Electrical permit history — 3951 N Benan Venture Dr

3951 N Benan Venture Dr, Tucson — built 2001, with 15 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

3951 N Benan Venture Dr

Built 2001 — 2000s commercial stock · 15 permits on record; no permitted panel/service or HVAC work among them

Parcel
103090760
Built
2001 (county record)
Jurisdiction
Tucson
Zoning
I-1
Assessor use
Warehousing Planned Industrial Park
Parcel size
4.08 acres
Building area
44,061 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)
Historic preservation
Not on file (City of Tucson HP layers)

See the property

County aerial photograph centered on 3951 N Benan Venture Dr, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2022 firecons permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2022 firecons permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyCurrentLast permitted 2022 (4 years ago). Panels and devices age out on their own schedule, and the code moves underneath them — a system that was compliant when installed is not automatically compliant now. T22FC00306 — Existing Fire Alarm monitoring from land lines to wireless via DSC Dialer.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. We read the City of Tucson’s own permit file, not a recent extract of it — back to about 2006, and into the 1990s on properties with that much history. Microfiche before then was never fully digitised. Every record links to the city’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Industrial and warehouse space usually means three-phase motor loads. High-bay LED retrofits and added VFDs both change the load picture.

Recorded sales (2)

Recorded transfers from the Pima County Assessor — 2 of 2
DatePriceType
2005-06-15$2,700,000Special Warranty Deed
2000-11-01$637,205Special Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2026-06-23 (TC-COM-0626-00945) — Add HVLS Big Ass Fans.

Permit history (15)

Permit history for this parcel — 8 of 15 records
DateRecordWhatStatusValue
2026-06-23expires 2027-07-23TC-COM-0626-00945City permit recordCommercial BuildingAdd HVLS Big Ass FansIssued
2022-04-27finaledT22FC00306City permit recordFIRECONSExisting Fire Alarm monitoring from land lines to wireless via DSC Dialer.Final
2017-06-23finaledT17RW02757City permit recordROWSTARTING AT COX PED HEADING NORTH TRENCH IN DIRT 492' CROSSING TWO DRIVEWAYS TO COX PED CONTINUE GOING WEST 20' TO OUT OF ROWFinal
2017-01-12expired 2017-06-09T17RW00216City permit recordROWTrench 110' in asphalt and restore approx 220' sq ft of asphalt, trench 10' in dirt to place conduit and to access manhole. Replacing a 1248 ped with a Big Shot ped. WORK ORDER # N.191637Expired
2013-05-21finaledT13CM03098City permit recordCOMBOOFFICE/STORAGEC of o
2013-05-14expired 2013-11-16T13OT00582City permit recordFence / wall1- ILLUM WALL SIGNExpired
2010-11-30finaledT10CM03325City permit recordCOMBOPALLET RACKFinal
2010-11-12expired 2011-08-02T10CM03187City permit recordCOMBOTI: OFFICE WAREHOUSE AND C OF OSi_xpire
Show 7 older records
Permit history for this parcel — remaining 7 records
DateRecordWhatStatusValue
2010-03-16expired 2010-09-15T10BU00436City permit recordSPKLRINSTALL 361 NEW FIRE SPRINKLER HEADS.Expired
2006-10-11finaledT06OT02640City permit recordSIGN11974Final
2006-06-06T06AN00608City permit recordADDRNEWIssued
2006-06-06finaledT06EL01076City permit recordELECTADD ELEC METERFinal
2006-05-11finaledT06BU01143City permit recordSPKLRSPRNKLR: ADD 15 NEWFinal
2005-11-30T05AN01272City permit recordADDRNEWIssued
2005-11-30finaledT05CM05958City permit recordCOMBOTI:WAREHOUSEC of o

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Code enforcement (2)

Code cases and housing-code violations recorded against this parcel, by category. Closed cases stay on the record, and most of these are closed — check the status column. We show the category and the official record number rather than the complaint text, which often names people who have nothing to do with the property.

Code enforcement history for this parcel — 2 of 2 records
DateRecordWhatStatus
2022-03-24T22DV02021Code enforcement caseRefuseNoverify
2014-07-11T14DV04683Code enforcement caseSignNoverify

Record numbers link to the City of Tucson’s official file. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 103090760 — 15 permits on file from 2005 to 2026 (4 combo, 2 row, 2 spklr, 2 addrnew) and 2 code enforcement cases — assembled from the Pima County parcel file, the City of Tucson’s Property Research Online file (permits back to about 2006, further on some parcels), and the City’s GIS permit and code-enforcement layers (2022 onward). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.