Electrical permit history — 800 E Wetmore Rd
800 E Wetmore Rd, Tucson — built 1990, with 35 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
800 E Wetmore Rd
Built 1990 — 1990s commercial stock · 35 permits on record; no permitted panel/service or HVAC work among them
Permanent link: Electrical permit history for 800 E Wetmore Rd (aztucsonelectricalsolutions.com/property/10510088q/800-e-wetmore-rd-tucson-az-85719) · Public records last checked 2026-08-16
- Parcel
- 10510088Q
- Built
- 1990 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-2
- Assessor use
- Office Building 2 Story
- Parcel size
- 2.63 acres
- Building area
- 38,240 sq ft (assessor record)
- Sewer
- No connection on file (sewer or septic status not confirmed by the record — verify on site)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2020 firecons permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2020 firecons permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyCurrentA newer 2020 permit for the same system is recorded as “Expired” — The permit expired without a confirmed final status. The permit description states “Fire Alarm & Detection Systems - NSTALL A FIRE RADIO TO MONITOR THE EXISTING FIRE ALARM PANEL.; Fire Alarm Systems - Monitor Only”. Last permitted 2020 (6 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T20FC00373 — REPLACE THE EXISTING SIMPLEX 4002 FIRE ALARM PANEL WITH THE NEW SIMPLEX 4007 FIRE ALARM PANEL. EXISTING WIRING AND FIELD DEVICES TO REMAIL.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check
Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
- Worth confirming
A pool or spa was permitted in 2021. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.
- Routine
Office and medical tenant improvements are usually limited by available panel spaces and branch circuit capacity, not by the service itself.
Recorded sales (4)
| Date | Price | Type |
|---|---|---|
| 2025-02-28 | $2,400,000 | Warranty Deed |
| 2020-02-03 | $2,457,500 | Warranty Deed |
| 2004-10-01 | $5,525,000 | Special Warranty Deed |
| 2002-12-23 | $3,750,000 | Special Warranty Deed |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2026-03-13 (TC-COM-0326-00365) — The WETMORE TUCSON LLC photovoltaic system will consist of 366 JA Solar 595W modules & 4 grid-tied inverters. The system will supply power through an existing TEP service. Two TEP service will be combined as part of this permit. Modules will be both roof-mounted using racking and on a new steel parking canopy in an existing paved parking area. REV1: This submission revises the location of ground-level PV equipment from the exterior of the building to the interior of the main electrical room..
Permit history (35)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2026-03-13expires 2027-07-09 | TC-COM-0326-00365City permit record | Solar PVThe WETMORE TUCSON LLC photovoltaic system will consist of 366 JA Solar 595W modules & 4 grid-tied inverters. The system will supply power through an existing TEP service. Two TEP service will be combined as part of this permit. Modules will be both roof-mounted using racking and on a new steel parking canopy in an existing paved parking area. REV1: This submission revises the location of ground-level PV equipment from the exterior of the building to the interior of the main electrical room. | Issued | |
| 2026-02-03expires 2029-04-06 | TD-DEV-0226-00030City permit record | Development PackageThe Wetmore Tucson LLC PV system will consist of 366 595W modules & 4 grid-tied inverters. Modules will be roof mounted (252 modules) with racking and mounted on a new steel parking canopy (114 modules). The system will supply power through an existing TEP service. | Issued | |
| 2022-12-12finaled | TZ-CMP-1222-00014City permit record | Zoning Verification LetterZoning Verification Letter Request for the property located at 800 E Wetmore Rd, Tucson, AZ 85719 | Parcel ID (APN): 10510088Q AND 10510089K | Complete | |
| 2021-04-22finaled | T21CM03387City permit record | Pool / spaAdding Sink and Base cabinet into existing space to make a Break Room | L of c | |
| 2020-08-07expired 2022-03-01 | T20FC00521City permit record | Fire ConstructionFire Alarm & Detection Systems - NSTALL A FIRE RADIO TO MONITOR THE EXISTING FIRE ALARM PANEL.; Fire Alarm Systems - Monitor Only | Expired | |
| 2020-06-15finaled | T20OT00429City permit record | SIGN1- SET OF WINDOW VINYL | Final | |
| 2020-06-03finaled | T20FC00373City permit record | FIRECONSREPLACE THE EXISTING SIMPLEX 4002 FIRE ALARM PANEL WITH THE NEW SIMPLEX 4007 FIRE ALARM PANEL. EXISTING WIRING AND FIELD DEVICES TO REMAIL. | Final | |
| 2020-04-16expired 2020-12-08 | T20CM02314City permit record | Commercial BuildingW - MECHANICAL UPGRADE AND NEW EMCS | Expired |
Show 27 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2020-04-06finaled | T20FC00224City permit record | FIRECONSAdding a NAC PAnel, 5 horn strobes and 5 strobes to existing Main Fire Alarm Panel | Final | |
| 2020-04-01finaled | T20FC00211City permit record | FIRECONSTI - Modify 44 | Final | |
| 2020-03-04expired 2020-10-20 | T20CM01475City permit record | Commercial BuildingINTERIOR REMODEL FOR NEW TENANT | Expired | |
| 2019-06-18finaled | T19FC00471City permit record | FIRECONSModify fire sprinkler system to accommodate tenant. | Final | |
| 2019-05-17expired 2020-01-07 | T19CM03504City permit record | COMBOTI: OFFICE | Expired | |
| 2017-09-21expired 2017-11-24 | T17RW04190City permit record | ROWACCESS EXISTING MANHOLE FOR SPLICING ONLY | Expired | |
| 2017-05-23finaled | T17RW02231City permit record | ROWACCESS EXISTING MANHOLE FOR SPLICING ONLY 07/05/2017-PLAN CHANGE ADDING MANHOLE ACCESS ON WETMORE | Final | |
| 2016-11-17 | T16CM08664City permit record | COMBOTI; OFFICE | Withdrwn | |
| 2012-07-18finaled | T12BU00867City permit record | SPKLRRELOCATE 22 FIRE SPRINKLER HEADS AND CHANGE OUT 3 TO QUICK RESPONSE IN UNIT 110 | Final | |
| 2012-07-03finaled | T12CM03953City permit record | COMBOTI: OFFICE | C of o | |
| 2012-04-12 | T12OT00590City permit record | SIGNSIGN | Sign-pc | |
| 2012-04-12 | T12OT00591City permit record | SIGNSIGN | Sign-pc | |
| 2012-03-08finaled | T12BU00326City permit record | BUILDFIRE ALARMS:FIRST:SECOND FLOORS | Final | |
| 2012-02-15finaled | T12BU00222City permit record | SPKLRAdd 47, relocate 8 fire sprinklers | Final | |
| 2012-01-11finaled | T12BU00033City permit record | SPKLRInstall 23 fire sprinklers | Final | |
| 2011-12-19finaled | T11CM03866City permit record | COMBOTI: OFFICE | C of o | |
| 2011-12-19finaled | T11CM03867City permit record | COMBOTI: OFFICE | C of o | |
| 2008-06-25finaled | T08BU01168City permit record | SPKLRInstall 2 new and relocate 3 fire sprinkler heads. | Final | |
| 2005-09-06finaled | T05BU02223City permit record | SPKLRFIRE SPRINKLER:RELOCATE 4:ADD 1 | Final | |
| 2005-09-01finaled | T05OT02180City permit record | SIGNSIGN:9637 MMLA | Final | |
| 2005-06-16 | T05AN00656City permit record | ADDRNEW | Issued | |
| 2005-06-16finaled | T05CM02768City permit record | Pool / spaREMODEL TI: OFFICES TWO SPACES ADDRESSED AS SUITE #205 ON SECOND FLOOR, INCLUDING SUITE #205 AND SUITE #204 ACROSS THE CORRIDOR , METAL STUDS W/ GYP BD, ACCESSIBLE DOOR HARDWARE, VAN ACCESSIBLE PARKING SPACE W/ACCESS AISLE AND LEVEL LANDING W/RAMPS AND VAN ACCESSBLE HANDICAPPED PARKING SIGN. | Final | |
| 2002-06-27finaled | T02BU01853City permit record | SPKLRFIRE SPKR:RELOCATE 46 & ADD 15 | Final | |
| 2002-06-17expired 2003-05-13 | T02CM02929City permit record | COMBOTI:OFFICE | Expired | |
| 1997-10-13finaled | T97BU02110City permit record | SPKLRFIRE SPKR:RELOC 17 & ADD 4 | Final | |
| 1997-09-25expired 1998-09-01 | T97CM03054City permit record | COMBOTI:OFFICE | Expired | |
| 1997-08-28finaled | T97CM02703City permit record | COMBOTI:OFFICE | C of o |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (2)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2011-03-21finaled | T11FR00674Code enforcement case | Code enforcement case | Complete |
| 2008-11-06 | T08FR04247Code enforcement case | Code enforcement case | Field |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Send: the permanent link and the summary above, once. Watch: one email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list either way.
How this report was built
This is a reading of public records for parcel 10510088Q — 35 permits on file from 1997 to 2026 (8 combo, 7 spklr, 4 sign, 4 firecons) and 2 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.