Electrical permit history — 1109 W Prince Rd
1109 W Prince Rd, Tucson — built 1988, with 34 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
1109 W Prince Rd
Built 1988 — 1980s commercial stock · 34 permits on record; no permitted panel/service or HVAC work among them
Permanent link: Electrical permit history for 1109 W Prince Rd (aztucsonelectricalsolutions.com/property/10607010a/1109-w-prince-rd-tucson-az-85705) · Public records last checked 2026-08-17
- Parcel
- 10607010A
- Built
- 1988 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-1
- Assessor use
- Day Care/Pre-School Ctr Private Children
- Parcel size
- 0.76 acres
- Building area
- 7,316 sq ft (assessor record)
- Sewer
- No connection on file (sewer or septic status not confirmed by the record — verify on site)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 fire operational permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyCurrentLast permitted 2022 (4 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T22FC00630 — Fire Alarm & Detection Systems - INSTALL A NAC EXTENDER PANEL, HORN/STROBES AND STROBES, A SMOKE DETECTOR AND A CELLULAR TRANSMITTER.; Fire Alarm Systems - New Sq Ft: 7316; Fire Alarm Systems - # New Stories: 1; Fire Alarm Systems - Monitor Only
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check
Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
A pool or spa was permitted in 2021. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.
Most recent permit on record for this parcel: 2026-03-23 (TF-FOP-0326-00403) — New Discoveries Preschool.
Permit history (34)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2026-03-23finaled | TF-FOP-0326-00403City permit record | Fire OperationalNew Discoveries Preschool | Complete | |
| 2025-03-27finaled | TF-FOP-0325-00410City permit record | Fire OperationalNew Discoveries Preschool Child care facility | Complete | |
| 2024-02-21finaled | TF-FCP-0224-00136City permit record | Fire ConstructionRE-LOCATE 2 EXISTING ALARM STROBES AND CHANGE CANDELA SETTINGS ON 2 HORN/STROBES | Complete | |
| 2024-01-30finaled | TF-FOP-0124-00129City permit record | Fire OperationalNew Discoveries Preschool Child care facility | Complete | |
| 2023-07-05expires 2026-12-17 | TD-DEV-0723-00294City permit record | Development PackageNew shade structures in existing playground | Issued | |
| 2023-03-22finaled | TC-COM-0323-00865City permit record | Commercial BuildingINTERIOR REMODEL WORK ONLY - CLASSROOM #105 NEW NON-BEARING PARTITION & DOOR RELOCATION. REV-1 Extend remodel to Classrooms 107, 109, 111 & 112 NO EXTERIOR WORK PROPOSED. NO CHANGE TO BUILDING SQUARE FOOTAGE, OCCUPANT LOAD OR EXITING. | Complete | |
| 2023-02-02finaled | TF-FOP-0223-00464City permit record | Fire OperationalNew Discoveries Preschool. State Licensed facility capacity 169 | Complete | |
| 2022-09-08finaled | T22FC00630City permit record | Fire ConstructionFire Alarm & Detection Systems - INSTALL A NAC EXTENDER PANEL, HORN/STROBES AND STROBES, A SMOKE DETECTOR AND A CELLULAR TRANSMITTER.; Fire Alarm Systems - New Sq Ft: 7316; Fire Alarm Systems - # New Stories: 1; Fire Alarm Systems - Monitor Only | Complete |
Show 26 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2022-06-22finaled | T22FO00561City permit record | FIREOPER84 PEOPLE | Final | |
| 2022-05-25expired 2023-01-03 | T22FC00364City permit record | Fire ConstructionFire Alarm & Detection Systems - Adding 3 pull stations at the exit.; Fire Alarm Systems - Devices Modified: 3 | Expired | |
| 2022-05-09finaled | T22OT00343City permit record | Commercial BuildingCERTIFICATE OF OCCUPANCY FOR CHILD DAYCARE. NO WORK. | Complete | |
| 2022-02-01finaled | T22FO00112City permit record | FIREOPERPERSONS 117 | Final | |
| 2021-05-28finaled | T21RW02632City permit record | Pool / spaPEDESTRIAN HAWKs PACKAGE 2 RELOCATING FACILITIES IN CONFLICT WITH CITY OF TUCSON PEDESTRIAN HAWK SIGNAL (JOB NO. SH9) PROJECT LOCATED AT PRINCE RD / CRESCENT MANOR AVE. ABANDON 130 LF OF EXISTING 2" STEEL GAS LINE INSTALLATION OF 190 LF OF NEW 2" PE GAS LINE ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. OTHER ACTIVITIES IN THE AREA, WILL NEED TO COORDINATE TRAFFIC CONTROL SETUP WITH EXISTING SETUP. BUS STOP IN THE AREA, CONTACT SUN TRAN DISPATCH, AT 520-206-8934 AND/OR BEA PAULUS AT 520-206-8826 AT LEAST 48-BUSINESS HOURS PRIOR TO START OF WORK FOR COORDINATION. | Final | |
| 2021-04-26finaled | T21FO00252City permit record | FIREOPERTURN YOUR LIFE AROUND | Final | |
| 2020-02-11finaled | T20FO00135City permit record | FIREOPERNEW DISCOVERIES PRESCHOOL - OCC: 117 | Final | |
| 2019-04-29finaled | T19FO00314City permit record | FIREOPEROUTPATIENT TREATMENT | Final | |
| 2019-01-31finaled | T19FO00117City permit record | FIREOPERCHILDCARE CENTER | Final | |
| 2017-11-14finaled | T17CM08489City permit record | COMBOREPL LIKE FOR LIKE SERVICE DISCONNECT REPL MISSING SERVICE UFER | Final | |
| 2009-06-22finaled | T09OT01272City permit record | SIGN16845 | Final | |
| 2008-09-18finaled | T08OT02236City permit record | SIGN15637 | Final | |
| 2007-07-11finaled | T07OT01588City permit record | SIGN13384 | Final | |
| 2007-07-11finaled | T07OT01589City permit record | SIGN13385 | Final | |
| 2007-05-17finaled | T07CM02071City permit record | COMBOTI: COUNSELING | C of o | |
| 2007-05-17finaled | T07CM02072City permit record | COMBOTI: RETAIL | C of o | |
| 2007-04-13 | T07AN00315City permit record | ADDRNEW | Issued | |
| 2005-11-04finaled | T05BU02683City permit record | BUILDFIRE ALARM | Final | |
| 2005-10-27finaled | T05OT02683City permit record | SIGN9968 | Final | |
| 2005-09-19 | T05AN01001City permit record | ADDRNEW | Issued | |
| 2005-09-19finaled | T05CM04777City permit record | COMBOTI: PRESCHOOL | C of o | |
| 2005-01-05finaled | T05OT00017City permit record | SIGNSIGN:YOUNG WORLD LEARNING CENTER | Final | |
| 2004-12-30finaled | T04OT02552City permit record | C-OF-OC OF O:CHILD CARE | C of o | |
| 2002-10-29finaled | T02OT01705City permit record | SIGNSIGN:4677 | Final | |
| 1998-03-04expired 1998-09-16 | T98EL00385City permit record | ELECTELECTRIC SERVICE FOR US WEST | Expired | |
| 1998-03-04expired 1998-05-03 | T98EX00257City permit record | EXCAVEXCAV:SEWER TRENCH:10LF | Closed |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (10)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2010-12-20finaled | T10FR02682Code enforcement case | Fire | Complete |
| 2010-03-15 | T10DV01290Code enforcement case | Code enforcement case | Complian |
| 2009-11-19finaled | T09FR03617Code enforcement case | Fire | Complete |
| 2009-11-09finaled | T09FR03497Code enforcement case | Fire | Complete |
| 2008-10-17 | T08DV09896Code enforcement case | Work without permit | Noverify |
| 2008-07-23finaled | T08FR02103Code enforcement case | Fire | Complete |
| 2008-01-25finaled | T08FR00267Code enforcement case | Code enforcement case | Complete |
| 2006-10-04finaled | T06FR02646Code enforcement case | Code enforcement case | Complete |
Show 2 older records
| Date | Record | What | Status |
|---|---|---|---|
| 2001-06-22 | T01VL01798Code enforcement case | Sign | Complian |
| 2001-01-25 | T01VL00202Code enforcement case | Sign | Complian |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
How this report was built
This is a reading of public records for parcel 10607010A — 34 permits on file from 1998 to 2026 (7 sign, 6 fireoper, 4 fire operational, 4 combo) and 10 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.