Electrical permit history — 3125 N Geronimo Av

3125 N Geronimo Av, Tucson — built 1950, with 39 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Manufactured home

3125 N Geronimo Av

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1950 — manufactured home · last permitted panel/service work 2020 (finaled)

Is it time to upgrade?

  • Electrical service & panelFinaled permit foundLast permitted 2020 (6 years ago). The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. T20CM06354 — UPGRADE 400 AMP
  • Heating & coolingNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 trade permit permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Cooling equipment works harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes.
  • Water heaterNot in this windowNothing in the permit records we read for this parcel that names this system. Water heaters are frequently swapped without a permit, so this line is especially weak evidence either way.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. The assessor records the roof as Composition Shingle.
  • Plumbing work on recordOn recordLast permitted 2025 (1 year ago). Plumbing permits cover everything from a full re-pipe to a few feet of sewer repair, so this is a record that work happened rather than a statement about the whole system. TC-COM-0425-00640 — Main Sewer line reroute/replacement

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    A finaled 2020 panel/service permit is on record for this parcel, which makes it unlikely the original 60–100 A equipment is still in place. That is a permit record, not an inspection — verify the installed rating and the panel brand on site before sizing anything new. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Bonding and grounding are the common finding on older units — the frame must be bonded, and the neutral and ground have to stay separated downstream of the service disconnect at the pedestal.

  • Worth confirming

    There is an electrical reconnect permit from 2004. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

  • Routine

    Adding an EV charger, a mini-split, or a casita usually means looking at the pedestal service and feeder capacity rather than the panel inside the home.

  • Routine

    A trade permit was pulled in 2025. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

What to check at the panel

Everything above is read off public records. These are the things only someone standing at the panel can settle, and they take about a minute. Check them against the rating the permit above describes rather than against the era — the permit is the better evidence, and neither one is an inspection.

  1. The rating on the main breaker at the service pedestal, not the panel inside the home — the pedestal is the service.
  2. The condition of the feeder running from the pedestal to the home, and its rating. Undersizing and corrosion show up here first.
  3. Whether the frame is bonded, and whether neutral and ground are separated downstream of the pedestal disconnect. This is the most common finding on older units.
  4. Whether the water heater, dryer and range are gas or electric — no public record carries fuel type, and it is the single biggest variable in what the service can still take.

With those in hand you can run the numbers yourself. The load calculator does the NEC 220.82 optional-method calculation — the same method a permit application uses — and shows its work.

Open the load calculator →

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
10711053A
Year constructed
1950 (assessor record)
Permitting authority
Tucson
Zoning
R-2
Living area
400 sq ft
Service on record
City records show the 2020 permit was finalized; the permit description states “UPGRADE 400 AMP” — an increase in capacity as described, not a confirmed installed rating.

The living area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2025. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2025. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 39 building permits for this parcel dated between 1999 and 2025. By category the work is trade permit (34), manufactured home (4) and right-of-way (row) permit - utility emergency. 31 of them carry a final inspection; the other 8 were issued, expired or are still open, which is not the same as work completed. There are 16 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 10711053A. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All mobile-home parks · Commercial property in 85705 · Commercial & industrial reports · Homes in 85705 · Permit data by neighborhood

Planning work at this home?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The FEMA map linked above is the National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on N GERONIMO AV hold 526 City permits on record, 86 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (55 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2026CE-VIO0826-03442GraffitiClosed - Unfounded
2025recordRight-of-Way (ROW) Permit - Utility EmergencyVoid
2025TC-COM-0425-00640Commercial Trade PermitComplete
2025TC-COM-0325-00514Commercial Trade PermitComplete
2025TC-COM-0325-00512Commercial Trade PermitComplete
2025TC-COM-0425-00641Commercial Trade PermitComplete
2025TC-COM-0425-00643Commercial Trade PermitComplete
2025TC-COM-0425-00642Commercial Trade PermitComplete
2025TC-COM-0325-00429Commercial Trade PermitComplete
2025TC-COM-0325-00527Commercial Trade PermitComplete
2025TC-COM-0325-00525Commercial Trade PermitComplete
2025TC-COM-0325-00526Commercial Trade PermitComplete
2025TC-COM-0325-00515Commercial Trade PermitComplete
2023TC-RES-1223-10159Residential Trade PermitIssued
2023CE-VIO0123-01296RefuseClosed - Unfounded
2022T22DV02276Code enforcement caseClosed - Resolved
2022T22DV00139EMERGENCYCOMPLIAN
2021T21CM04261Residential Trade PermitComplete
2021T21DV00210RESIDENTIAL STORAGENOVERIFY
2021T21DV00197MULTIPLE TYPESNOVERIFY
2021T21DV00198MULTIPLE TYPESNOVERIFY
2020T20CM06354Commercial Trade PermitComplete
2020T20CM06350Residential Trade PermitExpired
2020T20CM05235Residential Trade PermitComplete
2020T20DV05000RESIDENTIAL ZONINGNOVERIFY
2020T20EL00352Residential Trade PermitCanceled
2020T20EL00354Commercial Trade PermitCanceled
2020T20EL00353Commercial Trade PermitCanceled
2020T20DV00226RES: MINIMUM HOUSINGCOMPLIAN
2019T19PL00061Residential Trade PermitComplete
2019T19DV06591EMERGENCYCOMPLIAN
2019T19CM05670Residential Trade PermitComplete
2019T19CM05671Residential Trade PermitComplete
2019T19CM05673Residential Trade PermitComplete
2019T19CM05676Residential Trade PermitComplete
2019T19CM05682Residential Trade PermitComplete
2019T19DV06316EMERGENCYCOMPLIAN
2019T19DV06318EMERGENCYCOMPLIAN
2019T19DV06321EMERGENCYCOMPLIAN
2019T19DV06317EMERGENCYCOMPLIAN
2019T19DV06267EMERGENCYCOMPLIAN
2018T18MH00041Manufactured Home PermitComplete
2018T18MH00040Manufactured Home PermitComplete
2009T09PL01623Commercial Trade PermitComplete
2008T08DV08880RES: MINIMUM HOUSINGCOMPLIAN
2008T08PL00870Commercial Trade PermitCanceled
2008T08PL00528Commercial Trade PermitComplete
2007T07PL00550Residential Trade PermitComplete
2006T06PL00891Residential Trade PermitComplete
2006T06EL00759Residential Trade PermitComplete
2006T06EL00760Residential Trade PermitComplete
2004T04EL00062Residential Trade PermitComplete
2003T03MH00070Manufactured Home PermitComplete
2001T01MH00242Manufactured Home PermitCanceled
1999T99PL00340Residential Trade PermitComplete

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 10711053A — 39 City permits on file from 1999 to 2025 and 16 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area, roof, walls on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-09-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.