Electrical permit history — 90 W Fort Lowell Rd

90 W Fort Lowell Rd, Tucson — built 1986, with 79 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

90 W Fort Lowell Rd

Built 1986 — 1980s commercial stock · last permitted panel/service work 2017 (finaled) · HVAC 2004 (finaled)

Parcel
10603100C
Built
1986 (county record)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Retail Strip Center
Parcel size
2.96 acres
Building area
37,622 sq ft (assessor record)
Sewer
Connection on file (2000, 2002, 2009) (county sewer connection records)
Flood zone
AE — Special Flood Hazard Area (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)
Service on record
City records show the 2017 permit was finalized; the permit description states “100 AMP SERVICE UPGRADE” — an increase in capacity as described, not a confirmed installed rating.

See the property

County aerial photograph centered on 90 W Fort Lowell Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionCurrentLast permitted 2017 (9 years ago). City inspection record: ELECTRIC - FINAL approved 2017-02-21. Contractor of record: I P A ELECTRIC LLC. The permit describes an increase in capacity, which is the single best sign the electrical has actually been brought forward. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T17CM00807 — 100 AMP SERVICE UPGRADE
  • Heating, cooling & mechanicalLikely dueLast permitted 2004 (22 years ago). City inspection record: PERMIT FINALED approved 2004-01-21. Contractor of record: AIR EXCELLENCE INC , *T. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Equipment from before about 2010 generally runs R-22, which has not been produced since 2020 — repairs mean reclaimed refrigerant at a price that often exceeds replacing the unit. T04ME00021 — Install a 5 ton gas pack 3 phase no heat strip
  • Fire alarm & life safetyGetting onLast permitted 2011 (15 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T11BU01060 — FIRE ALARM
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    There is an electrical reconnect permit from 2018. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

  • Worth confirming

    A pool or spa was permitted in 2005. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

Recorded sales (1)

Recorded transfers from the Pima County Assessor — 1 of 1
DatePriceType
2016-06-16$1,450,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2026-03-09 (TS-PRM-0326-00090) — 2 E Panel Signs Non Illuminated.

Permit history (79)

Permit history for this parcel — 8 of 79 records
DateRecordWhatStatusValue
2026-03-09expires 2026-11-23TS-PRM-0326-00090City permit recordSign - Permanent2 E Panel Signs Non IlluminatedIssued
2026-01-07finaledTC-CFO-0126-00008City permit recordCertificate of Occupancychange of use to smoke shopComplete
2025-06-27finaledTC-COM-0625-01272City permit recordCommercial Buildingchange of use to smoke shopComplete
2025-04-19TC-COM-0425-00792City permit recordCommercial BuildingFIRE REPAIR TO WALKWAY PATIO COLUMN. THE DAMAGE IS COSMETIC NOT STRUCTURAL. WORK WILL INCLUDE REPLACE DOWNSPOUT, REPLACE SHEATHING AND STUCCO REPAIRWithdrawn
2025-04-02expired 2025-12-30TC-COM-0425-00653City permit recordCommercial BuildingFIRE REPAIR TO WALK WAY PATIO COLUMN. DAMAGE IS COSMETIC NOT STRUCTURAL. WORK INCLUDE REPLACE DOWNSPOUT, REPLACE SHEATHING AND STUCCO AS REQURIED - CE-VIO0325-00948Inspections
2025-03-17finaledTZ-CMP-0325-00046City permit recordZoning Verification Letterzoning compliance requestComplete
2025-03-08TC-COM-0325-00462City permit recordCommercial BuildingRepair to small fire damage to column (non-structural)Withdrawn
2025-02-24finaledTF-FOP-0225-00262City permit recordFire OperationalTentComplete

71 older records are not shown here. — each links to its official file.

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (17)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 17 records
DateRecordWhatStatus
2025-03-04CE-VIO0325-00948Code enforcement caseFireClosed - resolved
2025-01-08CE-VIO0125-00113Code enforcement caseWork without permitClosed - resolved
2019-03-30T19DV02418Code enforcement caseCode enforcement caseComplian
2019-03-18T19DV01898Code enforcement caseCode enforcement caseComplian
2015-05-13T15DV03609Code enforcement caseCode enforcement caseComplian
2014-11-24T14DV09655Code enforcement caseVegetationComplian
2013-04-03T13DV02128Code enforcement caseGraffitiComplian
2010-08-10finaledT10FR01658Code enforcement caseCode enforcement caseComplete
Show 9 older records
Code enforcement history for this parcel — remaining 9 records
DateRecordWhatStatus
2009-08-19finaledT09FR02717Code enforcement caseFireComplete
2009-08-04finaledT09FR02590Code enforcement caseFireComplete
2009-05-18finaledT09FR01720Code enforcement caseCode enforcement caseComplete
2008-09-30T08FR03271Code enforcement caseCode enforcement caseField
2008-05-12finaledT08FR01192Code enforcement caseCode enforcement caseComplete
2007-03-23T07DV02631Code enforcement caseVegetationCancel
2006-05-08finaledT06FR01238Code enforcement caseCode enforcement caseComplete
2006-05-04finaledT06FR01188Code enforcement caseCode enforcement caseComplete
2005-03-25finaledT05FR00406Code enforcement caseCode enforcement caseComplete

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 10603100C — 79 permits on file from 1999 to 2026 (15 sign, 13 combo, 9 c-of-o, 8 commercial building) and 17 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.