Electrical permit history — 4545 N Via Entrada

4545 N Via Entrada, Tucson — built 1983, with 128 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Multifamily property

4545 N Via Entrada

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1983 — 1980s multifamily stock · last permitted panel/service work 2022 (finaled)

Is it time to upgrade?

  • Electrical service & distributionFinaled permit foundLast permitted 2022 (4 years ago). City inspection record: COT - LCEL - Electrical Final approved 2023-05-09. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T22CM08011 — Install new 200A 3-Phase service from utility transformer. Install new underground conduit and wire
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2024 pool / spa permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    A finaled 2022 panel/service permit is on record for this parcel, which makes it unlikely the original 100–150 A equipment is still in place. That is a permit record, not an inspection — verify the installed rating and the panel brand on site before sizing anything new. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    A pool or spa was permitted in 2024. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Worth confirming

    There is an electrical reconnect permit from 2005. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

Solar and energy potential

Roof footprint
≈ 121,432 sq ft (county building-footprint layer, 42 structures)
Usable for solar, planning estimate
≈ 85,000 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 940 kW — roughly 2,350 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 1,550,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$124,000–$202,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “El Con Mall - Reid Park Area”, is about 4.5 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
108213300
Year constructed
1983 (county record)
Permitting authority
Tucson
Zoning
R-3
Property type
Apartments 100+ Units 3 Or More Story
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X (shaded) — 0.2% annual-chance flood hazard (FEMA)
Service on record
City records show the 2022 permit was finalized; the permit description states “Install new 200A 3-Phase service from utility transformer. Install new underground conduit and wire”.

The most recent permitted work on this parcel was in 2025. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2025. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 128 building permits for this parcel dated between 2002 and 2025. By category the work is commercial building (27), pool / spa (3) and trade permit. 24 of them carry a final inspection; the other 104 were issued, expired or are still open, which is not the same as work completed. There are 11 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 108213300. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All multifamily property · Commercial property in 85718 · Commercial & industrial reports · Homes in 85718 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The flood zone shown is FEMA’s National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

Complete permit record (139 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2025CE-VIO0725-03204Code enforcement caseClosed - unfounded
2025TC-COM-0325-00608Commercial BuildingComplete
2025TC-RES-0325-01508Residential Building - One or Two FamilyVoid
2024TC-COM-0124-00024Commercial BuildingComplete
2023TC-COM-0923-02127Commercial BuildingComplete
2023TC-COM-0823-02114Commercial BuildingWithdrawn
2023TD-DEV-0623-00268Development PackageIssued
2023TZ-CMP-0523-00109Zoning Verification LetterComplete
2022T22CM08011Commercial BuildingComplete
2022T22CM03279Commercial BuildingIssued
2022T22CM03280Commercial BuildingIssued
2022T22CM03282Commercial BuildingIssued
2022T22CM03283Commercial BuildingIssued
2022T22CM03284Commercial BuildingIssued
2022T22CM03285Commercial BuildingIssued
2022T22CM03286Commercial BuildingIssued
2022T22CM03287Commercial BuildingIssued
2022T22CM03288Commercial BuildingIssued
2022T22CM03289Commercial BuildingIssued
2022T22CM03290Commercial BuildingIssued
2022T22CM03291Commercial BuildingIssued
2022T22CM03292Commercial BuildingIssued
2022T22CM03293Commercial BuildingIssued
2022T22CM03294Commercial BuildingIssued
2022T22CM03295Commercial BuildingIssued
2022T22CM03296Commercial BuildingIssued
2022T22CM00822Commercial BuildingIssued
2021T21OT00524Sign - PermanentExpired
2020T20DV02330Code enforcement caseComplian
2019T19CM04905Commercial BuildingExpired
2019T19CM04902COMBOExpired
2019T19CM04904COMBOExpired
2019T19CM04687COMBOExpired
2019T19CM04689COMBOExpired
2019T19CM04034COMBOExpired
2019T19CM04035COMBOExpired
2019T19CM04036COMBOExpired
2019T19CM04037COMBOExpired
2019T19CM04039COMBOExpired
2019T19CM04040COMBOExpired
2019T19CM04041COMBOExpired
2019T19CM04042COMBOExpired
2019T19CM03743COMBOExpired
2019T19CM03746COMBOExpired
2019T19CM03747COMBOExpired
2019T19CM03748COMBOExpired
2019T19CM03666COMBOExpired
2019T19CM03668COMBOExpired
2019T19CM03670COMBOExpired
2019T19CM03673COMBOExpired
2019T19CM03674COMBOExpired
2019T19CM03353COMBOExpired
2019T19CM03354COMBOExpired
2019T19CM03199COMBOExpired
2019T19CM03136COMBOExpired
2019T19CM03137COMBOExpired
2019T19CM03129COMBOExpired
2019T19CM02739COMBOExpired
2019T19CM02740COMBOExpired
2019T19CM02741COMBOExpired
2019T19CM02742COMBOExpired
2019T19CM02484COMBOExpired
2019T19CM02485COMBOExpired
2019T19CM02375COMBOExpired
2019T19CM02376COMBOExpired
2019T19CM02120COMBOFinal
2019T19CM02122COMBOExpired
2019T19CM02123COMBOExpired
2019T19CM01940COMBOFinal
2019T19CM01942COMBOExpired
2019T19CM01944COMBOExpired
2019T19CM01945COMBOExpired
2019T19CM01802COMBOExpired
2019T19CM01670COMBOExpired
2019T19CM01671COMBOExpired
2019T19CM01672COMBOExpired
2019T19CM01675COMBOExpired
2019T19CM01676COMBOFinal
2019T19CM01678COMBOExpired
2019T19CM01680COMBOExpired
2019T19CM01681COMBOExpired
2019T19CM01682COMBOExpired
2019T19CM01380Commercial BuildingExpired
2019T19CM01381Commercial BuildingExpired
2019T19CM01384Commercial BuildingExpired
2019T19CM01382COMBOExpired
2019T19CM01383COMBOClosed
2019T19CM00941Commercial BuildingExpired
2019T19CM00935COMBOExpired
2019T19CM00937COMBOExpired
2019T19CM00939COMBOExpired
2019T19CM00940COMBOExpired
2019T19CM00942COMBOExpired
2019T19CM00182Commercial BuildingCanceled
2019T19CM00183COMBOExpired
2019T19CM00185COMBOExpired
2019T19CM00186COMBOExpired
2019T19CM00189COMBOExpired
2019T19CM00190COMBOExpired
2019T19CM00052COMBOExpired
2019T19CM00053COMBOExpired
2018T18CM10073COMBOExpired
2018T18CM10074COMBOExpired
2018T18CM10075COMBOExpired
2018T18CM10076COMBOExpired
2018T18CM09928COMBOL of c
2018T18CM09825COMBOFinal
2018T18CM09827COMBOExpired
2018T18CM09828COMBOExpired
2018T18CM09830COMBOFinal
2018T18CM09643COMBOExpired
2018T18CM09575COMBOExpired
2018T18CM09577COMBOFinal
2018T18CM09578COMBOFinal
2018T18CM09579COMBOExpired
2018T18CM09049COMBOFinal
2018T18CM09050COMBOExpired
2018T18CM09051COMBOFinal
2018T18CM09052COMBOFinal
2018T18CM09053COMBOExpired
2018T18CM08030COMBOFinal
2018T18CM07858Commercial BuildingExpired
2018T18DV00297FireComplian
2017T17CM00769COMBOFinal
2015T15DV06173Code enforcement caseComplian
2015T15CM00294COMBOFinal
2011T11DV01013 (no public file link)SIGN VIOLATIONCOMPLIAN
2010T10CM01390COMBOFinal
2010T10CM00719COMBOFinal
2010T10DV01434 (no public file link)RESIDENTIAL FIREREFERRED
2010T10DV01034FireComplian
2009T09DV05053Code enforcement caseComplian
2005T05EL00502ELECTFinal
2002T02OT01988SIGNFinal
2002T02VL02279SignComplian
2002T02VL01697Code enforcement caseComplian
2002T02AN00273ADDRNEWIssued
2002T02CM01633COMBOC of o
2000T00VL00340Code enforcement caseClosed

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 108213300 — 128 permits on file from 2002 to 2025 (91 combo, 27 commercial building, 3 pool / spa, 1 trade permit) and 11 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-22; the permit record is refreshed on a rolling cycle (at least every 45 days), and the assessor’s building file when the county publishes a new roll. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.