Electrical permit history — 3200 N Oracle Rd

3200 N Oracle Rd, Tucson — built 1985, with 27 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

3200 N Oracle Rd

Built 1985 — 1980s commercial stock · HVAC 2025 (finaled)

Parcel
10603087D
Built
1985 (county record)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Convenience Store With Fuel Dispensing
Parcel size
0.46 acres
Sewer
Connection on file (1984, 2018) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 3200 N Oracle Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2026 fire construction permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalCurrentLast permitted 2025 (1 year ago). City inspection record: COT - FCON - Fire - Final approved 2026-06-10. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. TC-COM-0725-01379 — Remove and Replace existing tea and fountain equipment and chiller. Existing C02 to remain. There are no modification to exterior walls, parking, sidewalks or landscape.
  • Fire alarm & life safetyCurrentLast permitted this year (2026). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0226-00079 — Installation of commercial kitchen hood fire suppression system
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Recorded sales (2)

Recorded transfers from the Pima County Assessor — 2 of 2
DatePriceType
2012-04-26$425,000Warranty Deed
1998-05-22$650,000Contract or Agreement

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2026-08-04 (TC-COM-0826-01234) — Closing off 1 side entrance with half wall and windows above..

Permit history (27)

Permit history for this parcel — 8 of 27 records
DateRecordWhatStatusValue
2026-08-04TC-COM-0826-01234City permit recordFence / wallClosing off 1 side entrance with half wall and windows above.In review
2026-06-26TC-COM-0626-00966City permit recordSolar PVInstallation of solar photovoltaic energy generation system on fuel island canopy(ies), including trenching to back exterior wall of store for feeder conductors to utility line side interconnectionNeeds resubmittal
2026-02-08finaledTF-FCP-0226-00079City permit recordFire ConstructionInstallation of commercial kitchen hood fire suppression systemComplete
2025-12-21finaledTC-COM-1225-02299City permit recordAddition / alterationIncludes reorganization of existing kitchen equipment and addition of new fryer units. The existing type 1 hood and wrapped ducts will be replaced with Type 1 new equipment. Rooftop equipment will remain existing.Complete
2025-07-17finaledTC-COM-0725-01379City permit recordFence / wallRemove and Replace existing tea and fountain equipment and chiller. Existing C02 to remain. There are no modification to exterior walls, parking, sidewalks or landscape.Inspections complete
2024-09-26finaledTC-COM-0924-01873City permit recordCommercial BuildingCoffee Wow Phase 2: Updated equipment and millwork to existing coffee bar. Installation of new drain manifold serving the coffee bar. Added dedicated water line and circuit for coffee wow auto clean system. Add glycol chiller and nitrogen generator for nitro coffee.Complete
2024-06-04finaledTR-UTL-0624-01098City permit recordRight-of-Way (ROW) - UtilityP.235785 - Access of ex HH 19659 for splicing/placing, place (1) HH & (1) ped, dig (3) pits, bore 108' and trench 69'Complete
2024-06-03expired 2024-12-10TS-PRM-0624-00254City permit recordSign - PermanentRemove the existing manual price changer and install one new LED electronic price changer as per artwork attachedIssued
Show 19 older records
Permit history for this parcel — remaining 19 records
DateRecordWhatStatusValue
2023-07-12finaledTC-COM-0723-01685City permit recordCommercial BuildingCoffee Wow: equipment and mill work modifications to existing coffee bar and lid barComplete
2021-07-22finaledT21CM05990City permit recordCOMBOLayout and equipment modification to existing full service counter, sales floor, and checkstand.Final
2021-03-15finaledT21RW01193City permit recordROWJOB ORDER CONTRACT FOR TRAFFIC SIGNAL AND STREET LIGHT CONSTRUCTION, CONTRACT NO. 181906-02 TRENCHING FOR ELECTRICAL CONDUIT INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED.Final
2019-11-01T19CM08094City permit recordCommercial BuildingREPLACE EXTERIOR PANEL SYSTEMCanceled
2019-11-01T19CM08095City permit recordCommercial BuildingREPLACE EXTERIOR PANEL SYSTEMCanceled
2019-02-01finaledT19RW00573City permit recordROWStarting from TEP pole on the South side of Fort Lowell riserdown and trench/bore crossing Fort Lowel RD going North trench/bore 109' continue East 36' place Cox ped continue North 4' and pull thru existing. WORK IS BEING DONE ON FORT LOWELL RDFinal
2018-08-15finaledT18RW03678City permit recordROWStarting from TEP pole on the South side of Fort Lowell riserdown and trench/bore crossing Fort Lowel RD going North trench/bore 109' continue East 36' place Cox ped continue North 4' and pull thru existing.Final
2017-12-14finaledT17RW05530City permit recordROWF/H REPLACEMENT ON THE NORTH EAST CORNER IN THE SIDEWALK AND IN DIRTFinal
2015-10-13finaledT15EX03000City permit recordEXCAVINSTALL DRIVEWAY 32' ON FORT LOWELL, SOUTH OF 3200 N ORACLE RD REFERENCE TO T15EX02617Final
2015-05-14expired 2015-07-13T15EX00981City permit recordEXCAVTRICON WILL BE DOING WATER SERVICES, TWO METERS, ONE IS 1" AND THE OTHER IS 2" AND ONE 2" AND ONE 2" & 1" SERVICE CONNECTION WITH A TOTAL OF 20 FEET IN DIRT. WORK ORDER # 2410-226Expired
2015-05-14T15TC01188City permit recordBARRICADTRICON WILL BE DOING WATER SERVICES, TWO METERS, ONE IS 1" AND THE OTHER IS 2" AND ONE 2" AND ONE 2" & 1" SERVICE CONNECTION WITH A TOTAL OF 20 FEET IN DIRT. WORK ORDER # 2410-226Expired
2015-04-10expired 2016-04-17T15OT00485City permit recordSIGNDF WITHIN ROW / TRE CASE # 20-15-046 APPROVED / 2- CHANGEABLE COPY PANELS ON THE N. & S. ELEVS. / 3- ILLUM GAS CANOPY SIGNS ON THE N. S. & E. ELEVS.Expired
2014-12-02finaledT14BU01330City permit recordTANKSINSTALL NEW FUEL TANKSFinal
2014-12-02finaledT14CM08192City permit recordCOMBOQUICKTRIP CANOPYFinal
2014-10-13finaledT14BU01121City permit recordDEMODEMO RETAIL BUILDINGL of c
2014-07-18finaledT14CM04541City permit recordCOMBOCONVENIENCE STOREC of o
2013-11-13finaledDP13-0226City permit recordDevelopment PackageQT STORE #1464Original approved 12/03/2014 1st Revision (As Built) Pages 4,5,6,7,9,10,17,18,Complete
2003-03-04finaledT03OT00332City permit recordSIGNSIGN:5129Final
2002-11-06finaledT02OT01755City permit recordSIGNSIGN:#4720Final

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (6)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 6 of 6 records
DateRecordWhatStatus
2023-02-07CE-VIO0223-01798Code enforcement caseCode enforcement caseClosed - unfounded
2022-02-23T22DV01434Code enforcement caseCode enforcement caseClosed - resolved
2011-02-15T11DV00938Code enforcement caseCode enforcement caseComplian
2009-08-18T09DV04794Code enforcement caseVegetationNoverify
2008-02-12T08DV01107Code enforcement caseSignComplian
2002-09-24T02VL01888Code enforcement caseSignComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 10603087D — 27 permits on file from 2002 to 2026 (4 commercial building, 4 row, 3 combo, 3 sign) and 6 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.