Electrical permit history — 331 W Pastime Rd
331 W Pastime Rd, Tucson — built 1983, with 19 permits on record. Review electrical, HVAC and remodel history with links to official records.
Multifamily property
331 W Pastime Rd
Built 1983 — 1980s multifamily stock · 19 permits on record; no permitted panel/service or HVAC work among them
Permanent link: Electrical permit history for 331 W Pastime Rd (aztucsonelectricalsolutions.com/property/10602240d/331-w-pastime-rd-tucson-az-85705) · Public records last checked 2026-08-16
- Parcel
- 10602240D
- Built
- 1983 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-2
- Assessor use
- Apartments 25 - 99 Units 2 Story
- Parcel size
- 1.39 acres
- Building area
- 31,510 sq ft (assessor record)
- Sewer
- No connection on file (sewer or septic status not confirmed by the record — verify on site)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
There is an electrical reconnect permit from 2020. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.
Recorded sales (4)
| Date | Price | Type |
|---|---|---|
| 2020-11-18 | $4,050,000 | Warranty Deed |
| 2020-02-05 | $2,825,000 | Warranty Deed |
| 2019-01-07 | $2,435,000 | Warranty Deed |
| 2005-12-06 | $2,125,000 | Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2024-09-12 (TR-ROW-0924-01049) — Emergency sewer repair.
Permit history (19)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2024-09-12finaled | TR-ROW-0924-01049City permit record | Right-of-Way (ROW)Emergency sewer repair | Complete | |
| 2024-09-12 | TR-UTL-0924-01732City permit record | Right-of-Way (ROW) - Utilityemergency sewer repair is street | Void | |
| 2024-09-10finaled | TC-COM-0924-01753City permit record | Commercial BuildingInstallation of 4 inch clean out outside in a 4 inch lateral line going to the city main sewer | Complete | |
| 2024-03-22expired 2024-05-05 | TR-ROW-0324-00330City permit record | Right-of-Way (ROW)Remove and replace approx 25LF of curb and sidewalk, No changes, only making repairs because of cracked and decayed existing | Issued | |
| 2021-12-27finaled | T21RW05380City permit record | ROWN.929070-3- ALONG W. PASTIME RD ACCESS HH 13260 TO SPLICE EXISITNG CABLE ADDRESS ON APPLICATION IS 3820 N ORACLE RD | Final | |
| 2020-05-31expired 2021-02-14 | T20CM03317City permit record | Commercial BuildingDECK AND WALKWAY REPAIR | Expired | |
| 2020-02-26finaled | T20CM01297City permit record | Electrical reconnectE- ELECTRICAL RECONNECT (T20DV01098) | Final | |
| 2019-11-05finaled | T19CM08157City permit record | COMBOREPLACE BALCONY STRUCTURE | Final |
Show 11 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2019-08-27finaled | T19RW04689City permit record | ROW2 5X5 bellholes in dirt/blktop front and approx 10 ft trench------ to repair/replace gas line | Final | |
| 2019-05-09finaled | T19RW02619City permit record | ROW54' of bore, 26' of trenching, 287' of aerial placement and new HH #13618 on 331 W. Pastime Rd. Job will also require access to MH #13260 to splice fiber at 321 W. Pastime Rd. | Final | |
| 2018-07-02expired 2019-01-01 | T18CM05172City permit record | COMBOELECTRIC RECONNECT | Expired | |
| 2017-10-25finaled | T17CM08041City permit record | Electrical reconnectELECTRICAL RECONNECT | Final | |
| 2016-03-11finaled | T16CM01897City permit record | COMBORECONNECT ELECTRIC;APT | Final | |
| 2015-04-28finaled | T15CM02796City permit record | COMBOREMOVE ALL EXPOSE WIRE ON ROOF AND REPLACE BURNED RECEPTACLE IN UNIT 105 | Final | |
| 2015-04-09finaled | T15CM02335City permit record | Electrical reconnectELECTRICAL RECONNECT | Final | |
| 2010-05-10finaled | T10EL01096City permit record | ELECTELECTRIC:RECONNECT:APT | Final | |
| 2010-03-04finaled | T10EL00476City permit record | ELECTELECTRIC:RECONNECT APT | Final | |
| 2009-09-30expired 2009-11-29 | T09EX00558City permit record | EXCAVEXCAVATION OF 30' IN ASPHALT ON PASTTIME TO CONSTRUCT ONE MANHOLE AND CONNECT TO SEWER | Closed | |
| 2005-06-29finaled | T05EL01308City permit record | ELECTELECTRIC METER BOX (APA) | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (26)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2026-05-04 | CE-VIO0526-01971Code enforcement case | Code enforcement case | Closed - resolved |
| 2026-01-27 | CE-VIO0126-00457Code enforcement case | Code enforcement case | Closed - resolved |
| 2025-09-22 | CE-VIO0925-04150Code enforcement case | Code enforcement case | Closed - resolved |
| 2024-11-12 | CE-VIO1124-04475Code enforcement case | Code enforcement case | Closed - resolved |
| 2024-09-09 | CE-VIO0924-03619Code enforcement case | Code enforcement case | Closed - resolved |
| 2023-12-13 | CE-VIO1223-06871Code enforcement case | Refuse | Closed - resolved |
| 2023-08-15 | CE-VIO0823-05114Code enforcement case | Refuse | Closed - resolved |
| 2023-03-06 | CE-VIO0323-02233Code enforcement case | Code enforcement case | Closed - resolved |
Show 18 older records
| Date | Record | What | Status |
|---|---|---|---|
| 2020-03-09 | T20DV01701Code enforcement case | Code enforcement case | Complian |
| 2020-01-28 | T20DV00663Code enforcement case | Code enforcement case | Noverify |
| 2019-01-23 | T19DV00407Code enforcement case | Fire | Complian |
| 2018-07-05 | T18DV03865Code enforcement case | Code enforcement case | Complian |
| 2017-02-21 | T17DV00710Code enforcement case | Code enforcement case | Complian |
| 2016-04-08 | T16DV02268Code enforcement case | Code enforcement case | Complian |
| 2016-02-29 | T16DV01080Code enforcement case | Code enforcement case | Complian |
| 2015-04-01 | T15DV02482Code enforcement case | Fire | Complian |
| 2014-08-25 | T14DV06469Code enforcement case | Code enforcement case | Complian |
| 2014-02-10 | T14DV00757Code enforcement case | Code enforcement case | Complian |
| 2010-10-04 | T10DV06814Code enforcement case | Code enforcement case | Noverify |
| 2010-09-20 | T10DV06369Code enforcement case | Code enforcement case | Complian |
| 2010-07-15 | T10DV04640Code enforcement case | Code enforcement case | Noverify |
| 2010-07-14 | T10DV04619Code enforcement case | Code enforcement case | Complian |
| 2008-04-08 | T08DV02869Code enforcement case | Code enforcement case | Complian |
| 2006-10-11 | T06DV01332Code enforcement case | Code enforcement case | Complian |
| 2004-09-27 | T04DV00794Code enforcement case | Code enforcement case | Void |
| 2000-06-05 | T00VL00740Code enforcement case | Code enforcement case | Complian |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, once. No list, no follow-up unless you ask for it.
How this report was built
This is a reading of public records for parcel 10602240D — 19 permits on file from 2005 to 2024 (4 combo, 3 row, 3 electrical reconnect, 3 elect) and 26 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.