Electrical permit history — 3901 N Oracle Rd

3901 N Oracle Rd, Tucson — built 2004, with 41 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

3901 N Oracle Rd

Built 2004 — 2000s commercial stock · 41 permits on record; no permitted panel/service or HVAC work among them

Parcel
10605003A
Built
2004 (county record)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Store Front Commercial Bldg
Parcel size
2.79 acres
Building area
14,360 sq ft (assessor record)
Sewer
Connection on file (2006) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 3901 N Oracle Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2009 spklr permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2009 spklr permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentA newer 2021 permit for the same system is recorded as “Expired” — The permit expired without a confirmed final status. The permit description states “Automatic Fire Extingshing Sys - STE 100 - Relocate Ten head; Commercial Fire Sprinkler Systems - Modification of heads: 10”. Last permitted 2020 (6 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T20FC00380 — Installation of Sprinkler Monitoring Panel
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    A pool or spa was permitted in 2006. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

Recorded sales (2)

Recorded transfers from the Pima County Assessor — 2 of 2
DatePriceType
2020-02-21$1,356,304Warranty Deed
2008-06-02$3,900,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2021-01-06 (T21FC00007) — Automatic Fire Extingshing Sys - STE 100 - Relocate Ten head; Commercial Fire Sprinkler Systems - Modification of heads: 10.

Permit history (41)

Permit history for this parcel — 8 of 41 records
DateRecordWhatStatusValue
2021-01-06expired 2022-03-09T21FC00007City permit recordFire ConstructionAutomatic Fire Extingshing Sys - STE 100 - Relocate Ten head; Commercial Fire Sprinkler Systems - Modification of heads: 10Expired
2020-12-29expired 2021-09-22T20CM09207City permit recordCommercial BuildingTI: RetailExpired
2020-10-26finaledT20CM07331City permit recordCOMBOTI: RETAIL- ACCESS TO RESTROOMSL of c
2020-09-30finaledT20OT00667City permit recordFence / wall1-ILLUM WALL SIGN AND 1-CofC pole signFinal
2020-06-05finaledT20FC00380City permit recordFIRECONSInstallation of Sprinkler Monitoring PanelFinal
2020-06-02finaledT20RW03150City permit recordROWTEP pole North of 3901 N Oracle Rd, riser down and begin 10' pull through existing 2'' conduit heading West, continue 15' heading South to out of ROWFinal
2020-04-24finaledT20FC00263City permit recordFIRECONSTI - 18 HeadsFinal
2020-02-19finaledT20CM01117City permit recordCOMBOE - TI: INTERIOR ONLY DEMOFinal
Show 33 older records
Permit history for this parcel — remaining 33 records
DateRecordWhatStatusValue
2020-01-02finaledT20CM00002City permit recordCOMBODEMO AND TI OF OFFICESC of o
2010-06-02expired 2010-11-29T10BU00882City permit recordBUILDNEW SLAB & SILOExpired
2009-01-27finaledT09BU00126City permit recordSPKLRAdd 7 fire sprinklersFinal
2008-06-24expired 2011-01-02T08OT01494City permit recordSIGN15188Expired
2008-06-24finaledT08OT01495City permit recordSIGN15189Final
2006-08-25finaledT06BU02157City permit recordPool / spaPOOL:TD#16-22-49Final
2005-03-23expired 2008-12-22T05OT00604City permit recordPool / spaSIGN: ELECTRICAL 8709 BAJA SPAS/ ESCAPE HOME RESOExpired
2005-01-26expired 2008-12-22T05OT00187City permit recordPool / spaSIGN:8405 BAJA SPAS/ESCAPE HOME RESORTExpired
2004-12-08finaledT04BU02941City permit recordPool / spaPOOL:TD#16-22-49Final
2004-10-07T04BU02453City permit recordFence / wallWALL:ARTIFICIAL ROCK POLE COVERSWithdrwn
2004-09-28expired 2008-07-17T04OT01960City permit recordPool / spaSIGN:7852 BAJA SPAS/ESCAPE HOME RESORTExpired
2004-04-23finaledT04BU00992City permit recordSPKLRFIRE SPKR:ADD 13Final
2004-03-04finaledT04CM01025City permit recordCOMBOTI:RETAILC of o
2004-02-06finaledT04BU00262City permit recordSPKLRFIRE SPRINKLER:260'-4" UNDERGROUNDFinal
2004-02-06expired 2004-04-06T04EX00113City permit recordEXCAVTRENCHING 4'D APAClosed
2004-01-15finaledT04OT00080City permit recordSIGNSIGN:6584Final
2004-01-13finaledT04OT00065City permit recordSIGNSIGN:6574Final
2004-01-08finaledT04BU00040City permit recordSPKLRFIRE SPKR:ADD 195Final
2003-11-20expired 2004-03-13T03EX01195City permit recordEXCAVEXCAV:TRENCH FOR WATER SERVICE & FIRE HYDRANTS 60LClosed
2003-09-04finaledT03CM04322City permit recordCOMBONEW:RETAILC of o
2003-01-17expired 2004-10-02T03BU00127City permit recordGRADINGGRADING:500 CY CUT & 2000 CY FILLClosed
2002-10-03T02CM04639City permit recordCOMBOSITEWithdrwn
2002-07-12finaledT02OT01056City permit recordSIGNSIGN:#4194Final
2002-07-08finaledT02OT01012City permit recordSIGNSIGN:4177Final
2002-05-15finaledT02OT00749City permit recordSIGNSIGN:4001Final
2002-03-14finaledT02OT00396City permit recordSIGNSIGN:3758Final
2002-03-11expired 2002-09-08T02OT00368City permit recordSIGNSIGN:2872Withdrwn
2002-03-11expired 2002-11-25T02OT00369City permit recordSIGNSIGN:3741Withdrwn
1998-07-28finaledT98BU01836City permit recordSPKLRFIRE SPKR:RELOC 1Final
1997-06-11P97AN01491City permit recordADDRNEWIssued
1997-06-11finaledT97BU00990City permit recordSPKLRFIRE SPKR RELOC 9 ADD 4Final
1997-06-06P97AN01440City permit recordADDRNEWIssued
1997-06-06finaledT97BU00956City permit recordSPKLRFIRE SPKR:ADD (2)Final

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (9)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 9 records
DateRecordWhatStatus
2017-04-05T17DV01410Code enforcement caseGraffitiComplian
2015-12-24T15DV09856Code enforcement caseRefuseComplian
2014-10-01T14DV08192Code enforcement caseVegetationCourtcmp
2008-09-30T08FR03345Code enforcement caseCode enforcement caseField
2007-09-24T07DV09677Code enforcement caseWork without permitComplian
2005-03-11T05VL00240Code enforcement caseSignComplian
2003-12-18T03VL00987Code enforcement caseSignComplian
1998-09-23T98VL00771Code enforcement caseSignComplian
Show 1 older record
Code enforcement history for this parcel — remaining 1 records
DateRecordWhatStatus
1998-09-21T98VL00747Code enforcement caseSignComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 10605003A — 41 permits on file from 1997 to 2021 (10 sign, 7 spklr, 6 combo, 5 pool / spa) and 9 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.