Electrical permit history — 4390 N 1st Av

4390 N 1st Av, Tucson — built 1996, with 40 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

4390 N 1st Av

Built 1996 — 1990s commercial stock · 40 permits on record; no permitted panel/service or HVAC work among them

Parcel
10510089H
Built
1996 (county record)
Jurisdiction
Tucson
Zoning
C-2
Assessor use
Convenience Store With Fuel Dispensing
Parcel size
1.13 acres
Building area
5,723 sq ft (assessor record)
Sewer
Connection on file (2006) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 4390 N 1st Av, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 right-of-way (row) permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 right-of-way (row) permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentLast permitted 2020 (6 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T20FC00311 — Installation of a CO2 gas detection alarm.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Most recent permit on record for this parcel: 2025-10-15 (TR-ROW-1025-01285) — 1st Ave Grate Repair: The drainage grate within the roadway just south of the Wetmore & 1st intersection has the potential to damage vehicles. DTM Street Maintenance has requested our help in securing the grate before it becomes more of an issue.

Permit history (40)

Permit history for this parcel — 8 of 40 records
DateRecordWhatStatusValue
2025-10-15finaledTR-ROW-1025-01285City permit recordRight-of-Way (ROW)1st Ave Grate Repair: The drainage grate within the roadway just south of the Wetmore & 1st intersection has the potential to damage vehicles. DTM Street Maintenance has requested our help in securing the grate before it becomes more of an issueComplete
2020-05-11finaledT20FC00311City permit recordFIRECONSInstallation of a CO2 gas detection alarm.Final
2020-05-11finaledT20FO00258City permit recordFIREOPERCO2 MonitoringFinal
2020-03-21expired 2020-09-29T20CM01800City permit recordCommercial BuildingT.I COFFEE SHOPExpired
2019-09-12expired 2020-08-25T19CM06662City permit recordCOMBOE - NEW KITCHEN EQUIPMENT TO MADE TO COOK AREAWithdrwn
2019-06-19finaledT19OT00562City permit recordSIGN6 rebranding signsFinal
2019-05-16finaledT19RW02787City permit recordROWFrom the TEP pole NW corner of 4390 N 1st Ave, begin 1357' overlash heading South, Riser down .Final
2019-04-04finaledT19RW01815City permit recordROWRemove & Replace patch work on 1st Ave at Limberlost and Wetmore Patches - 49’ X15’ / 340’X13’ / 117’x15’ / 60’x13’ / 70’x 13’. JOC JOB3 1710729Final
Show 32 older records
Permit history for this parcel — remaining 32 records
DateRecordWhatStatusValue
2019-03-21finaledT19RW01493City permit recordROWIN THE WEST DIRT SHOULDER, PLACE A 4X4 POTHOLE AND INSTALL NEW COX CABINETFinal
2018-07-31finaledT18FO00602City permit recordFIREOPERCO2 BEVERAGE SYSTEM ALARM(S)Final
2017-12-08T17FO01034City permit recordFIREOPERCO2 - GIANT 6616Void
2017-12-08T17FO01035City permit recordFIREOPERCO2 - GIANT 6615Void
2017-12-08finaledT17FO01051City permit recordFIREOPERFLAM/COMB - GIANT 6616Final
2017-12-08expired 2019-03-05T17FO01052City permit recordFIREOPERFLAM/COMB - GIANT 6615Void
2016-05-06finaledT16OT00563City permit recordFence / wall2 -ILLUM WALL SIGNS & 2- CofC DFFinal
2011-12-13finaledT11CM03792City permit recordCOMBOTI: REMODEL SALES AND COFFEE COUNTER - COMMFinal
2011-09-29finaledT11OT01871City permit recordSIGN45 DAY BANNER 9-4-11 TO 10-18-11Final
2011-08-10finaledT11OT01569City permit recordSIGN19809Final
2011-07-20finaledT11OT01428City permit recordSIGNBANNER; 45 DAY; 07/20/11 - 09/03/11Final
2009-09-02finaledT09OT01854City permit recordSIGN17132Final
2007-08-01finaledT07OT01748City permit recordSIGN13471Final
2007-08-01finaledT07OT01749City permit recordSIGN13469Final
2007-08-01finaledT07OT01750City permit recordSIGN13468Final
2007-06-11finaledT07OT01348City permit recordSIGN13242Final
2007-04-02finaledT07OT00754City permit recordSIGN12885Final
2007-04-02finaledT07OT00756City permit recordSIGN12884Final
2007-03-23finaledT07CM01181City permit recordAddition / alterationADDITION: SIGN AWNINGFinal
2007-01-25finaledT07OT00184City permit recordSIGN12540Final
2007-01-11finaledT07BU00069City permit recordSPKLRFIRE SPKRL: 75 NEWFinal
2006-12-26finaledT06BU02995City permit recordSPKLRFIRE SPRINKLER:ADD 353'-6" NEW 4"Final
2006-11-21finaledT06OT03024City permit recordSIGN12214Final
2006-09-07finaledT06BU02229City permit recordTANKSRERIPE EXISTING FUEL TANKSFinal
2006-08-30T06CM04836City permit recordCOMBOTI: GAS STATIONWithdrwn
2006-04-07finaledT06BU00836City permit recordGRADINGGRADING: 25 CUT 58 FILLFinal
2006-04-06T06AN00409City permit recordADDRNEWIssued
2006-04-06T06BU00834City permit recordGRADINGCUT 25CY FILL 58CYWithdrwn
2006-04-06finaledT06CM01979City permit recordCOMBOCONVENIENCE STORE:REBUILDC of o
2006-04-06finaledT06CM01980City permit recordCOMBOCARWASH :NEWC of o
2006-04-06finaledT06CM01989City permit recordCOMBOSTORAGE BLDG:NEWC of o
2000-08-01finaledT00PL01445City permit recordPLUMBPRIVATE:SEWERFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (5)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 5 of 5 records
DateRecordWhatStatus
2014-07-28T14DV05412Code enforcement caseCode enforcement caseComplian
2011-06-15T11DV04468Code enforcement caseCode enforcement caseComplian
2006-12-19finaledT06FR02903Code enforcement caseCode enforcement caseComplete
2006-11-07finaledT06FR02723Code enforcement caseCode enforcement caseComplete
2006-03-06T06VL00388Code enforcement caseSignComplian

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 10510089H — 40 permits on file from 2000 to 2025 (13 sign, 6 fireoper, 6 combo, 3 row) and 5 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.