Electrical permit history — 1102 W Grant Rd

1102 W Grant Rd, Tucson — built 1957, with 82 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

1102 W Grant Rd

Built 1957 — 1950s commercial stock · last permitted panel/service work 2011 (finaled)

Parcel
10707018B
Built
1957 (county record)
Jurisdiction
Tucson
Zoning
I-1
Assessor use
Amusement Facilities
Parcel size
3.88 acres
Building area
34,766 sq ft (assessor record)
Sewer
Connection on file (1974) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Service on record
City records show the 2011 permit was finalized; the permit description states “NEW SERVICE AND SUB PANELS FOR FUTURE USE”.

See the property

County aerial photograph centered on 1102 W Grant Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionCurrentLast permitted 2011 (15 years ago). City inspection record: ELECTRIC - FINAL approved 2011-09-29. Contractor of record: DA VINCI CONSTRUCTION & DESIGN. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T11EL01544 — NEW SERVICE AND SUB PANELS FOR FUTURE USE
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentLast permitted 2015 (11 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T15BU01088 — SPRINKLER
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Recorded sales (2)

Recorded transfers from the Pima County Assessor — 2 of 2
DatePriceType
2016-06-27$1,300,000Warranty Deed
2006-04-10$750,000

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2026-04-27 (TR-ROW-0426-00506) — Investigate the dimensions of the storm drain that is south of 1102 W Grant Rd location..

Permit history (82)

Permit history for this parcel — 8 of 82 records
DateRecordWhatStatusValue
2026-04-27finaledTR-ROW-0426-00506City permit recordRight-of-Way (ROW)Investigate the dimensions of the storm drain that is south of 1102 W Grant Rd location.Complete
2026-04-03expires 2026-09-01TR-ROW-0426-00397City permit recordRight-of-Way (ROW)The project limits along Grant Rd will extend from the Eastbound Interstate 10 On/Off Ramp intersection to approximately 200 feet east of the east curbline of Fairview Ave for a total length of 0.48 miles. 04/24/2026- Revision for TCP. Permit Renewal Notice Effective July 1, 2026, the Mayor and Council approved and implemented a new fee structure and updated application requirements for right-of-way permits. Permits issued prior to July 1, 2026, under the previous fee structure, are eligible for one final renewal for a maximum of 30 days. The previous 60- and 90-day renewal options are no longer available. If work extends beyond the 30-day renewal period, a new permit application must be submitted. The new application must comply with the current fee structure and include all required project information, including the actual number of days traffic control and/or lane closures will be in place (not the permit duration) and the length × width (L × W) of all pavement cuts.Issued
2026-04-02TR-ROW-0426-00392City permit recordRight-of-Way (ROW)The project limits along Grant Rd will extend from the Eastbound Interstate 10 On/Off Ramp intersection to approximately 200 feet east of the east curbline of Fairview Ave for a total length of 0.48 miles.Void
2025-11-25finaledTR-UTL-1125-02019City permit recordRight-of-Way (ROW) - UtilityPermit is for 13 short-term public notice signs required by the Arizona Corporation Commission providing notice of an approved 138kV transmission line that will be constructed in the area. There will be no impact to traffic, each of the proposed sign locations are located within road right-of-way but clear of all paved surfaces and travel ways. Installation of each sign will take less than 1 hour. Signs will encumber the right-of-way until the approved 138kV electric transmission line is constructed - expected in-service date mid-2027.Complete
2025-10-16finaledTR-ROW-1025-01288City permit recordRight-of-Way (ROW)Traffic control staging and potholing for the design stage of the Grant Rd Underpass job COT job No SR16 COT plan No. I-2022-003 12/02/25 - Request for 30 Day Renewal as of 12/03/2025Complete
2025-09-10finaledTF-FOP-0925-01209City permit recordFire OperationalSlaughterhouse special event/haunted house Liquor license special eventComplete
2025-08-01TD-DEV-0825-00204City permit recordDevelopment PackageRedevelopment of The Slaughterhouse to include new uses and expand provided parking. This project has been previously approved under activity number DP17-0055 which is being revised to show the proposed changes to the approved plans; however, it has been requested to be submitted under a new activity number since the original DP activity number has expired.Fees due
2024-09-10finaledTF-FOP-0924-01034City permit recordFire OperationalHellzapoppin, Slaughterhouse - Circus / tent - special event - organizerComplete

74 older records are not shown here. — each links to its official file.

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (10)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 10 records
DateRecordWhatStatus
2016-08-01T16DV04675Code enforcement caseVegetationComplian
2014-02-10T14DV00762Code enforcement caseCode enforcement caseReferred
2013-09-20T13DV07102Code enforcement caseCode enforcement caseReferred
2010-12-07T10DV08782Code enforcement caseSignComplian
2010-06-10T10DV03833Code enforcement caseRefuseComplian
2009-05-28T09DV03037Code enforcement caseCode enforcement caseComplian
2008-12-12T08DV11343Code enforcement caseGraffitiComplian
2008-07-18T08DV06035Code enforcement caseCode enforcement caseComplian
Show 2 older records
Code enforcement history for this parcel — remaining 2 records
DateRecordWhatStatus
2007-05-31T07DV04927Code enforcement caseGraffitiComplian
2006-11-30T06DV02584Code enforcement caseGraffitiComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 10707018B — 82 permits on file from 2006 to 2026 (21 fireoper, 13 combo, 10 fire operational, 6 row) and 10 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.