Electrical permit history — 3636 N Craycroft Rd

3636 N Craycroft Rd, Tucson — built 2012, with 13 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

3636 N Craycroft Rd

Built 2012 — 2010s commercial stock · HVAC 2025 (finaled)

Parcel
109224440
Built
2012 (assessor record)
Jurisdiction
Tucson
Zoning
PAD-22
Assessor use
Convenience Store With Fuel Dispensing
Parcel size
2.09 acres
Building area
5,618 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 3636 N Craycroft Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 fire construction permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalCurrentLast permitted 2025 (1 year ago). City inspection record: COT - FCON - Fire - Final approved 2026-05-12. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. TC-COM-0725-01364 — Remove and Replace existing tea and fountain equipment and chiller. Existing C02 to remain. There are no modification to exterior walls, parking, sidewalks or landscape.
  • Fire alarm & life safetyCurrentLast permitted this year (2026). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0226-00082 — Installation of commercial kitchen hood fire suppression system
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    A capacity and condition review is the usual starting point before any tenant improvement or added load. The permit record does not confirm this; an on-site inspection is required.

Most recent permit on record for this parcel: 2026-06-25 (TC-COM-0626-00961) — Solar photovoltaic energy generation system on fuel island canopy, including trenching to back exterior wall of store for feeder conductors to utility line side interconnection.

Permit history (13)

Permit history for this parcel — 8 of 13 records
DateRecordWhatStatusValue
2026-06-25TC-COM-0626-00961City permit recordSolar PVSolar photovoltaic energy generation system on fuel island canopy, including trenching to back exterior wall of store for feeder conductors to utility line side interconnectionNeeds resubmittal
2026-02-08finaledTF-FCP-0226-00082City permit recordFire ConstructionInstallation of commercial kitchen hood fire suppression systemComplete
2026-01-05finaledTC-COM-0126-00010City permit recordAddition / alterationIncludes reorganization of existing kitchen equipment and addition of new fryer units. The existing type 1 hood and wrapped ducts will be replaced with Type 1 new equipment. Rooftop equipment will remain existing.Complete
2025-07-15finaledTC-COM-0725-01364City permit recordFence / wallRemove and Replace existing tea and fountain equipment and chiller. Existing C02 to remain. There are no modification to exterior walls, parking, sidewalks or landscape.Inspections complete
2025-02-17finaledTC-COM-0225-00331City permit recordCommercial BuildingCoffee Wow Phase 2: Updated equipment and millwork to existing coffee bar. Installation of new drain manifold serving the coffee bar. Added dedicated water line and circuit for coffee wow auto clean system. Add glycol chiller and nitrogen generator for nitro coffee.Complete
2024-06-03expired 2024-11-30TS-PRM-0624-00248City permit recordSign - PermanentRemove the existing manual price changer and install new LED electronic price changer as per attached drawing.Expired
2024-03-28finaledTR-UTL-0324-00658City permit recordRight-of-Way (ROW) - UtilityPRJ269113-1 Cox to pull coax cable through 330' of existing conduit for CATV Service Drop.Complete
2023-07-18finaledTC-COM-0723-01762City permit recordCommercial BuildingCoffee Wow Phase 1: equipment and mill work modifications to existing coffee bar and lid bar.Complete
Show 5 older records
Permit history for this parcel — remaining 5 records
DateRecordWhatStatusValue
2020-08-10finaledT20RW04545City permit recordROWStarting on the S/E corner of E. River Rd and N. Craycroft Rd at Cox Existing Vault overpull .48 ct fiber through existing conduit going South for 655' Continue South trench / bore installing 2 -2" conduits and .48 ct fiber for 235' place a 3x3x3 pothole, Continue trench/bore West 106' placing 3x3x3 pothole, trench bore 15' to out of row.Final
2020-07-30finaledT20RW04376City permit recordROWINSTALLATION OF 2" PVC CONDUDIT FOR FIRST DIGITAL TELECOM - @ 570' IN DIRT - TRENCH/BORE ASPHALT DRIVEWAY 46 LF. 1. Add "Bike Lane Closed Ahead" sign on North bound Craycroft, just south of the River Rd intersection and also another West bound on River Rd, just east of the intersection. 2. Ingress/ Egress for business and residential access shall be maintained. 3. A Safe and ADA compliant route for pedestrians access needs to be available from River Rd to Craycroft Rd. 4. Restoration of landscape areas shall be restored to the same as or better than prior work. 5. Contractor is responsible for trench compaction in the right of way. ADDRESS ON APPLICATION: 5605 E River RdFinal
2020-05-26finaledT20RW02971City permit recordRight-of-Way (ROW)JOC for Fencing Installation & Repair, Contract Number: 171759-02REMOVAL OF OLD GUARDRAIL AND RE; Work Order: 2022775Complete
2020-04-30finaledT20RW02445City permit recordROWINSTALLATION OF 2" PVC CONDUDIT FOR FIRST DIGITAL TELECOM - @ 570' IN DIRT - TRENCH/BORE ASPHALT DRIVEWAY 46 LF. 1. Add "Bike Lane Closed Ahead" sign on North bound Craycroft, just south of the River Rd intersection and also another West bound on River Rd, just east of the intersection. 2. Ingress/ Egress for business and residential access shall be maintained. 3. A Safe and ADA compliant route for pedestrians access needs to be available from River Rd to Craycroft Rd. 4. Restoration of landscape areas shall be restored to the same as or better than prior work. 5. Contractor is responsible for trench compaction in the right of way. ADDRESS ON APPLICATION: 5605 E River RdFinal
2018-11-01finaledT18RW04911City permit recordROWFROM THE COX PEDESTAL ON THE SE CORNER OF RIVER RD/CRAYCROFT RD, BEGIN 275' METRO TRENCH/BORE HEADING EAST, PLACING 4-2" CONDUITS. CONTINUE SOUTH 25' BORE/TRENCH TO OUT OF ROWFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 109224440 — 13 permits on file from 2018 to 2026 (4 row, 2 commercial building, 1 solar pv, 1 fire construction) — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.