Electrical permit history — 4545 N Oracle Rd

4545 N Oracle Rd, Tucson — built 1989, with 40 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

4545 N Oracle Rd

Built 1989 — 1980s commercial stock · HVAC 2025 (permitted, completion not confirmed) · 1 open code case

Parcel
10408053L
Built
1989 (county record)
Jurisdiction
Tucson
Zoning
C-3
Assessor use
Retail Strip Center
Parcel size
1.08 acres
Building area
12,000 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 4545 N Oracle Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 commercial building permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalPermitted — completion not confirmedA 2025 permit specifies this work (the permit description states “change out 5 HVAC RTU'S. LIKE FOR LIKE. NO STRUCTURAL ALTERATIONS.”), but the available record does not show a final inspection. The work was permitted, but final completion is not confirmed. Official status: Issued. City inspection record: COT - LCME - Mechanical Final approved 2025-08-19. TC-COM-0625-01204 — change out 5 HVAC RTU'S. LIKE FOR LIKE. NO STRUCTURAL ALTERATIONS.
  • Fire alarm & life safetyCurrentLast permitted 2023 (3 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-1223-01448 — Kitchen hood system install systems 1-5
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Worth looking at

    There is an open code enforcement case on this parcel. An open case can hold up a permit, and if it touches unpermitted work the electrical scope usually has to be brought up to code as part of resolving it.

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Recorded sales (1)

Recorded transfers from the Pima County Assessor — 1 of 1
DatePriceType
1998-06-17$1,850,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2025-07-09 (TC-COM-0725-01322) — Partial remodel of the existing Lenscrafters store.

Permit history (40)

Permit history for this parcel — 8 of 40 records
DateRecordWhatStatusValue
2025-07-09finaledTC-COM-0725-01322City permit recordCommercial BuildingPartial remodel of the existing Lenscrafters storeComplete
2025-06-23expired 2026-02-16TC-COM-0625-01204City permit recordAddition / alterationchange out 5 HVAC RTU'S. LIKE FOR LIKE. NO STRUCTURAL ALTERATIONS.Issued
2024-09-16finaledTC-COM-0924-01791City permit recordCommercial BuildingBuilding Permit for Auto Damage - See plans - CE-VIO0824-03481Complete
2024-08-28expired 2025-05-14TC-COM-0824-01686City permit recordCommercial BuildingDamaged store front and gas lineIssued
2024-04-15TF-FCP-0424-00296City permit recordFire ConstructionVOID-Sumbit under Permit#TF-FCP-1223-01406 - New fire alarm System to protect new kitchen hood systems.Void
2024-03-14expired 2024-09-10TS-PRM-0324-00113City permit recordSign - PermanentFabricate & Install Illuminated Pan Channel SignsFees due
2023-12-26finaledTF-FCP-1223-01448City permit recordFire ConstructionKitchen hood system install systems 1-5Complete
2023-12-14finaledTF-FCP-1223-01406City permit recordFire ConstructionNew fire alarm System to protect new kitchen hood systems.Complete
Show 32 older records
Permit history for this parcel — remaining 32 records
DateRecordWhatStatusValue
2023-10-17finaledTC-COM-1023-02445City permit recordCommercial BuildingInterior Remodel Previously Jason's DeliComplete
2021-12-28finaledT21RW05400City permit recordROWW/O# 21R3150 - REPAIR LEAKING MAIN AT THE EAST SIDE EOF THE LOT IN SIDEWALK @ 6 LF. EMERGENCY AFTER THE FACTFinal
2021-11-17T21RW05017City permit recordROWW/O# 21R3150 - REPAIR LEAKING MAIN AT THE EAST SIDE OF THE LOT IN SIDEWALK @ 6 LFVoid
2021-09-16expired 2023-03-15T21OT00686City permit recordFence / wall2-illum wall signsExpired
2021-06-21expired 2022-08-05T21CM05151City permit recordCommercial BuildingTI: RETAILExpired
2020-12-02finaledT20RW06376City permit recordROWREPAIR 4' WATER MAIN LEAK IN SIDEWALK AREA @ 6 LF., "EMERGENCY AFTER THE FACT PERMIT"Final
2018-09-12expired 2020-12-14T18OT00985City permit recordFence / wall2 -illum wall signs+ 1 CofC monu signIssued
2017-08-12expired 2017-10-14T17RW03590City permit recordROWStarting at the TEP Pole on the W. side of Oracle Road overlash 170' going South riser down and trench/bore going West 25' to out of ROW.Expired
2016-07-07expired 2016-08-13T16RW00366City permit recordROWStarting at S/W corner of Limberlost heading W 422' Overlash and contiune N 1,867 Overlash to tie point at 4545 N Oracle RD, riser down pole 25', trench west 25' to out of ROW.Expired
2015-09-14expired 2016-07-24T15OT01226City permit recordFence / wallRE-BRANDING / REMOVE & REPLACE W/ 2- ILLUM WALL SIGNSExpired
2010-06-10expired 2011-02-26T10OT01270City permit recordSIGN18481Expired
2010-06-10finaledT10OT01271City permit recordSIGN18480Final
2007-08-15expired 2008-09-16T07OT01841City permit recordSIGN13520Expired
2007-08-15finaledT07OT01842City permit recordSIGN13519Final
2007-06-13finaledT07OT01392City permit recordSIGN13269Final
2005-08-15finaledT05CM04256City permit recordCOMBOTI:LENS CRAFTERSFinal
2005-03-14finaledT05OT00529City permit recordSIGNSIGN:8657 CINGULAR WIRELESSFinal
2005-01-20finaledT05OT00126City permit recordSIGNSIGN:8367 CINGULAR WIRELESSFinal
2005-01-19finaledT05OT00109City permit recordSIGNSIGN:8354 CINGULAR WIRELESSFinal
2004-10-28DS04-28City permit recordZoning Verification LetterJASONS DELI - DSMR 04-28 4545 N ORACLE RDApproved
2004-09-14expired 2005-10-11T04OT01817City permit recordSIGNSIGN:7749Expired
2003-10-27finaledT03EL02109City permit recordELECTELECTRIC:2 CIRCUITS (APA)Final
2003-08-13finaledT03OT01456City permit recordSIGNSIGN:5888Final
2003-07-30finaledT03OT01385City permit recordSIGNSIGN:5865Final
2003-02-28T03AN00213City permit recordADDRNEWIssued
2003-02-28finaledT03CM01043City permit recordCOMBOTI:RESTAURANTC of o
2002-09-13finaledT02OT01456City permit recordSIGNSIGN:4491Final
2001-12-18finaledT01OT01097City permit recordSIGNSIGN:3451Final
2001-08-03finaledT01OT00259City permit recordSIGNSIGN:2858Final
1997-05-21P97AN01271City permit recordADDRNEWIssued
1997-04-16finaledT97CM00893City permit recordCOMBOTENANT IMPROVEMENT:RETAIL 56X60 METAL STUDS WITH GYP. BD.C of o
1997-04-09finaledT97BU00405City permit recordBUILDITNERIOR DEMO INTERIOR INTERIOR DEMO (REMOVE NONBEARING PARTITIONS)Final

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (17)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 8 of 17 records
DateRecordWhatStatus
2024-08-27CE-VIO0824-03481Code enforcement caseCode enforcement caseActive
2020-07-22T20DV04980Code enforcement caseCode enforcement caseComplian
2011-01-25finaledT11FR00233Code enforcement caseFireComplete
2011-01-19finaledT11FR00185Code enforcement caseFireComplete
2011-01-19finaledT11FR00187Code enforcement caseFireComplete
2010-02-09T10FR00306Code enforcement caseCode enforcement caseField
2010-02-09finaledT10FR00309Code enforcement caseCode enforcement caseComplete
2009-02-12finaledT09FR00598Code enforcement caseFireComplete
Show 9 older records
Code enforcement history for this parcel — remaining 9 records
DateRecordWhatStatus
2009-02-12T09FR00601Code enforcement caseFireField
2009-02-12finaledT09FR00603Code enforcement caseFireComplete
2009-02-03finaledT09FR00462Code enforcement caseCode enforcement caseComplete
2008-10-09finaledT08FR03660Code enforcement caseCode enforcement caseComplete
2008-02-06finaledT08FR00381Code enforcement caseCode enforcement caseComplete
2007-10-09finaledT07FR02020Code enforcement caseCode enforcement caseComplete
2007-09-21T07DV09568Code enforcement caseWork without permitComplian
2006-07-27T06VL01008Code enforcement caseCode enforcement caseComplian
2006-06-26finaledT06FR02097Code enforcement caseCode enforcement caseComplete

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 10408053L — 40 permits on file from 1997 to 2025 (14 sign, 5 commercial building, 5 row, 3 fire construction) and 17 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.