Electrical permit history — 4201 N Oracle Rd

4201 N Oracle Rd, Tucson — built 1990, with 17 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

4201 N Oracle Rd

Built 1990 — 1990s commercial stock · HVAC 2024 (finaled)

Parcel
10409032G
Built
1990 (assessor record)
Jurisdiction
Tucson
Zoning
C-3
Assessor use
Bank
Parcel size
0.72 acres
Building area
2,726 sq ft (assessor record)
Sewer
Connection on file (1978) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 4201 N Oracle Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 fire construction permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalCurrentLast permitted 2024 (2 years ago). City inspection record: COT - LCME - Mechanical Final approved 2024-12-05. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. TC-COM-0224-00243 — Replace 1-7.5 Ton & 1-3 Ton Package Heat Pumps Like for Like in Tonage, Voltage and Same Location with No modifications to Ductwork except on Roof to fit correctly
  • Fire alarm & life safetyCurrentLast permitted 2025 (1 year ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0425-00313 — New FACP Installed.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Most recent permit on record for this parcel: 2025-04-15 (TF-FCP-0425-00313) — New FACP Installed..

Permit history (17)

Permit history for this parcel — 8 of 17 records
DateRecordWhatStatusValue
2025-04-15finaledTF-FCP-0425-00313City permit recordFire ConstructionNew FACP Installed.Complete
2024-08-22expired 2025-02-18TC-COM-0824-01644City permit recordCommercial BuildingVOIDED DUPLICATE PERMIT To Replace 2 Rooftop AC Package UnitsVoid
2024-05-24finaledTC-COM-0524-01005City permit recordAddition / alterationALTERATION LEVEL 3, NEW TELLER LINES, NEW WELLNESS ROOM, MODIFICATION/ADDITION OF OFFICES, MODIFICATION OF RESTROOMS, FINISHESComplete
2024-02-06finaledTC-COM-0224-00243City permit recordCommercial BuildingReplace 1-7.5 Ton & 1-3 Ton Package Heat Pumps Like for Like in Tonage, Voltage and Same Location with No modifications to Ductwork except on Roof to fit correctlyInspections complete
2023-11-30expired 2024-09-29TC-COM-1123-02760City permit recordCommercial BuildingRefresh exterior.Issued
2023-07-17expired 2024-01-13TS-PRM-0723-00419City permit recordSign - PermanentAWNING OVER THE ATMIssued
2023-04-28finaledTS-PRM-0423-00287City permit recordSign - PermanentRemove existing signage and install two (2) sets of illuminated channel letters and pylon sign cabinet and pole coverComplete
2021-02-04expired 2022-01-12T21CM01062City permit recordCommercial BuildingSite Electrical work for new Drive-Up Remote ATM Kiosk at Existing Banking Center.Expired
Show 9 older records
Permit history for this parcel — remaining 9 records
DateRecordWhatStatusValue
2020-10-26expired 2021-06-14DP20-0217City permit recordDevelopment PackageSITE - Bank of America, drive-up remote ATM.Issued
2019-09-13expired 2019-10-23T19RW05185City permit recordROWStarting on the North West side of Oracle and Wetmore heading south for 1200 feet of new aerial coax to the Bank of America on the North West side Oracle and Limberlost.Void
2019-09-12finaledT19RW05153City permit recordROWSTARTING ON THE NORTH WEST SIDE OF ORACLE AND WETMORE HEADING SOUTH FOR 1200 FEET OF NEW AERIAL COAX TO THE BANK OF AMERICA ON THE NORTH WEST SIDE ORACLE AND LIMBERLOST. PERMIT END DATE HAS BEEN MODIFIED DUE TO HOLIDAY RESTRICTION BEGINNING NOVEMBER 28TH 2019 - JANUARY 2ND 2020.Final
2019-05-14finaledT19RW02703City permit recordROWN.539844 443' of bore, 5' of trenching to remove Tele Ped and replace with new Charles Ped. Dig bore and place 3048 HH. Job will also require access to HH#7014 to splice fiber. WORK IS ON LIMBERLOST DRFinal
2019-04-15finaledT19CM02638City permit recordCOMBOREPLACE ATM W/ NEW ATM KIOSK AND ASSOCIATED WORKFinal
2017-08-07expired 2017-10-07T17RW03392City permit recordROWConterra is proposing to Over Lash 4,283' of Aerial Fiber Optic Cable to existing Conterra Fiber on existing TEP/ Century Link PolesExpired
2017-01-26expired 2017-10-03T17CM00669City permit recordCOMBOTI: ADA, FIXTURE AND FINISH TO EXISTING RESTROOM.Expired
2016-02-17finaledT16CM01168City permit recordCOMBOADD EXTERIOR LIGHTINGFinal
2015-08-26finaledT15CM05950City permit recordCOMBOTI: OFFICEFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 10409032G — 17 permits on file from 2015 to 2025 (4 commercial building, 4 row, 4 combo, 2 sign - permanent) — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.