Electrical permit history — 3950 E Paradise Falls Dr

3950 E Paradise Falls Dr, Tucson — built 2006, with 36 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

3950 E Paradise Falls Dr

Built 2006 — 2000s commercial stock · 36 permits on record; no permitted panel/service or HVAC work among them

Parcel
110034830
Built
2006 (assessor record)
Jurisdiction
Tucson
Zoning
SR
Assessor use
State School Prop
Parcel size
9.99 acres
Building area
40,604 sq ft (assessor record)
Sewer
Connection on file (2008) (county sewer connection records)
Flood zone
X (shaded) — 0.2% annual-chance flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 3950 E Paradise Falls Dr, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2014 solar pv permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2014 solar pv permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyLikely dueLast permitted 2005 (21 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T05BU00867 — FIRE SPKR: 45 NEW & UNDERGROUND PIPE 95'-4'
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Solar was permitted here in 2014. That means there is an existing interconnection, and the main breaker and busbar rating already carry a PV backfeed — so anything else you add (an EV charger, a heat pump) has to be checked against what is left under the 120% rule, not against the service size alone.

Most recent permit on record for this parcel: 2019-07-12 (T19RW03904) — BORE 738' OF NEW CONDUIT AND PLACE 176' OF NEW AERIAL FUTUREPATH. THE BORE AND AERIAL PLACEMENT CONTINUE OUTSIDE OF CITY ROW. ADDRESS ON APPLICATION: 3904 E KLEINDALE RD.

Permit history (36)

Permit history for this parcel — 8 of 36 records
DateRecordWhatStatusValue
2019-07-12finaledT19RW03904City permit recordROWBORE 738' OF NEW CONDUIT AND PLACE 176' OF NEW AERIAL FUTUREPATH. THE BORE AND AERIAL PLACEMENT CONTINUE OUTSIDE OF CITY ROW. ADDRESS ON APPLICATION: 3904 E KLEINDALE RDFinal
2014-10-20finaledT14CM07051City permit recordSolar PVINSTALL SOLAR TUSD SCHOOLL of c
2013-02-06expired 2013-04-07T13EX00136City permit recordEXCAVTRENCH 560' & PLACE HANDHOLE FOR TUSD FIBER OPTIC..... (APA)Closed
2013-01-25expired 2013-03-26T13EX00085City permit recordEXCAVTRENCH 560' & PLACE HANDHOLE FOT TUSD FIBER OPTIC IMPROVEMENT ** PRIOR TO START OF CONSTRUCTION PLEASE CALL CITY OF TUCSON PERMITS AND CODES INSPECTOR PAT W. AT 400-7064 TO ARRANGE FOR PRE-CONSTRUCTION MEETING.Closed
2011-06-14finaledT11CM01873City permit recordAddition / alterationADDITION: COMMUNITY GARDEN -RAMADA & SHEDFinal
2008-12-11expired 2009-02-09T08EX00978City permit recordEXCAVRepair/replace damaged sidewalkClosed
2008-02-01finaledT08CM00353City permit recordCOMBOALL NEW NATURAL RESOURCES PARK AT DAVISON ELEMENTARY SCHOOL INCLUDING 3 PREFAB RAMADAS REVISION 1: REVISION 2: RAMP TO PLAY GROUND EQUIPMENT REVISION 3: ELECTRICALFinal
2006-07-17finaledT06CM04165City permit recordCOMBOINST: PHOTOVOLTAIC PANEL SYSFinal
Show 28 older records
Permit history for this parcel — remaining 28 records
DateRecordWhatStatusValue
2006-07-17finaledT06CM04167City permit recordCOMBOINST: PHOTOVOLTAIC SYSFinal
2006-07-17finaledT06CM04168City permit recordCOMBOINST: PHOTOVOLTAIC SYSFinal
2005-09-22finaledT05BU02356City permit recordBUILDFIRE: ALARMFinal
2005-09-12finaledT05BU02248City permit recordBUILD2 PRE-ENGINEERED RAMADAS 20' X 20' EACHFinal
2005-04-13finaledT05BU00867City permit recordSPKLRFIRE SPKR: 45 NEW & UNDERGROUND PIPE 95'-4'Final
2005-04-13finaledT05BU00868City permit recordSPKLRFIRE SPKR: 58 NEW ADD UNDERGROUND PIPE 5'-4"Final
2005-04-13finaledT05BU00869City permit recordSPKLRFIRE SPKR: 8 NEW ADD: UNDERGROUND PIPE 35'-4"Final
2005-04-13finaledT05BU00870City permit recordSPKLRFIRE SPKR: 35 NEW ADD: UNDERGROUND PIPE 70'-4"Final
2005-04-13finaledT05BU00871City permit recordSPKLRFIRE SPKR: 49 NEW ADD: UNDERGROUND PIPE 5'-4"Final
2005-04-13finaledT05BU00872City permit recordSPKLRFIRE SPKR: 35 NEW ADD UNDERGROUND PIPE 200'-4"Final
2005-04-13finaledT05BU00873City permit recordSPKLRFIRE SPKR: 8 NEW ADD UNDERGROUND PIPE 35'-4"Final
2005-04-13finaledT05BU00874City permit recordSPKLRFIRE SPKR: 28 NEW ADD UNDERGROUND PIPE 40'-4"Final
2005-04-13finaledT05BU00875City permit recordSPKLRFIRE SPKR: 104 NEW ADD UNDERGROUND PIPE 260'-4"Final
2005-03-16expired 2005-05-15T05EX00306City permit recordEXCAVEXCAV:TRENCH 60LFP & 150LF DClosed
2005-01-19finaledT05PL00110City permit recordPLUMBPRIVATE:SEWERFinal
2005-01-07expired 2005-10-01T05BU00049City permit recordTEMP-FBBTEMP FBB PERMIT W/ELECTRICExpired
2004-12-16finaledT04CM05432City permit recordCOMBONEW SCHOOL - UTILITY NORTH BLDG #3C of o
2004-12-16finaledT04CM05433City permit recordCOMBONEW SCHOOL - ADMIN BLDG #2C of o
2004-12-16finaledT04CM05434City permit recordCOMBONEW SCHOOL - LRC BLDG #1C of o
2004-12-16finaledT04CM05435City permit recordCOMBONEW SCHOOL - MPR BLDG #9C of o
2004-12-16finaledT04CM05436City permit recordCOMBONEW SCHOOL - PRIMARY NORTH BLDG #6C of o
2004-12-16finaledT04CM05438City permit recordCOMBONEW SCHOOL - PRIMARY SOUTH BLDG# 8C of o
2004-12-16finaledT04CM05439City permit recordCOMBONEW SCHOOL - UTILITY SOUTH BLDG #7C of o
2004-12-16finaledT04CM05440City permit recordCOMBONEW SCHOOL - KINDERGARTEN BLDG #5C of o
2004-10-26finaledT04OT02144City permit recordFLOODPLNFLOODPLAIN USE PERMITFinal
2004-09-09finaledT04BU02233City permit recordGRADINGGRADING:3500CY CUT & FILL 13000CY BOND RELEASE PER BETH G 11/15/06Final
2004-09-09finaledT04CM04073City permit recordCOMBONEW SCHOOL - INTERMEDIATE BUILDING #4C of o
2004-08-31T04AN00835City permit recordADDRNEWIssued

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (1)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 1 of 1 records
DateRecordWhatStatus
2009-04-14T09DV01979Code enforcement caseCode enforcement caseNoverify

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 110034830 — 36 permits on file from 2004 to 2019 (13 combo, 9 spklr, 4 excav, 2 build) and 1 code enforcement case — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.