Electrical permit history — 4755 N Oracle Rd
4755 N Oracle Rd, Tucson — built 2006, with 41 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
4755 N Oracle Rd
Built 2006 — 2000s commercial stock · HVAC 2024 (finaled)
Permanent link: Electrical permit history for 4755 N Oracle Rd (aztucsonelectricalsolutions.com/property/10408005f/4755-n-oracle-rd-tucson-az-85705) · Public records last checked 2026-08-17
- Parcel
- 10408005F
- Built
- 2006 (county record)
- Jurisdiction
- Tucson
- Zoning
- C-3
- Assessor use
- Auto/Light Truck Lot Lease/Sale Auto Mall
- Parcel size
- 10.58 acres
- Building area
- 52,305 sq ft (assessor record)
- Sewer
- Connection on file (1993) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
- Historic preservation
- Not on file (City of Tucson HP layers)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2025 fire construction permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalCurrentLast permitted 2024 (2 years ago). City inspection record: COT - LCBU - Building Final approved 2024-12-24. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. TC-COM-0624-01256 — Removal of all restroom fixtures, Floor tile, wall tile, and drywall. New epoxy floor, drywall, and wall tile. New partitions, New restroom fixtures like for like. (NOTE: submit a revision to the permit should any of the following be added as additional work) No plumbing lines will be removed, moved, or altered, No electrical or HVAC work.
- Fire alarm & life safetyCurrentLast permitted 2025 (1 year ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. TF-FCP-0725-00550 — MODIFICATION OF AN EXISTING FIRE ALARM SYSTEM TO RELOCATE AND ADD NOTIFICATION DEVICES TO A TENANT IMPROVEMENT.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
Recorded sales (1)
| Date | Price | Type |
|---|---|---|
| 2006-03-15 | $8,000,000 | — |
Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.
Most recent permit on record for this parcel: 2025-07-08 (TF-FCP-0725-00550) — MODIFICATION OF AN EXISTING FIRE ALARM SYSTEM TO RELOCATE AND ADD NOTIFICATION DEVICES TO A TENANT IMPROVEMENT..
Permit history (41)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2025-07-08finaled | TF-FCP-0725-00550City permit record | Fire ConstructionMODIFICATION OF AN EXISTING FIRE ALARM SYSTEM TO RELOCATE AND ADD NOTIFICATION DEVICES TO A TENANT IMPROVEMENT. | Complete | |
| 2025-06-06finaled | TF-FCP-0625-00459City permit record | Fire Constructionfire sprinkler TI | Complete | |
| 2024-12-31finaled | TC-COM-1224-02438City permit record | Addition / alterationPartial Interior alteration of existing Carmax store | Complete | |
| 2024-06-26finaled | TC-COM-0624-01256City permit record | Addition / alterationRemoval of all restroom fixtures, Floor tile, wall tile, and drywall. New epoxy floor, drywall, and wall tile. New partitions, New restroom fixtures like for like. (NOTE: submit a revision to the permit should any of the following be added as additional work) No plumbing lines will be removed, moved, or altered, No electrical or HVAC work. | Complete | |
| 2024-06-12expired 2024-12-09 | TC-COM-0624-01126City permit record | Fence / wallVOID - Duplicate Application. There is already a permit in process: TC-COM-1222-00324 (4755 N ORACLE RD TUCSON, AZ 85705). Please process your plan review through the permit already in process or request a withdrawal of the existing permit before resubmitting a new application. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/withdraws-and-extensions.pdf For further information, please contact Doris Benoit at doris.benoit@tucsonaz.gov - 520.633.9084 - The scope of work is to removal of all restroom fixtures and accessories, other than fire suppression and electrical. Floor tile, wall tile, and drywall will be removed from walls. New epoxy floor, drywall, and wall tile will be installed. New restroom accessories to include partitions will be installed. New restroom fixtures will be installed like for like. No plumbing lines will be removed, moved, or altered. There is no electrical or HVAC work being done. | Void | |
| 2023-10-18finaled | TF-FCP-1023-01226City permit record | Fire ConstructionInstall a Cell Radio dialer for enhanced communication. It will be powered by battery ad well as electrical plug in. | Complete | |
| 2022-12-19expired 2023-06-17 | TC-COM-1222-00324City permit record | Commercial BuildingInterior renovation to existing Carmax | Withdrawn | |
| 2022-05-09finaled | T22FC00329City permit record | Fence / wallInstall 1-each ceiling mount horn strobe and 1-each wall mount horn strobe for customer TI. | Final |
Show 33 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2022-03-29finaled | T22FC00228City permit record | FIRECONSAdd (14) & Relocate (4) existing pendent sprinklers for new Tenant Finish. | Final | |
| 2021-10-12 | T21CM08055City permit record | COMBOInterior remodel | Void | |
| 2021-10-11finaled | T21CM08028City permit record | COMBOCosmetic Building Remodel | L of c | |
| 2021-10-11finaled | T21CM08027City permit record | COMBOAuto Sales | C of o | |
| 2021-08-11finaled | T21RW03691City permit record | ROWJOC FOR FENCING INSTALLATION & REPAIR CONTRACT # 171759-02 REMOVING AND REPLACING EXISTING 50 LF OF GUARDRAIL AND POSTS. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. MAINTAIN PEDESTRIAN ACCESS. | Final | |
| 2020-09-01 | T20CM05787City permit record | Pool / spaPARTITION INTERIOR SPACE TO CREATE PHOTOBOOTH | Approved | |
| 2020-02-18finaled | T20RW00998City permit record | ROWN.664013 - JOB WILL REQUIRE ACCESS TO MH# AM6 TO SPLICE AND PLACE FIBER | Final | |
| 2019-11-22finaled | T19OT01094City permit record | SIGN4- NON-ILLUM DIRECTIONALS | Final | |
| 2018-11-08finaled | T18OT01167City permit record | Fence / wall1-ILLUM WALL SIGN | Final | |
| 2015-03-05expired 2015-04-30 | T15EX00258City permit record | EXCAV1445 AERIAL WORK, THEN 45LF TRENCH IN DIRT AREA FROM POLE. WEST SIDE OF ORACLE RD. | Closed | |
| 2014-04-24finaled | T14OT00511City permit record | SIGN1- NON-ILLUM DD / 54' SETBACK | Final | |
| 2013-12-03expired 2014-02-01 | T13EX01290City permit record | EXCAVRemove and replace +/- 32 LF of sidewalk and +/- 10 FL of damaged curb around Car Max facility. One location is on Circuit Rd near the intersection Compotition Rd and along Turbo Rd. | Closed | |
| 2008-02-20finaled | T08OT00424City permit record | SIGN14519 | Final | |
| 2007-11-20finaled | T07OT02625City permit record | SIGN14051 | Final | |
| 2007-03-16finaled | T07CM01069City permit record | COMBOINSTALL PAINT BOOTHS | Final | |
| 2007-03-05finaled | T07BU00488City permit record | TANKSINST 3 ABOVE GROUND OIL TANKS | Final | |
| 2007-01-17expired 2007-03-18 | T07EX00033City permit record | EXCAVREMOVE EXISTING DRIVEWAY & CLOSE CURB OPENING | Closed | |
| 2007-01-17finaled | T07OT00129City permit record | SIGN12502 | Final | |
| 2007-01-17finaled | T07OT00130City permit record | SIGN12503 | Final | |
| 2006-11-21finaled | T06BU02759City permit record | BUILDFIRE ALARM FOR NEW CAR DEALERSHIP (CARMAX) | Final | |
| 2006-11-16finaled | T06OT02988City permit record | SIGN12186 | Final | |
| 2006-11-01expired 2006-12-31 | T06EX01089City permit record | EXCAVEXCA:94.5' NEW PROTECTED MAIN TO CONNECT WATER | Closed | |
| 2006-10-30expired 2006-12-29 | T06EX01083City permit record | EXCAVPARTIALLY CLOSE EXIST ENT. & PROVIDE NEW ENG | Closed | |
| 2006-10-04finaled | T06BU02413City permit record | TANKSNEW UNDERGROUND FUEL TANK | Final | |
| 2006-10-02finaled | T06BU02378City permit record | SPKLRFIRE SPRNKLER:300LF OF 6" UNDERGROUND | Final | |
| 2006-09-12finaled | T06BU02266City permit record | SPKLRADD 636 NEW FIRE SPRINKLERS | Final | |
| 2006-08-11finaled | T06PL01455City permit record | PLUMBPRIVATE SEWER | Final | |
| 2006-05-24finaled | T06BU01298City permit record | DEMODEMO: RETAIL BUILDING | Final | |
| 2006-05-04expired 2007-10-13 | T06BU01096City permit record | GRADINGGRADING: CUT 6736 CY FILL 1649 CY | Si_xpire | |
| 2006-04-20finaled | T06CM02281City permit record | COMBONEW: SALES AND SERVICE (COSMETIC CARWASH) | C of o | |
| 2006-04-19 | T06AN00441City permit record | ADDRNEW | Issued | |
| 2006-04-19finaled | T06CM02252City permit record | COMBONEW: RETAIL AUTO SALES & SERVICE OFFICES / SALES = 177 OCC SERVICE = 112 OCC | C of o | |
| 2005-08-25expired 2006-09-14 | D05-0031City permit record | Development PackageCARMAX | Approved |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Code enforcement (7)
Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.
| Date | Record | What | Status |
|---|---|---|---|
| 2025-09-22 | CE-VIO0925-04129Code enforcement case | Code enforcement case | Closed - unfounded |
| 2011-04-29finaled | T11FR00951Code enforcement case | Code enforcement case | Complete |
| 2011-01-04finaled | T11FR00023Code enforcement case | Fire | Complete |
| 2010-05-06finaled | T10FR00916Code enforcement case | Code enforcement case | Complete |
| 2009-03-06finaled | T09FR00828Code enforcement case | Fire | Complete |
| 2008-11-13finaled | T08FR04313Code enforcement case | Code enforcement case | Complete |
| 2007-08-31finaled | T07FR01716Code enforcement case | Code enforcement case | Complete |
Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
How this report was built
This is a reading of public records for parcel 10408005F — 41 permits on file from 2005 to 2025 (7 sign, 6 combo, 5 excav, 3 fire construction) and 7 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.