Electrical permit history — 5 E Kelso St
5 E Kelso St, Tucson — built 1994, with 45 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
5 E Kelso St
Built 1994 — 1990s commercial stock · 45 permits on record; no permitted panel/service or HVAC work among them
Permanent link: Electrical permit history for 5 E Kelso St (aztucsonelectricalsolutions.com/property/10713032a/5-e-kelso-st-tucson-az-85705) · Public records last checked 2026-08-17
- Parcel
- 10713032A
- Built
- 1994 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-2
- Assessor use
- Store Front Commercial Bldg
- Parcel size
- 1.66 acres
- Building area
- 25,000 sq ft (assessor record)
- Sewer
- Connection on file (1983, 1984) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyGetting onA newer 2023 permit for the same system is recorded as “Expired” — The permit expired without a confirmed final status. The permit description states “Upgrade cellular dialer to wireless monitoring”. Last permitted 2009 (17 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T09BU01808 — Install 71 fire sprinklers
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check
Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
Recorded sales (2)
| Date | Price | Type |
|---|---|---|
| 2005-10-13 | $1,280,000 | Warranty Deed |
| 2004-07-07 | $940,000 | Special Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2026-04-02 (TF-FOP-0426-00445) — LP-GAS.
Permit history (45)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2026-04-02 | TF-FOP-0426-00445City permit record | Fire OperationalLP-GAS | Fees paid | |
| 2026-02-26finaled | TF-FOP-0226-00293City permit record | Fire Operational | Complete | |
| 2026-02-26 | TF-FOP-0226-00295City permit record | Fire OperationalVOID -Submit a Fire General Operational - LP Gas - LP Gas Permit | Void | |
| 2026-02-06expired 2026-08-03 | TR-UTL-0226-00223City permit record | Right-of-Way (ROW) - UtilityZayo Contractor ADB Companies to install conduit/fiber via Directional Bore and open trench for an estimated 5,283 LF. Zayo Handholes to be installed every 2,000 LF for future access and maintenance. 04/20/2026 - Request for 90 Day Renewal as of 05/05/2026 | Inspections | |
| 2025-10-22finaled | TR-UTL-1025-01833City permit record | Right-of-Way (ROW) - Utilitywo#3144847 2700 n stone ave 13-13-36 sw leaking main at the south side of the lot on e kelso st in asphalt 5lf/ar | Complete | |
| 2025-01-17finaled | TC-COM-0125-00110City permit record | Commercial BuildingRun new 2” gas service from capped off area of existing gas service on roof Supply and install 85 ft of 2” 1 1/2” and 1” gas service to 2 existing gas pack units on west end of building Gas line will be placed on roof jacks placed every 6ft to properly secure pipe to roof Will supply new isolation valves at both gas packs where gas is to be connected As is will perform gas pressure test to new gas line run before introducing to gas service | Complete | |
| 2024-12-10finaled | TF-FOP-1224-01485City permit record | Fire OperationalAnnual Inspection | Complete | |
| 2023-11-28finaled | TF-FOP-1123-01801City permit record | Fire OperationalState License Facility Annual Inspection | Complete |
Show 37 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2023-11-28finaled | TF-FOP-1123-01803City permit record | Fire OperationalLP-Gas | Complete | |
| 2023-09-27expired 2024-04-25 | TF-FCP-0923-01152City permit record | Fire ConstructionUpgrade cellular dialer to wireless monitoring | Expired | |
| 2022-12-30finaled | TF-FOP-1222-00284City permit record | Fire OperationalOccupancy Load - 569 | Complete | |
| 2021-11-10finaled | T21FO00790City permit record | FIREOPEROUTPATIENT | Final | |
| 2021-10-06finaled | T21RW04563City permit record | ROWTUC KASHMIR SC4 SMALL SITE MAINTENANCE | Final | |
| 2021-10-01finaled | T21RW04503City permit record | ROWKEELING SLOW STREETS (SLOW STREETS PROGRAM) PLACEMENT OF TEMPORARY BARRICADES TO SLOW TRAFFIC AND MITIGATE CUT-THROUGH TRAFFIC ALONG THE RESIDENTIAL STREETS OF E. KELSO STREET FROM STONE AV TO N LOS ALTOS AV, THEN SOUTHBOUND ON LOS ALTOS AV TO E JACINTO ST AND THEN EASTBOUND ON E JACINTO STREET TO 1ST AVENUE. | Final | |
| 2021-02-09expired 2022-02-24 | T21FC00102City permit record | Fire ConstructionFire Alarm & Detection Systems - Add of (1) NAC Power Supply (5) Pull Stations and (2) Horn Strobes. to Existing Vista 32FB Panel - (1) Pull & (1) Horn/Strobe Already Exists On System; Fire Alarm Systems - Devices Modified: 10 | Expired | |
| 2021-01-04finaled | T21FO00006City permit record | FIREOPERBEACON GROUP | Final | |
| 2020-11-09finaled | T20FO00593City permit record | FIREOPERBEACON GROUP | Final | |
| 2020-07-06finaled | T20RW03783City permit record | ROWN.728716 - JOB WILL REQUIRE 2655' OF AERIAL FIBER/DUCT PLACEMENT, 4' OF TRENCHING, PLACEMENT OF NEW 3048 HH #32365. | Final | |
| 2020-07-06finaled | T20RW03786City permit record | ROWN.728716 - JOB WILL REQUIRE 171' OF AERIAL FIBER/DUCT PLACEMENT, 4' OF TRENCHING, 80' OF TRENCHING, PLACEMENT OF NEW RISER, PLACEMENT OF NEW 3048 HH #34145, AND DIG (1) 4'X4' DIG PIT. PLACE BUSINESS ACCESS SIGNS AS NEEDED | Final | |
| 2019-11-15finaled | T19RW07054City permit record | ROWCUT CURB ON KELSO STREET. CONSTRUCTION ENTRANCE AND OR EXIT DRIVEWAY 30' WIDE TO ABOUT 12' INTO SIDEWALK AND PROPERTY OR 12 FT FROM STREET TOWARDS EXISTING ASPHALT NOTES: 30' DRIVEWAY MAX. FOR BUSINESS DISTRICT GREATER SIZE WILL REQUIRE JUSTIFICATION AND A SUBMITTAL OF PLANS | Final | |
| 2018-12-06finaled | T18OT01246City permit record | Fence / wallchange of copy-2 wall signs | Final | |
| 2018-02-27finaled | T18FO00196City permit record | FIREOPERORDERS FULFILLMENT/PAINT RECYCLING | Final | |
| 2016-07-29expired 2017-08-21 | T16CM05964City permit record | COMBOTI; REPL MECHANICAL UNIT | Expired | |
| 2010-01-11finaled | T10OT00056City permit record | SIGN17759 | Final | |
| 2009-12-09finaled | T09BU01808City permit record | SPKLRInstall 71 fire sprinklers | Final | |
| 2009-11-03finaled | T09CM02915City permit record | COMBOTI:RETAIL | C of o | |
| 2009-06-16finaled | T09OT01226City permit record | SIGN16820 | Final | |
| 2008-10-01finaled | T08BU01764City permit record | BUILDINSTALL FIRE ALARM SYSTEM | Final | |
| 2008-09-12finaled | T08OT02173City permit record | SIGN15581 | Final | |
| 2008-09-09finaled | T08OT02128City permit record | SIGN15564 | Final | |
| 2008-07-23finaled | T08OT01764City permit record | SIGN15351 | Final | |
| 2008-06-30finaled | T08OT01557City permit record | SIGN15223 | Final | |
| 2008-01-24finaled | T08OT00189City permit record | SIGN14375 | Final | |
| 2008-01-08finaled | T08OT00036City permit record | SIGN14274 | Final | |
| 2007-12-04finaled | T07BU02518City permit record | GRADINGCUT 42CY FILL 0CY | Final | |
| 2007-11-16expired 2008-01-15 | T07EX01199City permit record | EXCAVCURB CUT AN NEW DRIVEWAY APRON PER COT STD. DTL. 206 | Closed | |
| 2007-10-16finaled | T07BU02189City permit record | SPKLRFIRE SPRINKLER:ADD 179 & RELOCATE 12 | Final | |
| 2006-09-11 | T06AN00945City permit record | ADDRNEW | Issued | |
| 2006-09-11finaled | T06CM04968City permit record | COMBOTI: CREATE SUITE | C of o | |
| 2006-09-11finaled | T06CM04969City permit record | COMBOTI: NEW STORE FRONT | Final | |
| 2006-09-11 | T06CM04971City permit record | COMBOTI: NEW STORE FRONT | Withdrwn | |
| 2006-09-11finaled | T06CM04972City permit record | COMBOTI: RETAIL | C of o | |
| 2006-07-12finaled | T06OT01837City permit record | SIGN11475 | Final | |
| 2006-03-17expired 2008-08-02 | T06BU00596City permit record | Fence / wallSTRUCTURAL REPAIR, ONLY: - 6 - 4'0" x OPENING WIDTH OF ROOF OPENINGS REINFORCED WITH STUCTURAL STEEL FRAME ATTACHED TO EXISTING METAL ROOF JOISTS - 1- 10' x 10' MASONRY OPENING IN EXTERIOR WALL REINFORCED WITH STRUCTURAL STEEL LINTEL AND JAMB COLUMNS | Closed | |
| 2005-12-13expired 2008-08-02 | T05CM06198City permit record | COMBOINTERIOR DEMO ONLY : (T05VL01208) - REMOVE INTERIOR PARTITIONS, FIXTURES AND EQUIPMENT OF ROLLER SKATING RINK TO FORM A SHELL BUILDING WITH TWO ROOMS : 240 FEET LONG x 100 FEET WIDE W/ 50 FEET LONG x 20 FEET WIDE 'L" - SHAPED BUILDING. - SEPARATE BUILDING PERMIT/S ARE REQUIRED FOR : REMODEL/ CHANGE OF OCCUPANCY/TENANT IMPROVEMENT/ CERTIFICATE OF OCCUPANCY. - | Closed |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (8)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2018-03-09 | T18DV01235Code enforcement case | Code enforcement case | Complian |
| 2016-12-19 | T16DV08513Code enforcement case | Graffiti | Noverify |
| 2013-08-16 | T13DV06077Code enforcement case | Fire | Complian |
| 2010-05-06 | T10DV02883Code enforcement case | Work without permit | Noverify |
| 2009-02-24 | T09FR00747Code enforcement case | Code enforcement case | Field |
| 2008-09-22 | T08FR03001Code enforcement case | Code enforcement case | Field |
| 2005-12-08 | T05VL01208Code enforcement case | Work without permit | Complian |
| 2004-05-14 | T04ZV00327Code enforcement case | Code enforcement case | Complian |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
How this report was built
This is a reading of public records for parcel 10713032A — 45 permits on file from 2005 to 2026 (9 sign, 7 fire operational, 7 combo, 5 row) and 8 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.