Electrical permit history — 2502 E River Rd

2502 E River Rd, Tucson — built 2007, with 17 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

2502 E River Rd

Built 2007 — 2000s commercial stock · last permitted panel/service work 2007 (finaled)

Parcel
108240800
Built
2007 (county record)
Jurisdiction
Tucson
Zoning
O-3
Assessor use
Office Condominium 1 Story
Parcel size
0.14 acres
Building area
4,240 sq ft (assessor record)
Sewer
Connection on file (2006) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Service on record
City records show the 2007 permit was finalized; the permit description states “Add 48' new 4" fire service underground piping”.

See the property

County aerial photograph centered on 2502 E River Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionCurrentLast permitted 2007 (19 years ago). City inspection record: last recorded inspection 2007-08-24; no approved final is shown. Contractor of record: FIRST SERVICE FIRE PROTECTION *C. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T07BU01664 — Add 48' new 4" fire service underground piping
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2007 spklr permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyGetting onLast permitted 2007 (19 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T07BU02230 — Add 50 fire sprinklers
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Routine

    Office and medical tenant improvements are usually limited by available panel spaces and branch circuit capacity, not by the service itself.

Recorded sales (2)

Recorded transfers from the Pima County Assessor — 2 of 2
DatePriceType
2007-05-14$620,000Warranty Deed
2005-06-02$305,000Special Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2024-11-20 (TS-PRM-1124-00509) — x2 non illuminated wall sign.

Permit history (17)

Permit history for this parcel — 8 of 17 records
DateRecordWhatStatusValue
2024-11-20expired 2025-07-13TS-PRM-1124-00509City permit recordFence / wallx2 non illuminated wall signIssued
2024-10-22finaledTR-UTL-1024-02027City permit recordRight-of-Way (ROW) - UtilityP.266321 - BORE 271', DIG 1 PIT , PLACE 1 NEW HH, & ACCESS MH 19977 FOR SPLICINGComplete
2019-04-09finaledT19OT00325City permit recordFence / wall1-NON ILLUM WALL SIGNFinal
2017-11-08expired 2018-01-13T17RW05000City permit recordROWSTART POINT SOUTH SIDE OF EAST RIVER RD AND WEST OF N HACIENDA DEL SOL RD, FROM TEP POLE, RISER DOWN PULL THROUGH EXISTING 25' TO OUT OF ROWExpired
2017-05-31finaledT17OT00563City permit recordSIGN2- NON ILLUM WAL SIGNSFinal
2009-05-26finaledT09OT01043City permit recordSIGN16707Final
2009-01-22C10-02-17City permit recordLUCAPHSTClosed
2008-07-18expired 2009-01-19T08OT01726City permit recordSIGN15329Withdrwn
Show 9 older records
Permit history for this parcel — remaining 9 records
DateRecordWhatStatusValue
2008-04-03T08EX00297City permit recordEXCAVVoid
2008-04-03finaledT08OT00786City permit recordSIGN14731Final
2007-10-22finaledT07BU02230City permit recordSPKLRAdd 50 fire sprinklersFinal
2007-10-08finaledT07BU02130City permit recordSPKLRAdd 46 fire sprinklersFinal
2007-09-14finaledT07CM03748City permit recordCOMBOTI: OFFICEC of o
2007-08-06finaledT07BU01664City permit recordSPKLRAdd 48' new 4" fire service underground pipingFinal
2007-06-19finaledT07CM02540City permit recordCOMBONEW SHELL BLDG FOR OFFICES R1-plumbing revision & roof framing revision.Final
2004-07-09expired 2005-01-17T04CM03163City permit recordCOMBOSALES TRAILERWithdrwn
2003-09-02T03CM04297City permit recordCOMBONEW OFFICE BLDG:Withdrwn

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (1)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 1 of 1 records
DateRecordWhatStatus
2009-08-20finaledT09FR02723Code enforcement caseFireComplete

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 108240800 — 17 permits on file from 2003 to 2024 (4 sign, 4 combo, 3 spklr, 2 fence / wall) and 1 code enforcement case — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.