Electrical permit history — 4146 N Oracle Rd

4146 N Oracle Rd, Tucson — built 1974, with 106 permits on record. Review electrical, HVAC and remodel history with links to official records.

Electrical Property Screening Report · Commercial property

4146 N Oracle Rd

A screening report for electrical planning, assembled from public-record indicators. It is not an official record and every figure in it should be verified against the issuing agency before it is relied on.

Verify parcel data at official source ↗

Built 1974 — 1970s commercial stock · last permitted panel/service work 2015 (finaled)

Is it time to upgrade?

  • Electrical service & distributionFinaled permit foundLast permitted 2015 (11 years ago). Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. T15CM01017 — NEW ELECTRICAL 400AMP
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2021 fire automatic extinguishing system permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyFinaled permit foundLast permitted 2021 (5 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T21FC00815 — relocate 47, add 3 pendent sprinklers.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitized. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    A finaled 2015 panel/service permit is on record for this parcel, which makes it unlikely the original 100–150 A equipment is still in place. That is a permit record, not an inspection — verify the installed rating and the panel brand on site before sizing anything new. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    A pool or spa was permitted in 2004. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

  • Routine

    A trade permit was pulled in 2015. Trade permits cover electrical, plumbing, and mechanical work individually, so some permitted trade work has been done here since.

Solar and energy potential

Roof footprint
≈ 43,271 sq ft (county building-footprint layer, 2 structures)
Usable for solar, planning estimate
≈ 30,300 sq ft (~70% after setbacks, rooftop equipment and access paths)
Array that could fit
on the order of 330 kW — roughly 830 panels (low-tilt ballasted rows, 400 W class modules)
Estimated annual production
≈ 540,000 kWh (PVWatts, Tucson sun, low-tilt south)
Energy-charge offset at TEP commercial rates
$43,000–$70,000 a year (8–13¢/kWh energy + power-supply charges, by season and rate class)

Planning-level arithmetic on the roof area above — not a shading study, a structural review or a design. The offset assumes the building uses the power as it is generated; TEP pays far less (its export rate is about 5¢/kWh) for surplus sent to the grid, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.

TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “Ina Rd and Thornydale Rd”, is about 4.7 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.

Get a commercial solar & switchgear analysis

See the property

Satellite imagery © Google. Imagery can predate recent work and shows nothing about what is inside — context, not evidence.

Flood and drainage

The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; the City of Tucson regulates against its own, and that is the one a permit here is judged against.

The record behind this read

Parcel
10512020C
Year constructed
1974 (assessor record)
Permitting authority
Tucson
Zoning
C-2
Property type
Retail Strip Center
Building area
38,358 sq ft
Service on record
City records show the 2015 permit was finalized; the permit description states “NEW ELECTRICAL 400AMP ”.

The building area above comes from the Pima County Assessor’s record, as we read it on 28 Jan 2026. Each other row names its own source.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What this means for work here

Informational public-record summary — not engineering, inspection, valuation or purchasing advice, and not the official record.

The most recent permitted work on this parcel was in 2026. That says the parcel was worked on under permit, not what the work covered — a roof, a pool or a changeout tells you nothing about the electrical service. Work done without a permit leaves no trace here at all.

What that reading rests on. The issuing offices hold 106 building permits for this parcel dated between 1998 and 2026. By category the work is permanent sign (51), addition / alteration (20), trade permit (12) and annual portable sign compliance (7). 84 of them carry a final inspection; the other 22 were issued, expired or are still open, which is not the same as work completed. There are 7 code-enforcement cases recorded against the parcel, all of them closed. We do not reproduce complaint text — it routinely names people with no connection to the property.

Go straight to the records

Each link opens the issuing office’s own file for that record — dates, scope, status and inspections are theirs to publish, and they are all on the other side of these links.

Read the records yourself. We republish selected facts and record numbers so you can find the file; the issuing agency’s record controls. The files are held by City of Tucson permit record (PRO) ↗ — search the parcel number 10512020C. Permit and parcel information courtesy of the City of Tucson and Pima County; their files are the official record and control over anything summarized here.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Utility and upgrade pathElectric service here is Tucson Electric Power (TEP). A service or panel upgrade needs a TEP meter release and has to meet TEP’s service requirements — meter height and location, clearances, and the point of attachment. See TEP new-service requirements and the TEP standards notes.

In the public record: All commercial property · Commercial property in 85705 · Commercial & industrial reports · Homes in 85705 · Permit data by neighborhood

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

What the flood note is not. The FEMA map linked above is the National Flood Hazard Layer — the federal insurance map. Local floodplain mapping is not reproduced here; use the authority’s own map, linked above. Nothing here is a floodplain determination, an elevation certificate, or a substitute for one. A parcel can straddle a boundary, and a Letter of Map Amendment can remove a structure the map still covers. For a determination, ask the floodplain administrator for the jurisdiction named above; for a design that has to satisfy one, that is work we do.

How this property compares nearby

Properties on N ORACLE RD hold 4,598 City permits on record, 1,059 of them since 2022.

Computed from the same public records as this report — counts and years, not an appraisal.

Complete permit record (113 entries)

Every permit and case we hold for this parcel, newest first. Each number links to the official file.

YearNumberTypeStatus
2026TC-COM-0926-01571Commercial Addition/Alteration PermitSubmitted - Online
2026TS-PRM-0626-00247Permanent Sign PermitIssued
2026TZ-CMP-0526-00094Zoning ComplianceComplete
2026recordRight-of-Way (ROW) Permit - UtilityIn Review
2026TS-PRM-0426-00149Permanent Sign PermitNeeds Resubmittal
2025recordRight-of-Way (ROW) Permit - UtilityNeeds Resubmittal
2025recordRight-of-Way (ROW) Permit - UtilityComplete
2025TP-PRE-0425-00070Pre-Application ConferenceComplete
2024TS-PRM-1024-00445Permanent Sign PermitInspections Complete
2024TZ-CMP-1024-00146Zoning ComplianceComplete
2024TS-TMP-1024-00031Temporary Sign ComplianceIssued
2022T22OT00773Permanent Sign PermitComplete
2022T22DV04153EMERGENCYCOMPLIAN
2021T21OT00895Permanent Sign PermitComplete
2021T21FC00815Fire Automatic Extinguishing System PermitComplete
2021T21CM07321Commercial Addition/Alteration PermitComplete
2021T21CM04518Commercial Addition/Alteration PermitExpired
2021T21FC00121Fire Alarm System PermitExpired
2019T19DV05189REFUSENOVERIFY
2016T16DV02212WEEDSCOMPLIAN
2015T15OT01465Permanent Sign PermitCanceled
2015T15SA00393Zoning ComplianceComplete
2015T15BU00892Commercial Trade PermitComplete
2015T15BU00868Fire Automatic Extinguishing System PermitComplete
2015T15CM02297Commercial Addition/Alteration PermitComplete
2015T15OT00847Permanent Sign PermitCanceled
2015T15CM02868Commercial Trade PermitComplete
2015T15OT00466Permanent Sign PermitCanceled
2015T15CM01017Commercial Trade PermitComplete
2015T15DV00580EMERGENCYCOMPLIAN
2015T15OT00103Permanent Sign PermitComplete
2014T14CM07936Residential Trade PermitComplete
2014T14BU01057Permanent Sign PermitComplete
2014T14DV07407GRAFFITINOVERIFY
2013T13CM06906Residential Trade PermitComplete
2013T13CM05387Commercial Addition/Alteration PermitComplete
2013T13CM04664Commercial Addition/Alteration PermitCanceled
2013T13CM04662Commercial Addition/Alteration PermitComplete
2013DP13-0096Development PackageComplete
2013T13CM02610Commercial Addition/Alteration PermitWithdrawn
2013T13CM01588Commercial Addition/Alteration PermitWithdrawn
2012T12DV07753FIRE AT COMMERCIAL BUILDINGCOMPLIAN
2012T12CM05309Commercial Trade PermitCanceled
2011T11OT01511Annual Portable Sign ComplianceComplete
2011T11DV03169SIGN VIOLATIONCOMPLIAN
2011T11CM00692Commercial Addition/Alteration PermitComplete
2011T11OT00119Permanent Sign PermitComplete
2010T10OT02048Annual Portable Sign ComplianceComplete
2010T10OT02049Annual Portable Sign ComplianceComplete
2010T10OT01825Annual Portable Sign ComplianceComplete
2010T10OT01826Annual Portable Sign ComplianceComplete
2010T10OT01827Annual Portable Sign ComplianceComplete
2010T10OT01828Annual Portable Sign ComplianceComplete
2010T10OT01664Permanent Sign PermitComplete
2010T10BU01302Fire Automatic Extinguishing System PermitComplete
2010T10BU01060Commercial Trade PermitComplete
2010T10BU01006Fire Automatic Extinguishing System PermitComplete
2010T10OT01154Permanent Sign PermitComplete
2010T09CM02946Commercial Addition/Alteration PermitComplete
2010T10EL00906Permanent Sign PermitComplete
2010T09CM03008Commercial Trade PermitComplete
2009T09CM01537Commercial Addition/Alteration PermitCanceled
2007T07CM03341Commercial Addition/Alteration PermitComplete
2007T07OT02229Permanent Sign PermitComplete
2007T07OT00354Permanent Sign PermitComplete
2006T06OT01685Permanent Sign PermitComplete
2006T06OT01593Permanent Sign PermitComplete
2006T06OT01539Permanent Sign PermitComplete
2006T06OT01444Permanent Sign PermitComplete
2006T06OT01368Permanent Sign PermitComplete
2006T06OT01290Permanent Sign PermitComplete
2006T06OT01202Permanent Sign PermitComplete
2006T06CM02341Commercial Trade PermitWithdrawn
2006T06OT01086Permanent Sign PermitComplete
2006T06OT00416Permanent Sign PermitComplete
2006T06OT00341Permanent Sign PermitComplete
2006T06OT00189Permanent Sign PermitComplete
2006T06OT00096Permanent Sign PermitComplete
2005T05OT03205Permanent Sign PermitComplete
2005T05OT03171Permanent Sign PermitComplete
2005T05OT02998Permanent Sign PermitComplete
2005T05CM04442Commercial Addition/Alteration PermitComplete
2005T05OT02545Permanent Sign PermitComplete
2005T05OT02405Permanent Sign PermitComplete
2005T05OT02413Permanent Sign PermitComplete
2005T05OT01691Permanent Sign PermitComplete
2005T05OT01573Permanent Sign PermitComplete
2005T05OT01451Permanent Sign PermitComplete
2005T05OT01308Permanent Sign PermitComplete
2005T05OT01204Permanent Sign PermitComplete
2005T05OT01165Permanent Sign PermitComplete
2005T05OT01102Permanent Sign PermitComplete
2005T05OT00281Permanent Sign PermitComplete
2004T04CM04959Commercial Addition/Alteration PermitComplete
2004T04CM04961Commercial Addition/Alteration PermitComplete
2004T04OT02073Permanent Sign PermitComplete
2004T04OT01726Permanent Sign PermitComplete
2004T04BU01931Fire Automatic Extinguishing System PermitComplete
2004T04CM00162Commercial Addition/Alteration PermitComplete
2004T03CM05762Commercial Addition/Alteration PermitComplete
2003T03OT01488Permanent Sign PermitComplete
2003T03OT01024Permanent Sign PermitWithdrawn
2003T03CM02458Commercial Addition/Alteration PermitWithdrawn
2002T02VL01908Permanent Sign PermitComplete
2002T02OT01269Permanent Sign PermitComplete
2001T01OT00822Permanent Sign PermitComplete
2001T01PL02067Commercial Trade PermitComplete
2001T01CM03218Commercial Addition/Alteration PermitComplete
2001T01OT00409Permanent Sign PermitWithdrawn
2001T01BU01994Fire Automatic Extinguishing System PermitComplete
2000T00VL00392Permanent Sign PermitComplete
1998T98ME01025Commercial Trade PermitCanceled
1998T98PL02005Commercial Trade PermitCanceled

prints this report — permits, comparisons and sources — as a clean document

How this report was built

This is a reading of public records for parcel 10512020C — 106 City permits on file from 1998 to 2026 and 7 code enforcement cases — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive, whose records reach back to the mid-1990s. Some records were still not read for this snapshot: City permit records before the mid-1990s were never fully digitized. The construction year, living area on this page come from our saved copy of the Assessor’s own published data file (dated 2026-01-28). The sewer connection file and the flood map were not read for this snapshot. Absence of a permit here is NOT evidence work was never permitted — it may predate the digitized record or sit in a system this snapshot did not read. Public records snapshot taken 2026-09-22.

The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.