Electrical permit history — 4601 N Via Entrada
4601 N Via Entrada, Tucson — built 1985, with 44 permits on record. Review electrical, HVAC and remodel history with links to official records.
Multifamily property
4601 N Via Entrada
Built 1985 — 1980s multifamily stock · last permitted panel/service work 2025 (finaled)
Permanent link: Electrical permit history for 4601 N Via Entrada (aztucsonelectricalsolutions.com/property/10821323a/4601-n-via-entrada-tucson-az-85718) · Public records last checked 2026-08-16
- Parcel
- 10821323A
- Built
- 1985 (county record)
- Jurisdiction
- Tucson
- Zoning
- R-3
- Assessor use
- Apartments 100+ Units 3 Or More Story
- Parcel size
- 7.70 acres
- Building area
- 158,202 sq ft (assessor record)
- Sewer
- No connection on file (sewer or septic status not confirmed by the record — verify on site)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
- Service on record
- City records show the 2025 permit was finalized; the permit description states “Replace an 8 Meter Stack Existing 2 gang meter stack Total number of meters is 8- Like for Like. The meter for 1014 Bussing is burnt out, and requiring the entire stack to be replaced.”.
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionCurrentLast permitted 2025 (1 year ago). City inspection record: COT - LCEL - Electrical Final approved 2025-02-26. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. TC-COM-0125-00124 — Replace an 8 Meter Stack Existing 2 gang meter stack Total number of meters is 8- Like for Like. The meter for 1014 Bussing is burnt out, and requiring the entire stack to be replaced.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2018 combo permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
Recorded sales (1)
| Date | Price | Type |
|---|---|---|
| 2006-12-27 | $17,451,000 | Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2025-01-20 (TC-COM-0125-00124) — Replace an 8 Meter Stack Existing 2 gang meter stack Total number of meters is 8- Like for Like. The meter for 1014 Bussing is burnt out, and requiring the entire stack to be replaced..
Permit history (44)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2025-01-20finaled | TC-COM-0125-00124City permit record | Commercial BuildingReplace an 8 Meter Stack Existing 2 gang meter stack Total number of meters is 8- Like for Like. The meter for 1014 Bussing is burnt out, and requiring the entire stack to be replaced. | Complete | |
| 2024-04-04expired 2024-10-20 | TC-COM-0424-00602City permit record | Commercial BuildingInstallation of a 30 Amp Single Phase Receptacle for new ice machine. | Issued | |
| 2023-05-05finaled | TZ-CMP-0523-00109City permit record | Zoning Verification LetterEnvii Apartments 4500, 4504, 4505, 4508, 4509, 4512, 4513, 4520, 4521, 4524, 4528, 4529, 4532, 4533, 4536, 4537, 4540, 4543, 4545, 4601 North Via Entrada (Parcels: 108-21-3300, 108-21-323A) Zoning Letter Request | Complete | |
| 2022-04-26 | T22CM03120City permit record | COMBOAdding laundry facilities within existing apartment units. | Withdrwn | |
| 2022-04-26 | T22CM03122City permit record | COMBOAdding laundry facilities within existing apartment units. | Withdrwn | |
| 2022-04-26 | T22CM03123City permit record | COMBOAdding laundry facilities within existing apartment units. | Withdrwn | |
| 2022-04-26 | T22CM03124City permit record | COMBOAdding laundry facilities within existing apartment units. | Withdrwn | |
| 2022-04-26 | T22CM03125City permit record | COMBOAdding laundry facilities within existing apartment units. | Withdrwn |
Show 36 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2022-04-26 | T22CM03126City permit record | COMBOAdding laundry facilities within existing apartment units. | Withdrwn | |
| 2022-04-26 | T22CM03127City permit record | COMBOAdding laundry facilities within existing apartment units. | Withdrwn | |
| 2022-04-26 | T22CM03128City permit record | COMBOAdding laundry facilities within existing apartment units. | Withdrwn | |
| 2022-04-26 | T22CM03129City permit record | COMBOAdding laundry facilities within existing apartment units. | Withdrwn | |
| 2022-04-26 | T22CM03130City permit record | COMBOAdding laundry facilities within existing apartment units. | Withdrwn | |
| 2022-04-26 | T22CM03131City permit record | COMBOAdding laundry facilities within existing apartment units. | Withdrwn | |
| 2019-01-16expired 2020-02-08 | T19CM00313City permit record | Commercial BuildingNEW GAS LINE | Expired | |
| 2018-12-13finaled | T18CM09733City permit record | COMBOINTERIOR REMODEL | L of c | |
| 2018-12-13expired 2019-10-06 | T18CM09734City permit record | COMBOINTERIOR REMODEL | Expired | |
| 2017-11-01finaled | T17CM08176City permit record | COMBOREPL MTR SOCKET WITH BUSS BARS AND INSULATOR AND MAIN BREAKER | Final | |
| 2016-01-13finaled | T16CM00320City permit record | COMBOREPLACE MAIN 100 AMP BREAKER AND BUSSING APARTMENT UNITS #2020 AND #1008 | Final | |
| 2015-01-15finaled | T15CM00293City permit record | COMBOREPLACE BAD BREAKERS AT METER BASE | Final | |
| 2015-01-15finaled | T15CM00295City permit record | COMBOREPLACE BAD BREAKERS AT METER BASE | Final | |
| 2014-10-13finaled | T14CM06843City permit record | COMBOREPLACE (4) BREAKERS THAT FEED APARTMENTS | Final | |
| 2014-07-14finaled | T14CM04388City permit record | COMBOREPLACE BAD BREAKER AND METER BASE | Final | |
| 2014-07-14finaled | T14CM04389City permit record | COMBOREPLACE BAD BREAKER AND METER BASE | Final | |
| 2014-07-14finaled | T14CM04390City permit record | COMBOREPLACE BAD BREAKER AND METER BASE | Final | |
| 2014-04-07finaled | T14CM01955City permit record | COMBOCHANGE OUT MAIN BREAKER FOR FOUR APTS BUILDING #6 | Final | |
| 2014-02-04finaled | T14CM00674City permit record | COMBOCHANGING MAIN BREAKERS | Final | |
| 2013-07-11finaled | T13CM04207City permit record | COMBOREPLACE 8 PACK ELECTRIC PANEL BOX | Final | |
| 2013-07-11finaled | T13CM04208City permit record | COMBOREPLACE 8 PACK ELECTRIC PANEL BOX | Final | |
| 2013-05-10 | T13CM02839City permit record | COMBOREPLACEMENT OF 100 AMP BREAKER | Void | |
| 2013-05-09finaled | T13CM02819City permit record | COMBOREPLACE 100 AMP BREAKER- APARTMENTS | Final | |
| 2013-01-10finaled | T13CM00170City permit record | COMBOREPLACE MAIN BREAKER | Final | |
| 2012-10-15finaled | T12CM06450City permit record | COMBOREPLACE MAIN BREAKER AND BUSSING (APA) | Final | |
| 2012-10-03finaled | T12CM06173City permit record | COMBOREPLACE BREAKERS AND BUSSING (APA) | Final | |
| 2012-08-13finaled | T12CM04991City permit record | COMBOREPLACE BREAKERS IN TWO UNITS UP TO 200 AMP (APA) | Final | |
| 2012-05-18finaled | T12CM02835City permit record | COMBOREPLACE 100 AMP MAIN BREAKERS & BUSS BARS - (APA) | Final | |
| 2012-01-11expired 2012-07-17 | T12EL00090City permit record | ELECTREPLACE: MAIN BREAKER AT METER SECTION: COMM(APA) | Expired | |
| 2011-12-21finaled | T11EL03278City permit record | ELECTREPAIR: 100 AMP MAIN BREAKER - RES (APA) R1; BUSS BARS FOR #2004 | Final | |
| 2011-12-19finaled | T11EL03256City permit record | ELECTREPLACE: MAIN BREAKER AT METER SECTION: COMM | Final | |
| 2011-12-15expired 2012-06-13 | T11EL03237City permit record | ELECTREPLACE: MAIN BREAKER AT METER SECTION: COMM | Withdrwn | |
| 2002-12-13finaled | T02EL02419City permit record | ELECTELECTRIC:INSTALL 100 AMP SERVICE | Final | |
| 2002-03-29finaled | T02CM01646City permit record | COMBOTI:BUSINESS CENTER | C of o | |
| 2002-03-29finaled | T02CM01647City permit record | COMBOTI:CLUBHOUSE | C of o | |
| 2002-03-28 | T02AN00271City permit record | ADDRNEW | Issued |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (2)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2012-01-11 | T12DV00196Code enforcement case | Code enforcement case | Noverify |
| 2004-12-15 | T04DV00977Code enforcement case | Code enforcement case | Void |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Send: the permanent link and the summary above, once. Watch: one email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list either way.
How this report was built
This is a reading of public records for parcel 10821323A — 44 permits on file from 2002 to 2025 (34 combo, 5 elect, 3 commercial building, 1 zoning verification letter) and 2 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.