp Lowell Dr (aztucsonelectricalsolutions.com/property/11005314e/4620-e-camp-lowell-dr-tucson-az-85712) · Public records last checked 2026-08-16
- Parcel
- 11005314E
- Built
- 2005 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-1
- Assessor use
- Medical Clinic
- Parcel size
- 1.42 acres
- Building area
- 16,602 sq ft (assessor record)
- Sewer
- No connection on file (sewer or septic status not confirmed by the record — verify on site)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
- Service on record
- City records show the 2012 permit was finalized; the permit description states “Install 38' of new 4" fire service underground”.
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionCurrentLast permitted 2012 (14 years ago). City inspection record: FIRE SPKLR - FINAL approved 2012-06-28. Contractor of record: CUTLER FIRE PROTECTION INC ,. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T12BU00778 — Install 38' of new 4" fire service underground
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyCurrentLast permitted 2012 (14 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T12BU01117 — FIRE ALARM
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Routine
Office and medical tenant improvements are usually limited by available panel spaces and branch circuit capacity, not by the service itself.
Recorded sales (2)
| Date | Price | Type |
|---|---|---|
| 2004-07-02 | $3,766,847 | Deed |
| 2003-10-07 | $600,000 | Special Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2026-05-28 (TZ-CMP-0526-00097) — ZVL.
Permit history (27)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2026-05-28 | TZ-CMP-0526-00097City permit record | Zoning Verification LetterZVL | Approved | |
| 2025-09-12finaled | TF-FOP-0925-01213City permit record | Fire OperationalCAMP LOWELL SURGERY CENTER | Complete | |
| 2025-09-12finaled | TF-FOP-0925-01214City permit record | Fire OperationalSurgery Center | Complete | |
| 2025-09-12finaled | TF-FOP-0925-01215City permit record | Fire OperationalSURGERY CENTER | Complete | |
| 2025-05-05expired 2026-01-06 | TC-COM-0525-00905City permit record | Commercial BuildingAdding 800 amp service to building to power portable/temporary humidifiers | Inspections | |
| 2024-09-09finaled | TF-FOP-0924-01020City permit record | Fire OperationalSurgery Center | Complete | |
| 2024-09-09finaled | TF-FOP-0924-01022City permit record | Fire OperationalSurgery Center | Complete | |
| 2024-09-09finaled | TF-FOP-0924-01023City permit record | Fire OperationalSurgery Center | Complete |
Show 19 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2023-09-11finaled | TF-FOP-0923-01485City permit record | Fire OperationalSurgery Center | Complete | |
| 2023-09-11finaled | TF-FOP-0923-01486City permit record | Fire OperationalSurgery Center | Complete | |
| 2023-09-06finaled | TF-FOP-0923-01465City permit record | Fire OperationalAmbulatory Surgery Center | Complete | |
| 2022-07-27finaled | T22FO00645City permit record | FIREOPERCAMP LOWELL SURGERY CENTER | Final | |
| 2019-01-22finaled | T19CM00409City permit record | COMBOELECTRICAL REVISION | Final | |
| 2017-12-28finaled | T17FO01102City permit record | FIREOPEROutpatient Surgical Center | Final | |
| 2016-09-12expired 2016-10-12 | T16RW01475City permit record | ROW4LF IN FRONT OF SIDEWALK AREA FOR 2-SERVICE RENEWALS WORK ORDER # 1613831 | Expired | |
| 2016-04-13finaled | T16EX01261City permit record | EXCAVLANE CLOSURE TO BE ABLE TO PULL OLD POLES AT CORNER IN FRONT OF ADDRESS | Final | |
| 2016-04-13finaled | T16TC00888City permit record | BARRICADLANE CLOSURE TO BE ABLE TO PULL OLD POLES AT CORNER IN FRONT OF ADDRESS | Final | |
| 2012-09-24finaled | T12BU01117City permit record | BUILDFIRE ALARM | Final | |
| 2012-06-19finaled | T12BU00778City permit record | SPKLRInstall 38' of new 4" fire service underground | Final | |
| 2012-06-15expired 2013-03-20 | T12OT00886City permit record | SIGN90 DAY BANNER 6/18-12 TO 9/19/12 | Expired | |
| 2012-06-12finaled | T12BU00741City permit record | SPKLRAdd 12, relocate 14 fire sprinklers, new stub in | Final | |
| 2012-03-19finaled | T12CM01196City permit record | Addition / alteration1,100 S.F. ADDITION PLUS 1,200 S.F. RENOVATION SURGERY CENTER | C of o | |
| 2012-02-21finaled | DP12-0022City permit record | Addition / alterationSITE FOR 1200 SF ADDITION TO MEDICAL CENTER | Complete | |
| 2006-02-23expired 2008-09-16 | T06OT00523City permit record | SIGN10695 | Expired | |
| 2005-12-14finaled | T05OT03099City permit record | SIGN10252 | Final | |
| 2005-09-16finaled | T05BU02301City permit record | SPKLRFIRE SPKR: 60'-4" UNDERGROUND PIPE 188"-6" UNDERGROUND PIPE | Final | |
| 2005-04-25 | T05AN00432City permit record | ADDRNEW | Issued |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (5)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2024-04-25 | CE-VIO0424-01503Code enforcement case | Vegetation | Referred |
| 2010-09-20finaled | T10FR01941Code enforcement case | Fire | Complete |
| 2009-09-30finaled | T09FR03120Code enforcement case | Fire | Complete |
| 2008-09-12finaled | T08FR02763Code enforcement case | Fire | Complete |
| 2007-07-30 | T07DV07007Code enforcement case | Vegetation | Invalid |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Send: the permanent link and the summary above, once. Watch: one email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list either way.
How this report was built
This is a reading of public records for parcel 11005314E — 27 permits on file from 2005 to 2026 (9 fire operational, 3 spklr, 3 sign, 2 fireoper) and 5 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.