Electrical permit history — 1785 W Prince Rd

1785 W Prince Rd, Tucson — built 1987, with 26 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

1785 W Prince Rd

Built 1987 — 1980s commercial stock · last permitted panel/service work 2021 (permit expired without a confirmed final) · HVAC 2008 (finaled)

Parcel
10612017G
Built
1987 (county record)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Convenience Store With Fuel Dispensing
Parcel size
0.40 acres
Building area
2,779 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Service on record
A 2021 permit expired without a confirmed final status; the permit description states “Upgrade existing Electrical Service to 800A, 3PH, 120/208V” — an increase in capacity as described, not a confirmed installed rating.

See the property

County aerial photograph centered on 1785 W Prince Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionPermitted — completion not confirmedA 2021 permit specifies this work (the permit description states “Upgrade existing Electrical Service to 800A, 3PH, 120/208V”), but the available record does not show a final inspection. The permit expired without a confirmed final status. Official status: Expired. T21CM02863 — Upgrade existing Electrical Service to 800A, 3PH, 120/208V
  • Heating, cooling & mechanicalLikely dueLast permitted 2008 (18 years ago). City inspection record: MECHANICAL - FINAL approved 2008-05-01. Contractor of record: CONTEMPORARY REFRIGERATION INC *C. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Equipment from before about 2010 generally runs R-22, which has not been produced since 2020 — repairs mean reclaimed refrigerant at a price that often exceeds replacing the unit. T08ME00047 — REPLACE: 2 NEW 5 TON AC UNITS (APA)
  • Fire alarm & life safetyCurrentLast permitted 2017 (9 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T17FC00540 — Replace two existing Fuel dispensers with New Gilbarco Encore 700s with new hanging hardware. Hydro Testings existing Dispenser Sumps
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    A pool or spa was permitted in 2022. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

Most recent permit on record for this parcel: 2024-08-27 (TF-FCP-0824-00714) — CO2 Detection System for beverage station.

Permit history (26)

Permit history for this parcel — 8 of 26 records
DateRecordWhatStatusValue
2024-08-27finaledTF-FCP-0824-00714City permit recordFire ConstructionCO2 Detection System for beverage stationComplete
2024-08-27finaledTF-FOP-0824-00981City permit recordFire OperationalCO2 Detection System for beverage stationComplete
2023-12-13finaledTR-UTL-1223-03065City permit recordRight-of-Way (ROW) - UtilityCOX TO BORE 88', TRENCH 3', AND OVERLASH 215' FOR SYSTEM TIEComplete
2023-09-22expired 2025-08-25TC-COM-0923-02262City permit recordCommercial BuildingInterior remodel, relocation of Coffee, beverage and checkout area. New Beer cave, backroom area and unisex restroom (45500.00)Inspections
2023-02-27finaledTR-ROW-0223-00439City permit recordRight-of-Way (ROW)CONTRACTOR WILL BE MODIFYING THE INTERSECTION OF ROMERO RD AND PRINCE RD TO NEW TRAFFIC SIGNALS.Complete
2022-09-22finaledT22RW03454City permit recordRight-of-Way (ROW)Job Order Contract (JOC) for Traffic Signal & Street Light Construction, CONTRACT NO. 181906-2 CONTRACTOR WILL BE MODIFYING THE INTERSECTION OF ROMERO RD / PRINCE RD TO NEW TRAFFIC SIGNALS. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. OTHER ACTIVITIES IN AREA, WILL NEED TO COORDINATE TRAFFIC CONTROL SETUP WITH EXISTING SETUP. 1. BUS TOP IN THE AREA, CONTACT SUN TRAN, BEA PAULUS AT 520-26-8826 AND/OR CHRISTINA ROCK AT 520-206-8934 24-HOURS PRIOR TO START OF WORK FOR COORDINATION. 2. PLACE "BUSINESS ACCESS" SIGNS APPROPRIATELY. SEVERAL BUSINESS ALONG ROUTE. 3. INGRESS/EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. 4. ALL AERIAL WORK MUST BE A MINIMUM OF 18-FEET HIGH WHEN CROSSING INTERSECTION, PAVEMENT AND ALLEYS. 5. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE. 6. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION. 7. MAINTAIN PEDESTRIAN ACCESS. 8. IN THE EVENT THAT WEEKEND OR AFTER-HOURS WORK IS INTENDED, CONTACT COT INSPECTION STAFF. IF WOEEDEND WORK, MAKE CONTACT 48-HOURS PRIOR TO THE WEEKEND. DAN ROBERTSON - 520-400-6722.Complete
2022-09-08finaledT22RW03267City permit recordPool / spaRemoval and replacing all existing asphalt on Circle K at 1785 W Prince Road. 2-3 feet of exisitng asphalt falls on the right of way on both Prince Rd entrance and Romero Rd entrance. Asking for the ok to repace there. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRATIVE MANUAL. OTHER ACTIVITIES IN THE AREA, WILL NEED TO COORDINATE TRAFFIC CONTROL SETUP WITH EXISTING SETUP. BUS STOP IN THE AREA, CONTACT SUN TRAN DISPATCH, AT 520-206-8934 AND/OR BEA PAULUS AT 520-206-8826 AT LEAST 48-BUSINESS HOURS PRIOR TO START OF WORK FOR COORDINATION.Final
2021-04-01expired 2021-09-28T21CM02863City permit recordCommercial BuildingUpgrade existing Electrical Service to 800A, 3PH, 120/208VExpired
Show 18 older records
Permit history for this parcel — remaining 18 records
DateRecordWhatStatusValue
2020-11-16expired 2021-05-15T20OT00768City permit recordFence / wall1-CofC PS + 1-ILLUM WALLExpired
2020-07-13expired 2020-11-30T20RW04034City permit recordPool / spaBORE 601' AND PLACE 3- 1.25" INNERDUCT, TRENCH 7' AND PLACE 1- 4" CONDUIT, PLACE 7,885' OF AERIAL CABLE, PLACE (7) DOWN GUYS AND ANCHORS, PLACE (4) 30" x 48" HANDHOLES AND DIG (2) 2'x5' BORE PIT STARTING AT 1825 W PRINCE RD, END AT 1395 W MIRACLE MILE ON PROJECT Z3UFBPG187-TUC_TUC43_001. BUS STOP IN THE AREA, CONTACT SUN TRAN, BEA PAULUS AT 520-206-8826 AND/OR CHRISTINA ROCK AT 520-206-8934 48-HOURS PRIOR TO START OF WORK FOR COORDINATION. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. ALL AERIAL WORK MUST BE A MINIMUM OF 16-FT HIGH. PAVEMENT PATCHING IS NECESSARY WHERE PAVEMENT IS CUT. PATCH LIMITS- THE LIMITS OF THE PAVING SHALL BE A MINIMUM OF 1-FT OUTSIDE THE EXCAVATION. POTHOLES SPACED CLOSELY TOGETHER AND WITHIN 8-FT OF EACH OTHER WILL NEED TO BE JOINED TOGETHER BY ONE SURFACE PATCH. MORATORIUM REQUIREMENTS WILL BE CONVEYED IN THE FIELD BY THE INSPECTOR. BACKFILL WITH CLSM SLURRY OR AGGREGATE BASE COURSE (ABC.) ASPHALTIC CONCRETE USED SHALL BE CITY OF TUCSON MIX NO. 3 OR COT MIX NO. 2 WITH TR-22, INSPECTOR TO ADVISE. REPLACE/ REFRESH ALL STRIPING THAT IS INTERRUPTED BY PATCHES. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION. MAINTAIN PEDESTRIAN ACCESS. MAINTAIN ACCESS TO BUS STOPS AND FOR PEDESTRIAN INGRESS/ EGRESS.Withdrwn
2019-05-07finaledT19RW02541City permit recordROWREPLACE SIGNAL LIGHTS CIP PROJECT-181906 ADDRESS ON APPLICATION- ROMERO RD & PRINCE RD **TRAFFIC CONTROL SET UP SHALL NOT COMMENCE PRIOR TO 9AMFinal
2017-11-08expired 2020-11-29T17OT01162City permit recordFence / wall2 -CHof C ILLUM SIGNS ( 1 WALL + 1 DP)Renewed
2017-09-07finaledT17FO00741City permit recordFIREOPERCARBON DIOXIDE DETECTION SYSTEM INSTALLATION STORE#0483Final
2017-06-30finaledT17FC00540City permit recordFIRECONSReplace two existing Fuel dispensers with New Gilbarco Encore 700s with new hanging hardware. Hydro Testings existing Dispenser SumpsFinal
2017-04-20finaledT17FO00327City permit recordFIREOPERLIST OF FUEL TANKS & PRODUCT STOER #0483Final
2012-08-20expired 2013-02-16T12CM05141City permit recordCOMBOREPLACE DISCONNECT FOR TANKS/DISPENSERSExpired
2012-08-15finaledT12BU00966City permit recordTANKSRE-LINING FIBERGLASS TANKFinal
2008-01-22finaledT08ME00047City permit recordMECHREPLACE: 2 NEW 5 TON AC UNITS (APA)Final
2007-11-01expired 2008-05-03T07ME00736City permit recordMECHREPLACE: A/C UNIT (APA)Expired
2006-10-12finaledT06CM05433City permit recordCOMBOTI:RETAIL CIRCLE KC of o
2005-02-22finaledT05CM00779City permit recordCOMBONEW GAS LINE:ELECTRICAL PANELFinal
2005-01-14finaledT05OT00083City permit recordSIGNSIGN:8332 CIRCLE K #0483Final
2004-07-27finaledT04OT01497City permit recordSIGNSIGN:7515Final
2004-04-27expired 2004-06-26T04EX00358City permit recordEXCAVEXCAV:INSTALL DRIVEWAYClosed
1999-11-02expired 2000-01-01T99EX01293City permit recordEXCAVEXCAV:SIDEWALKClosed
1997-09-18finaledT97EL01510City permit recordELECTCIRCUITS REPLACEMENT FOR FACIA LIGHTINGFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (4)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 4 of 4 records
DateRecordWhatStatus
2020-01-15T20DV00356Code enforcement caseCode enforcement caseComplian
2014-10-06T14DV08351Code enforcement caseSignNoverify
2014-08-08T14DV05902Code enforcement caseSignComplian
2010-08-10finaledT10FR01668Code enforcement caseCode enforcement caseComplete

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 10612017G — 26 permits on file from 1997 to 2024 (3 combo, 2 commercial building, 2 right-of-way (row), 2 pool / spa) and 4 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.