Electrical permit history — 835 W Auto Mall Dr
835 W Auto Mall Dr, Tucson — built 2000, with 6 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
835 W Auto Mall Dr
Built 2000 — 2000s commercial stock · last permitted panel/service work 2025 (permitted, completion not confirmed) · HVAC 2025 (permitted, completion not confirmed)
Permanent link: Electrical permit history for 835 W Auto Mall Dr (aztucsonelectricalsolutions.com/property/10408090e/835-w-auto-mall-dr-tucson-az-85705) · Public records last checked 2026-08-16
- Parcel
- 10408090E
- Built
- 2000 (assessor record)
- Jurisdiction
- Tucson
- Zoning
- C-3
- Assessor use
- Auto/Light Truck Dealership Auto Mall
- Parcel size
- 2.39 acres
- Building area
- 17,671 sq ft (assessor record)
- Sewer
- Connection on file (2013, 2014, 2026) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
- Service on record
- A 2025 permit was issued; completion is not confirmed in the available record; the permit description states “REV1: Updated address New 400amp 480V panel fed from Utility Transfomer. Install (3) Level-3 DCFC at 100amps 480V. Install 30kva step down transformer for 1 Level-2 charger at 100amps 208V”.
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionPermitted — completion not confirmedA 2025 permit specifies this work (the permit description states “REV1: Updated address New 400amp 480V panel fed from Utility Transfomer. Install (3) Level-3 DCFC at 100amps 480V. Install 30kva step down transformer for 1 Level-2 charger at 100amps 208V”), but the available record does not show a final inspection. The work was permitted, but final completion is not confirmed. Official status: Inspections. City inspection record: ENGR Engineering Final approved 2026-02-02. TC-COM-0325-00618 — REV1: Updated address New 400amp 480V panel fed from Utility Transfomer. Install (3) Level-3 DCFC at 100amps 480V. Install 30kva step down transformer for 1 Level-2 charger at 100amps 208V
- Heating, cooling & mechanicalPermitted — completion not confirmedA 2025 permit specifies this work (the permit description states “PROVIDING NEW HVAC AND VENTILATION AT THE EXISTING HONDA SHOP. NO SCOPE OF WORK AT THE SHOWROOM & PARTS STORAGE. NO SITE WORK. NO CHANGE IN OCCUPANCY TYPE. THIS WORK INCLUDES PROVIDING HIGH SPEED DOORS, NEW INSULATION ON WALLS AND ROOF UP TO CODE. THE LEVEL OF ALTERATION WOULD BE LEVEL 1. NOTE: This work is not associated with the PDSD Development Package”), but the available record does not show a final inspection. The work was permitted, but final completion is not confirmed. Official status: Issued. City inspection record: ENGR Engineering Final approved 2026-05-22. TC-COM-0825-01576 — PROVIDING NEW HVAC AND VENTILATION AT THE EXISTING HONDA SHOP. NO SCOPE OF WORK AT THE SHOWROOM & PARTS STORAGE. NO SITE WORK. NO CHANGE IN OCCUPANCY TYPE. THIS WORK INCLUDES PROVIDING HIGH SPEED DOORS, NEW INSULATION ON WALLS AND ROOF UP TO CODE. THE LEVEL OF ALTERATION WOULD BE LEVEL 1. NOTE: This work is not associated with the PDSD Development Package
- Fire alarm & life safetyPermitted — completion not confirmedA 2022 permit specifies this work (the permit description states “Fire Alarm & Detection Systems - Replace the existing fire riser monitor, install a cellular transmitter, a pull, and a smoke detector.; Fire Alarm Systems - New Sq Ft: 5000; Fire Alarm Systems - # New Stories: 1; Fire Alarm Systems - Monitor Only”), but the available record does not show a final inspection. The permit expired without a confirmed final status. Official status: Expired. T22FC00236 — Fire Alarm & Detection Systems - Replace the existing fire riser monitor, install a cellular transmitter, a pull, and a smoke detector.; Fire Alarm Systems - New Sq Ft: 5000; Fire Alarm Systems - # New Stories: 1; Fire Alarm Systems - Monitor Only
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check
Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
Most recent permit on record for this parcel: 2026-04-01 (TF-FCP-0426-00221) — Connecting of monitoring points for existing smoke detectors.
Permit history (6)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2026-04-01finaled | TF-FCP-0426-00221City permit record | Fire ConstructionConnecting of monitoring points for existing smoke detectors | Complete | |
| 2025-12-23 | TC-COM-1225-02309City permit record | Commercial BuildingREMODEL AND EXPANSION TO AN EXISTING AUTOMOTIVE SERVICE SHOP / USED CAR SHOWROOM INTO A SERVICE BUILDING WITH SERVICE SHOP, PARTS STORAGE, TECH AMMENITIES, AND CARWASH. | Needs resubmittal | |
| 2025-08-25expires 2026-11-18 | TC-COM-0825-01576City permit record | Addition / alterationPROVIDING NEW HVAC AND VENTILATION AT THE EXISTING HONDA SHOP. NO SCOPE OF WORK AT THE SHOWROOM & PARTS STORAGE. NO SITE WORK. NO CHANGE IN OCCUPANCY TYPE. THIS WORK INCLUDES PROVIDING HIGH SPEED DOORS, NEW INSULATION ON WALLS AND ROOF UP TO CODE. THE LEVEL OF ALTERATION WOULD BE LEVEL 1. NOTE: This work is not associated with the PDSD Development Package | Issued | |
| 2025-07-09 | TD-DEV-0725-00179City permit record | DemolitionTHIS PROJECT INVOLVES REDEVELOPMENT OF TWO ADJACENT PARCELS LOCATED WITHIN THE TUCSON AUTO MALL: 1. PARCEL 1 - POR. LOT 14, BOOK 40, PAGE 14 - SITE ADDRESS: 835 W. WETMORE ROAD - EXISTING USE: HONDA SERVICE SHOP AND USED CAR SHOWROOM - PROPOSED WORK: REMODEL AND EXPANSION OF THE EXISTING FACILITY 2. PARCEL 2 - LOT 13, BOOK 40, PAGE 14 (TITLE COMMITMENT NO. 1002-385491-RTT) - SITE ADDRESS: 810 W. WETMORE ROAD - EXISTING USE: HONDA SHOWROOM AND SERVICE SHOP - PROPOSED WORK: COMPLETE DEMOLITION OF THE EXISTING STRUCTURE AND CONSTRUCTION OF A NEW HONDA SHOWROOM AND SERVICE DRIVE | Approved - awaiting customer attention | |
| 2025-03-27expired 2026-08-03 | TC-COM-0325-00618City permit record | Commercial BuildingREV1: Updated address New 400amp 480V panel fed from Utility Transfomer. Install (3) Level-3 DCFC at 100amps 480V. Install 30kva step down transformer for 1 Level-2 charger at 100amps 208V | Inspections | |
| 2022-03-29expired 2023-05-03 | T22FC00236City permit record | Fire ConstructionFire Alarm & Detection Systems - Replace the existing fire riser monitor, install a cellular transmitter, a pull, and a smoke detector.; Fire Alarm Systems - New Sq Ft: 5000; Fire Alarm Systems - # New Stories: 1; Fire Alarm Systems - Monitor Only | Expired |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (2)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2011-04-12 | T11DV02476Housing code violation | SIGN VIOLATIONrecorded before 2023 | INVALID |
| 2008-04-17 | T08DV03183Housing code violation | SIGN VIOLATIONNotice of violation issued · recorded before 2023 | COMPLIAN |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Send: the permanent link and the summary above, once. Watch: one email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list either way.
How this report was built
This is a reading of public records for parcel 10408090E — 6 permits on file from 2022 to 2026 (2 fire construction, 2 commercial building, 1 addition / alteration, 1 demolition) and 2 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.