Electrical permit history — 3601 N Oracle Rd

3601 N Oracle Rd, Tucson — built 1999, with 26 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

3601 N Oracle Rd

Built 1999 — 1990s commercial stock · 26 permits on record; no permitted panel/service or HVAC work among them

Parcel
10605077A
Built
1999 (county record)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Convenience Store With Fuel Dispensing
Parcel size
0.42 acres
Building area
576 sq ft (assessor record)
Sewer
Connection on file (2000) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 3601 N Oracle Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2024 fire construction permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2024 fire construction permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentA newer 2022 permit for the same system is recorded as “Issued” — The work was permitted, but final completion is not confirmed. The permit description states “Flammable & Combustible Liquid - REPLACE 4 EXISTING MPD FUEL DISPENSERS LIKE FOR LIKE. NO WORK BEYOND SHEAR VALVE.; Other Construction Permit”. Last permitted 2017 (9 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T17FC00991 — INSTALL 1150 UPRIGHT PROPANE TANK DISPENSER.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    A pool or spa was permitted in 2020. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

Recorded sales (2)

Recorded transfers from the Pima County Assessor — 2 of 2
DatePriceType
2007-08-21$550,000Warranty Deed
2003-11-14$500,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2024-10-21 (TF-FCP-1024-00894) — Permit for aboveground vertical 1200 gallon propane tank.

Permit history (26)

Permit history for this parcel — 8 of 26 records
DateRecordWhatStatusValue
2024-10-21finaledTF-FCP-1024-00894City permit recordFire ConstructionPermit for aboveground vertical 1200 gallon propane tankComplete
2024-10-21finaledTF-FOP-1024-01200City permit recordFire OperationalPermit for 1200 gallon aboveground propane tank with liquid dispenserComplete
2022-03-02expired 2023-05-03T22FC00155City permit recordFire ConstructionFlammable & Combustible Liquid - REPLACE 4 EXISTING MPD FUEL DISPENSERS LIKE FOR LIKE. NO WORK BEYOND SHEAR VALVE.; Other Construction PermitIssued
2022-03-02finaledT22FO00203City permit recordFire OperationalFlammable & Combustible Liquid - CE 4 MULTI-PRODUCT FUEL DISPENSERS WITH NEW DISPENSERS, LIKE FOR LIKE. NO WORK BEYOND SHEAR VALVE.; Other Operational PermitComplete
2022-03-02finaledT22CM01537City permit recordCOMBOREPLACE EXISTING FUEL DISPENSER EQUIPMENT WITH NEW LIKE FOR LIKEFinal
2021-09-20finaledT21OT00695City permit recordSIGN2-illum gas canopy signs + EMC added to 2 monusFinal
2021-04-02expired 2022-09-27DP21-0082City permit recordDevelopment PackageSITE - Mobeen Shell, two storage containers (Violation T20DV00382).Issued
2021-02-01finaledT21RW00516City permit recordROWSQUARE CONCRETE PATCH AROUND 3 WATER VALVE BOXES OTHER ACTIVITIES IN THE AREA, WILL NEED TO COORDINATE TRAFFIC CONTROL SETUP WITH EXISTING SETUP.Final
Show 18 older records
Permit history for this parcel — remaining 18 records
DateRecordWhatStatusValue
2020-12-07finaledT20RW06410City permit recordPool / spaNW CORNER OF ORACLE RD & PRINCE RD PAINTED OUT IN WHITE 12'X12' AREA FOR PERM PATCH 3 VALVE BOXES & CONCRETE COLLARS NEED REPLACEMENT @ 10 LF., BUS STOP IN THE AREA, CONTACT SUN TRAN, BEA PAULUS AT 520-206-8826 AND/OR CHRISTINA ROCK AT 520-206-8934 24-HOURS PRIOR TO START OF WORK FOR COORDINATION. PLACE "BUSINESS ACCESS" SIGNS APPROPRIATELY. SEVERAL BUSINESSES ALONG ROUTE. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. PAVEMENT PATCHING IS NECESSARY WHERE PAVEMENT IS CUT. PATCH LIMITS- THE LIMITS OF THE PAVING SHALL BE A MINIMUM OF 1-FT OUTSIDE THE EXCAVATION. POTHOLES SPACED CLOSELY TOGETHER AND WITHIN 8-FT OF EACH OTHER WILL NEED TO BE JOINED TOGETHER BY ONE SURFACE PATCH. BACKFILL WITH CLSM SLURRY OR AGGREGATE BASE COURSE (ABC). ASPHALTIC CONCRETE USED SHALL BE CITY OF TUCSON MIX NO. 3 OR COT MIX NO. 2 WITH TR-22, INSPECTOR TO ADVISE. REPLACE/ REFRESH ALL STRIPING THAT IS INTERRUPTED BY PATCHES. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION. MAINTAIN PEDESTRIAN ACCESS MAINTAIN ACCESS TO BUS STOPS AND FOR PEDESTRIAN INGRESS/ EGRESS.Final
2020-06-12T20CM03628City permit recordCommercial Building2 METAL BOX CONTAINERS ON PROPERTY PER C.E. CASE T20DV00382Expired
2019-12-30finaledT19RW07766City permit recordROWTEP WILL BE REMOVING 1 POLE (134) IN THE ROW A 2'2 HOLE 6' DEEP WILL BE BACKFILLED WITHOUT SIDEWALK IMPACT.Final
2019-10-23finaledT19RW06407City permit recordROWpotholing at various locations at the intersection to determine type, size and depth of existing utilities. approximately 10 potholes in ROW. day or night work to be determined by Tucson Civil and Traffic Inspectors NOTES: SR-77 is permitted through City of Tucson per IGA with ADOT. OVERNIGHT WORK GRANTED ON OCTOBER 30TH - OCTOBER 31ST 2019 7:00 PM - 6:00 AMFinal
2017-12-05finaledT17FC00991City permit recordFIRECONSINSTALL 1150 UPRIGHT PROPANE TANK DISPENSER.Final
2017-09-12finaledT17RW04030City permit recordROWTwo (2) Borings, each to 25ft below pavement. The first starting from the east side of Oracle and proceeding west 100 feet; and then the remaining 400 feet westerly. Each boring has a diameter of 8''.Final
2017-04-07T17CM02732City permit recordCOMBOADD PROPANE TANKWithdrwn
2016-03-30expired 2016-06-21T16EX01071City permit recordEXCAV6 LF AT NW CORNER OF INTERSECTION IN ASPHALT FOR VALVE REPLACEMENTExpired
2006-07-07finaledT06CM03979City permit recordCOMBOREPAIR/ REPLACE DISPENSERSFinal
2006-06-06finaledT06OT01508City permit recordSIGN11290Final
2006-05-02finaledT06OT01170City permit recordC-OF-OC OF O:GAS STATIONC of o
1999-08-19T99PL01835City permit recordPLUMBEXPIREDWithdrwn
1999-05-10expired 2000-02-29T99EL01003City permit recordELECTSIGN:ELECTRIC:9905023Expired
1999-05-03expired 1999-07-02T99EX00464City permit recordEXCAVEXCAV:241 LF OF SIDEWALK:CURB & DRIVE APRONSClosed
1999-04-09expired 1999-10-06T99BU00949City permit recordTANKSTANKSExpired
1999-03-05T99BU00591City permit recordAddition / alterationADDITION:CANOPYVoid
1998-10-20finaledT98BU02563City permit recordGRADINGGRADING:405 CY CUT & 45 CY FILLFinal
1998-10-20finaledT98CM04562City permit recordCOMBOCHEVRON & CONVENIENCE STORE & FUEL PUMPSC of o

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (12)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 12 records
DateRecordWhatStatus
2024-08-02CE-VIO0824-03055Code enforcement caseWork without permitClosed - resolved
2023-10-20CE-VIO1023-06163Code enforcement caseRefuseClosed - resolved
2020-01-16T20DV00382Code enforcement caseCode enforcement caseCourtcmp
2016-11-25T16DV08021Code enforcement caseGraffitiNoverify
2016-10-14T16DV07145Code enforcement caseVegetationNoverify
2015-08-26T15DV06271Code enforcement caseCode enforcement caseComplian
2014-06-26T14DV04212Code enforcement caseCode enforcement caseComplian
2014-02-24T14DV01058Code enforcement caseWork without permitComplian
Show 4 older records
Code enforcement history for this parcel — remaining 4 records
DateRecordWhatStatus
2009-02-18finaledT09FR00631Code enforcement caseCode enforcement caseComplete
2006-08-10finaledT06FR02404Code enforcement caseCode enforcement caseComplete
2001-01-24T01VL00193Code enforcement caseSignComplian
2000-11-30T00VL01839Code enforcement caseSignComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 10605077A — 26 permits on file from 1998 to 2024 (4 combo, 4 row, 2 fire construction, 2 fire operational) and 12 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.