Electrical permit history — 30 E Camino Villas
30 E Camino Villas, Tucson — built 1981, with 8 permits on record. Review electrical, HVAC and remodel history with links to official records.
Multifamily property
30 E Camino Villas
Built 1981 — 1980s multifamily stock · last permitted panel/service work 2026 (finaled)
Permanent link: Electrical permit history for 30 E Camino Villas (aztucsonelectricalsolutions.com/property/10512010b/30-e-camino-villas-tucson-az-85705) · Public records last checked 2026-08-16
- Parcel
- 10512010B
- Built
- 1981 (county record)
- Jurisdiction
- Tucson
- Zoning
- R-3
- Assessor use
- Apartments 5 - 24 Units 2 Story
- Parcel size
- 0.47 acres
- Building area
- 7,360 sq ft (assessor record)
- Sewer
- No connection on file (sewer or septic status not confirmed by the record — verify on site)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
- Service on record
- City records show the 2026 permit was finalized; the permit description states “Need to repair/replace bussing from meter to main breaker in MULTIMETER pack. Emergency as this unit is without power. NO conductors are being changed. Existing SES is a multimeter pack rated at 800A. Individual meters/main breakers are rated at 100A. The bussing that needs repair is the load side of the meter to the 100A breaker and it is rated at 100A.”.
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionCurrentLast permitted this year (2026). City inspection record: COT - LCEL - Electrical Final approved 2026-02-13. Worth reading the permit itself: it names the service but does not read as an increase in capacity, so this may have been a like-for-like replacement rather than an upgrade. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service. TC-COM-0126-00142 — Need to repair/replace bussing from meter to main breaker in MULTIMETER pack. Emergency as this unit is without power. NO conductors are being changed. Existing SES is a multimeter pack rated at 800A. Individual meters/main breakers are rated at 100A. The bussing that needs repair is the load side of the meter to the 100A breaker and it is rated at 100A.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2023 commercial building permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
Multifamily property. House panels, unit meters, and common-area loads are usually metered and maintained separately — worth confirming which side of the meter a problem falls on before scheduling work.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
There is an electrical reconnect permit from 2012. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.
Recorded sales (1)
| Date | Price | Type |
|---|---|---|
| 2005-07-20 | $600,000 | Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2026-01-30 (TC-COM-0126-00142) — Need to repair/replace bussing from meter to main breaker in MULTIMETER pack. Emergency as this unit is without power. NO conductors are being changed. Existing SES is a multimeter pack rated at 800A. Individual meters/main breakers are rated at 100A. The bussing that needs repair is the load side of the meter to the 100A breaker and it is rated at 100A..
Permit history (8)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2026-01-30finaled | TC-COM-0126-00142City permit record | Commercial BuildingNeed to repair/replace bussing from meter to main breaker in MULTIMETER pack. Emergency as this unit is without power. NO conductors are being changed. Existing SES is a multimeter pack rated at 800A. Individual meters/main breakers are rated at 100A. The bussing that needs repair is the load side of the meter to the 100A breaker and it is rated at 100A. | Complete | |
| 2026-01-29finaled | TC-COM-0126-00125City permit record | Commercial BuildingNeed to repair/replace bussing from meter to main breaker in MULTIMETER pack. Emergency as these 2 units are without power | Complete | |
| 2023-05-16finaled | TC-COM-0523-01290City permit record | Commercial Buildingrelocate apartment meter #206 to a different unused meter due to damage to the meter base | Complete | |
| 2023-03-07expired 2023-09-03 | TC-COM-0323-00769City permit record | Commercial BuildingVoid - Duplicate/Same scope of work as existing application permit number TC-COM-1122-00113 FOR APTS. 103, 104, 203 AND 204 . TC-COM-1222-00235 FOR APT. 107. REPAIR DAMAGE TO APARTMENTS CAUSED BY FIRE - BUILDING PERMITS: . ~TC-COM-1122-00113 FOR APTS. 103, 104, 203 AND 204 . ~TC-COM-1222-00235 FOR APT. 107 | Void | |
| 2022-12-05expired 2026-02-02 | TC-COM-1222-00235City permit record | Commercial Building(CE-VIO1122-00363, CE-VIO1122-00360, CE-VIO1122-00364, CE-VIO1122-00359) Repairs to fire damage inside unit | Issued | |
| 2022-11-14expired 2026-02-02 | TC-COM-1122-00113City permit record | Commercial Building(CE-VIO1122-00360, CE-VIO1122-00364, CE-VIO1122-00359, CE-VIO1122-00363) Repairs to fire damage to ceiling and some electrical wiring | Issued | |
| 2012-02-15finaled | T12CM00419City permit record | COMBORECONNECT: ELECTRIC - RES | Final | |
| 2006-03-08finaled | T06EL00464City permit record | ELECTRECONNECT:ELECTRIC APARTMENT | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (12)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2024-01-22 | CE-VIO0124-00297Code enforcement case | Code enforcement case | Closed - resolved |
| 2023-11-15 | CE-VIO1123-06488Code enforcement case | Code enforcement case | Closed - unfounded |
| 2022-11-10closed 2022-11-10 | CE-VIO1122-00360Code enforcement case | Code enforcement case | Closed - Resolved |
| 2022-11-10closed 2022-11-10 | CE-VIO1122-00359Code enforcement case | Code enforcement case | Closed - Resolved |
| 2022-11-10 | CE-VIO1122-00363Code enforcement case | Code enforcement case | Closed - resolved |
| 2022-11-10 | CE-VIO1122-00364Code enforcement case | Code enforcement case | Closed - resolved |
| 2022-05-18 | T22DV03030Code enforcement case | Fire | Complian |
| 2020-11-10 | T20DV07370Code enforcement case | Code enforcement case | Complian |
Show 4 older records
| Date | Record | What | Status |
|---|---|---|---|
| 2016-09-20 | T16DV06014Code enforcement case | Code enforcement case | Complian |
| 2013-05-06 | T13DV02952Code enforcement case | Code enforcement case | Noverify |
| 2012-09-14 | T12DV08566Code enforcement case | Refuse | Noverify |
| 2011-01-07 | T11DV00114Code enforcement case | Refuse | Complian |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Send: the permanent link and the summary above, once. Watch: one email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list either way.
How this report was built
This is a reading of public records for parcel 10512010B — 8 permits on file from 2006 to 2026 (6 commercial building, 1 combo, 1 elect) and 12 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.