Electrical permit history — 3922 N Oracle Rd

3922 N Oracle Rd, Tucson — built 1988, with 40 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

3922 N Oracle Rd

Built 1988 — 1980s commercial stock · 40 permits on record; no permitted panel/service or HVAC work among them

Parcel
10602011F
Built
1988 (county record)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Retail Strip Center
Parcel size
2.27 acres
Building area
27,598 sq ft (assessor record)
Sewer
Connection on file (1989, 2005) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 3922 N Oracle Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 certificate of occupancy permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 certificate of occupancy permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentLast permitted 2021 (5 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T21FC00909 — Add (4) new pendant sprinklers.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    There is an electrical reconnect permit from 2014. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

  • Worth confirming

    A pool or spa was permitted in 2001. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

Most recent permit on record for this parcel: 2025-02-13 (TC-CFO-0225-00028) — 9983 Square feet tenant improvement for a new marijuana dispensary. Lvl 4 TCO so the tenant can start operating while the development package is being completed.

Permit history (40)

Permit history for this parcel — 8 of 40 records
DateRecordWhatStatusValue
2025-02-13finaledTC-CFO-0225-00028City permit recordCertificate of Occupancy9983 Square feet tenant improvement for a new marijuana dispensary. Lvl 4 TCO so the tenant can start operating while the development package is being completedComplete
2024-10-10finaledTF-FCP-1024-00866City permit recordFire ConstructionRelocate 115 pendentsComplete
2024-08-30finaledTR-UTL-0824-01632City permit recordRight-of-Way (ROW) - UtilityBARRICADE: PRJ277142-1: Cox to overlash 1745' to existing aerial and Pull 58' through existing CATV conduit for system tie. **ON ROGER RD**Complete
2024-07-12finaledTD-DEV-0724-00208City permit recordAddition / alterationAddition of drive-thru lane to existing buildingComplete
2024-07-10finaledTC-COM-0724-01337City permit recordCommercial BuildingNew Drive Thru for DispenarayInspections complete
2024-06-29finaledTC-COM-0624-01274City permit recordCommercial Building9983 Square feet tenant improvement for a new marijuana dispensaryComplete
2023-06-21completed 2023-08-24TP-ENT-0623-00028Special exceptionMayor Council Special ExceptionThe applicant is requesting a special exception for a proposed marijuana dispensary within an existing shopping center.Oracle DispensaryOrdinanced
2022-09-08finaledT22FO00765City permit recordFIREOPERSPIRIT HALLOWEEN SUPERSTORES, LLC DBA SPIRIT HALLOWEEN STORE 60941 - 9/10/22 TO 11/2/22.Final
Show 32 older records
Permit history for this parcel — remaining 32 records
DateRecordWhatStatusValue
2021-12-13finaledT21FC00909City permit recordFIRECONSAdd (4) new pendant sprinklers.Final
2021-03-22finaledT21CM02562City permit recordCOMBOgas line repair and pressure testFinal
2021-01-06expired 2022-03-09T21FC00007City permit recordFire ConstructionAutomatic Fire Extingshing Sys - STE 100 - Relocate Ten head; Commercial Fire Sprinkler Systems - Modification of heads: 10Expired
2020-12-29expired 2021-09-22T20CM09207City permit recordCommercial BuildingTI: RetailExpired
2020-12-29finaledT20OT00844City permit recordFence / wall1-ILLUM WALL SIGNFinal
2020-11-05finaledT20FC00759City permit recordFIRECONSTwo Head Re-LocateFinal
2020-09-07finaledT20OT00613City permit recordC-OF-OC OF O: NOR SIDE BRAZILIAN JIU JITSUFinal
2017-06-30expired 2017-09-14T17RW02859City permit recordROWBORE 338' TO PLACE 4" CONDUIT AND PLACE 2-3048 HANDHOLESExpired
2017-01-13finaledT17OT00054City permit recordFence / wall1-ILLUM WALL SIGNFinal
2016-09-23finaledT16CM07351City permit recordCOMBOTI:RETAILC of o
2014-06-10finaledT14CM03549City permit recordCOMBORECONNECT: ELECTRICFinal
2013-11-20expired 2014-05-28T13OT01380City permit recordFence / wall1- ILLUM WALL SIGNExpired
2013-10-28expired 2015-08-05T13CM06564City permit recordCOMBONEW GAS LINEExpired
2011-09-16expired 2011-11-15T11EX00494City permit recordEXCAVREMOVE/REPLACE SIDEWALKClosed
2011-05-06finaledT11OT00894City permit recordSIGN19583Final
2011-02-14finaledT11PL00285City permit recordPLUMBGAS LINE:REPLACE BUSFinal
2010-05-12expired 2011-05-06T10OT01023City permit recordC-OF-OC/O:RESTAURANTExpired
2005-06-30finaledT05OT01624City permit recordSIGNBANNER: 9277 WESTERN DENTALFinal
2005-06-02finaledT05BU01383City permit recordSPKLRFIRE SPKR: ADD 49 RELOCATE 5Final
2004-12-02expired 2005-01-31T04EX01125City permit recordEXCAVTRENCH 8'Closed
2004-10-18finaledT04OT02107City permit recordSIGNSIGN:#7956 WESTERN DENTALFinal
2004-09-24finaledT04BU02359City permit recordSPKLRFIRE SPKR:ADD 45 & INSTALL 140LF OF 4" PIPEFinal
2004-08-20expired 2005-04-17T04CM03843City permit recordCOMBOTI:INTERIOR DEMOClosed
2004-08-19T04AN00794City permit recordADDRNEWIssued
2004-08-13finaledT04CM03735City permit recordCOMBOTI:DENTAL OFFICEFinal
2001-07-25finaledT01BU02173City permit recordSPKLRFIRE SPKR:RELOCATE 14 & ADD 4Final
2001-07-20finaledT01EL01913City permit recordELECTSIGN:ELECTRIC:2766Final
2001-07-10finaledT01BU01990City permit recordBUILDAWNINGFinal
2001-07-10expired 2002-01-06T01EL01780City permit recordELECTELECTRICAL FOR AWNING:T01BU01990Expired
2001-06-22finaledT01CM03118City permit recordPool / spaCHANGE OF OCCUPANCY TI:B-OFFICE TO A2-RESTAURANT 58' x 60' SPACE, METAL STUDS W/ GYP BDC of o
2001-06-08T01AN00522City permit recordADDRNEWIssued
2001-06-08expired 2001-12-05T01CM02832City permit recordCOMBODEMO:INTERIORExpired

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (22)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 22 records
DateRecordWhatStatus
2010-11-17T10DV08400Code enforcement caseCode enforcement caseComplian
2009-11-24T09DV06569Code enforcement caseCode enforcement caseComplian
2009-11-13finaledT09FR03545Code enforcement caseCode enforcement caseComplete
2009-06-12finaledT09FR01945Code enforcement caseFireComplete
2009-02-19finaledT09FR00682Code enforcement caseCode enforcement caseComplete
2009-01-29finaledT09FR00415Code enforcement caseCode enforcement caseComplete
2009-01-07finaledT09FR00047Code enforcement caseFireComplete
2009-01-02finaledT09FR00007Code enforcement caseCode enforcement caseComplete
Show 14 older records
Code enforcement history for this parcel — remaining 14 records
DateRecordWhatStatus
2008-11-24finaledT08FR04411Code enforcement caseFireComplete
2008-11-21finaledT08FR04395Code enforcement caseFireComplete
2008-11-21finaledT08FR04396Code enforcement caseFireComplete
2008-11-21finaledT08FR04398Code enforcement caseFireComplete
2008-09-30finaledT08FR03308Code enforcement caseCode enforcement caseComplete
2007-10-09finaledT07FR02021Code enforcement caseCode enforcement caseComplete
2004-09-01T04ZV00610Code enforcement caseZoningComplian
2004-08-04T04VL00478Code enforcement caseWork without permitReferred
2004-07-29finaledT04FR00210Code enforcement caseCode enforcement caseComplete
2004-07-29T04FR00211Code enforcement caseCode enforcement caseField
2004-07-19finaledT04FR00192Code enforcement caseFireComplete
2004-07-19finaledT04FR00193Code enforcement caseFireComplete
2004-07-19finaledT04FR00194Code enforcement caseFireComplete
1998-09-24T98VL00788Code enforcement caseSignComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 10602011F — 40 permits on file from 2001 to 2025 (7 combo, 3 commercial building, 3 fence / wall, 3 sign) and 22 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.