Electrical permit history — 4490 N 1st Av

4490 N 1st Av, Tucson — built 1993, with 28 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

4490 N 1st Av

Built 1993 — 1990s commercial stock · HVAC 2012 (finaled)

Parcel
108192180
Built
1993 (county record)
Jurisdiction
Tucson
Zoning
C-3
Assessor use
Health & Fitness Club Fraternal/Sorority
Parcel size
0.41 acres
Building area
5,017 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X (shaded) — 0.2% annual-chance flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 4490 N 1st Av, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalGetting onLast permitted 2012 (14 years ago). City inspection record: MECHANICAL - FINAL approved 2012-07-05. Contractor of record: AIR O SMITH HEATING AND COOLING. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. T12CM03887 — CHANGE OUT 1.5 TON PACKAGE HEAT PUMP - LIKE FOR LIKE
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Most recent permit on record for this parcel: 2025-05-05 (TR-ROW-0525-00599) — We will be performing twenty-one (21) geotechnical borings within the roadway of N 1st Ave from approximately 500ft north of the intersection of E River Rd and N 1st Ave to approximately 400ft north of the intersection of N 1st Ave and Grant Rd. Asphalt coring will be conducted prior to drilling of soil borings. Cores will be obtained using an electric coring rig and will be approximately 10 inches in diameter. The soil borings will be advanced through the 10 inch asphalt core hole with 7 or 8 inch hollow stem auger to depths of approximately 5 to 150 feet below the ground surface (135 to 150ft borings will be performed near the 1st Avenue Bridge crossing the Rillito River. The borings will be backfilled with auger cuttings mixed with concrete (with concrete comprising between 20 to 50% of the soil-cement backfill). The exposed asphalt concrete at each boring location will be cleaned, wire-brushed, and patched with QPR brand asphalt cold path. (We understand the restoration of boring locations in the existing roadway as described above will be acceptable by the City of Tucson.) If groundwater is encountered during drilling, the boring will be backfilled with cement grout to the state minimum of the upper 20 feet, unless otherwise within the threshold distance of a WQARF, CERCLA, VRP, LUST, or DOD site, the boring(s) will be backfilled with cement grout to the full depth of the boring. See site plan for details on locations of planned boreholes and traffic control plans for anticipated one-lane closures along N 1st Ave. We do not anticipate performing any work within signalized intersections. Requesting no restrictions on work times. 135 to 150ft bridge borings will be performed as night work. Work performed for HDR Engineering for the City of Tucson, Contract No. 230193-01. 05/22/2025 **Withdrawn as of 05/21/2025 CONTINUATION OF TR-ROW-0325-00338*** NO LONGER NEEDED.

Permit history (28)

Permit history for this parcel — 8 of 28 records
DateRecordWhatStatusValue
2025-05-05TR-ROW-0525-00599City permit recordRight-of-Way (ROW)We will be performing twenty-one (21) geotechnical borings within the roadway of N 1st Ave from approximately 500ft north of the intersection of E River Rd and N 1st Ave to approximately 400ft north of the intersection of N 1st Ave and Grant Rd. Asphalt coring will be conducted prior to drilling of soil borings. Cores will be obtained using an electric coring rig and will be approximately 10 inches in diameter. The soil borings will be advanced through the 10 inch asphalt core hole with 7 or 8 inch hollow stem auger to depths of approximately 5 to 150 feet below the ground surface (135 to 150ft borings will be performed near the 1st Avenue Bridge crossing the Rillito River. The borings will be backfilled with auger cuttings mixed with concrete (with concrete comprising between 20 to 50% of the soil-cement backfill). The exposed asphalt concrete at each boring location will be cleaned, wire-brushed, and patched with QPR brand asphalt cold path. (We understand the restoration of boring locations in the existing roadway as described above will be acceptable by the City of Tucson.) If groundwater is encountered during drilling, the boring will be backfilled with cement grout to the state minimum of the upper 20 feet, unless otherwise within the threshold distance of a WQARF, CERCLA, VRP, LUST, or DOD site, the boring(s) will be backfilled with cement grout to the full depth of the boring. See site plan for details on locations of planned boreholes and traffic control plans for anticipated one-lane closures along N 1st Ave. We do not anticipate performing any work within signalized intersections. Requesting no restrictions on work times. 135 to 150ft bridge borings will be performed as night work. Work performed for HDR Engineering for the City of Tucson, Contract No. 230193-01. 05/22/2025 **Withdrawn as of 05/21/2025 CONTINUATION OF TR-ROW-0325-00338*** NO LONGER NEEDEDWithdrawn
2022-12-02expired 2023-04-23TR-UTL-1222-00359City permit recordRight-of-Way (ROW) - UtilityPRJ234387-1 From TEP pole on the East side of 1st Ave Pull .288 ct. fiber up pole begin 528' aerial Overlash North, Tie inIn review
2021-04-16DP21-0101City permit recordAddition / alterationSITE/GRADING - Prestige Fitness, 1,683 SF addition, gymnasium.Fees due
2020-09-10finaledT20RW04980City permit recordROWRiser down pole in NW corner of 4490 N 1st Ave, head N and begin 10' trench/bore to Cox vault. From Cox Vault, head SE and continue 77' trench/bore placing 1-2" conduit and 288ct fiber in to out of ROW.Final
2019-09-19finaledT19RW05407City permit recordROWREPAIR BROKEN WTER VALVE 6LF E/SD OF LOT IN DIRT AREA. EMERGENCY CREW IS ON SITE ADDRESS ON APP IS 4485 N 1ST AVE EMERGENCY AFTER THE FACTFinal
2017-09-05T17CM06751City permit recordAddition / alterationADDITION AND REMODEL GYMExpired
2017-07-07expired 2018-03-17DP17-0165City permit recordDevelopment PackageSITE - PRESTIGE FITNESS EXPANSIONOriginal Approval 09.15.17 (7 pages)Issued
2012-08-13finaledT12CM04990City permit recordCOMBOPACKAGE HEAT PUMP 5 TONFinal
Show 20 older records
Permit history for this parcel — remaining 20 records
DateRecordWhatStatusValue
2012-06-29finaledT12CM03887City permit recordCOMBOCHANGE OUT 1.5 TON PACKAGE HEAT PUMP - LIKE FOR LIKEFinal
2010-11-22D10-0041City permit recordDevelopment PackagePRESTIGE FITNESSApproved
2010-10-18finaledT10CM02891City permit recordCOMBOENCLOSE:PORCH TO FITNESS ROOMFinal
2010-09-27expired 2010-11-26T10EX00478City permit recordEXCAVLANDSCAPE & IRRIGATIONClosed
2010-08-31finaledT10ME00563City permit recordMECHMECHANICAL:REPLACT 5 TON HEAT PUMPFinal
2010-07-27finaledT10ME00467City permit recordMECHMECHANICAL:REPLACE 5 TON HEAT PUMPFinal
2009-06-17finaledT09OT01239City permit recordSIGN16827Final
2009-06-08finaledT09CM01460City permit recordCOMBOTI and C of O: FITNESS CENTERC of o
2009-05-28finaledT09OT01072City permit recordSIGN16727Final
2006-11-20T06PL02147City permit recordPLUMBREPL BACKFLOW ASSEMBLY LIKE FOR LIKEWithdrwn
2005-07-25finaledT05OT01824City permit recordSIGNSIGN : 9401 CHUY'S MESQUITE BROILERFinal
2005-01-13finaledT05BU00092City permit recordBUILDINSTALL:KITCHEN SUPPRESSION SYSTEMFinal
2004-11-30finaledT04OT02338City permit recordSIGNSIGN:ELECTRIC:8127 CHUY'S MESQUITE BROILERFinal
2004-10-27finaledT04CM04751City permit recordCOMBOTI:RESTAURANTC of o
2004-10-18T04CM04640City permit recordCOMBOTI:CHUYS MESQUITE BROILERWithdrwn
2003-07-25finaledT03CM03708City permit recordCOMBOTI:RETAILC of o
2003-07-25finaledT03OT01357City permit recordSIGNSIGN:#5845Final
2003-07-25finaledT03OT01359City permit recordSIGNSIGN:# 5844Final
2003-07-14T03OT01253City permit recordC-OF-OC OF O:LOW CARB MALL, INC.Withdrwn
2001-07-26finaledT01EL01965City permit recordELECTSIGN:ELECTRIC:2801Final

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (5)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 5 of 5 records
DateRecordWhatStatus
2014-01-10T14DV00193Code enforcement caseSignComplian
2011-09-20T11DV07501Code enforcement caseSignComplian
2010-09-30finaledT10FR01992Code enforcement caseFireComplete
2007-04-11finaledT07FR00698Code enforcement caseFireComplete
2005-02-02finaledT05FR00162Code enforcement caseCode enforcement caseComplete

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 108192180 — 28 permits on file from 2001 to 2025 (7 combo, 6 sign, 2 addition / alteration, 2 row) and 5 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.