Electrical permit history — 5375 S I19 Frontage Rd

5375 S I19 Frontage Rd, Tucson — built 1901, with 33 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

5375 S I19 Frontage Rd

Built 1901 — 1900s commercial stock · 33 permits on record; no permitted panel/service or HVAC work among them

Parcel
304690440
Built
1901 (assessor record)
Jurisdiction
Unincorporated Pima County
Zoning
RH
Assessor use
County Residential Property
Parcel size
60.70 acres
Building area
21,099 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
AE — Special Flood Hazard Area (FEMA)
Historic preservation
Canoa Ranch Rural Historic Landscape — National Register district (Pima County) (City of Tucson)

See the property

County aerial photograph centered on 5375 S I19 Frontage Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2021 addition / alteration permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2021 addition / alteration permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. This parcel is in unincorporated Pima County, so we read the county’s own permit system — including its historical permits, which reach back into the 1990s where they exist. Every record links to the county’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    There is an electrical reconnect permit from 2018. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

Most recent permit on record for this parcel: 2024-06-26 (P24FC00559) — Commercial Building New.

Permit history (33)

Permit history for this parcel — 8 of 33 records
DateRecordWhatStatusValue
2024-06-26P24FC00559Pima County permitFloodplain UseCommercial Building NewVoid
2024-05-31P24BP05356Pima County permitBuildingCommercial Building NewPermit Expired
2024-03-22P24RW00368Pima County permitRight of WayI19 FRONTAGE - I-19 Frontage and Historic Canoa RanchWithdrawn
2021-12-02P21FC01122Pima County permitFloodplain UseADDIssued
2021-12-01finaledP21BP12181Pima County permitAddition / alterationCommercial Building AlterationC of O
2020-10-14P20BP06355-01Pima County permitAddition / alterationCommercial Building Addition - RevisionApproved
2020-09-17P20BP06355Pima County permitAddition / alterationCommercial Building AdditionPermit Expired
2020-09-01finaledP20BP05924Pima County permitOther StructuresSignFinal
Show 25 older records
Permit history for this parcel — remaining 25 records
DateRecordWhatStatusValue
2019-11-08P19FC00727Pima County permitFloodplain UseADDIssued
2019-11-08finaledP19BP07240Pima County permitAddition / alterationCommercial Building AlterationC of O
2019-09-09P19BP05659Pima County permitElectrical / mechanicalElectrical EquipmentApplication Expired
2019-07-19P19BP04493Pima County permitElectrical / mechanicalElectrical EquipmentVoid
2019-05-24P19BP03223Pima County permitBuildingCommercial Building OtherIssued
2018-03-07finaledP18BP01588Pima County permitElectrical / mechanicalElectrical ReconnectFinal
2017-10-11P17BP04889-01Pima County permitRevisionCommercial Building Other - RevisionApproved
2017-08-03finaledP17BP04889Pima County permitBuildingCommercial Building OtherFinal
2015-10-07finaledP15BP06655Pima County permitElectrical / mechanicalElectrical EquipmentFinal
2015-10-07finaledP15BP06652Pima County permitElectrical / mechanicalElectrical EquipmentFinal
2015-07-27P15BP05067Pima County permitElectrical / mechanicalElectrical EquipmentPermit Expired
2015-07-27P15BP05066Pima County permitElectrical / mechanicalElectrical Equipment - ELECTRIC UPGRADEPermit Expired
2015-07-26P15BP05058Pima County permitBuildingCommercial Building OtherApproved
2015-07-26P15BP05015Pima County permitElectrical / mechanicalElectrical Equipment - ELECTRIC UPGRADEApplication Expired
2012-10-02finaledP12CP05779Pima County permitBuildingCOMBO/COTH -Final
2012-04-09finaledP12CP02040Pima County permitBuildingCOMBO/CTI -C of O
2012-04-09finaledP12CP02038Pima County permitBuildingCOMBO/CTI -C of O
2012-04-09finaledP12CP02036Pima County permitBuildingCOMBO/CTI -C of O
2012-04-09finaledP12CP02033Pima County permitBuildingCOMBO/CTI -C of O
2009-08-25finaledP09CP05005Pima County permitBuildingCOMBO/CALT -Final
2007-05-31P07CP05248Pima County permitHistoricalCOMBO/CALT -Expired
2007-01-09finaledP07CP00212Pima County permitHistoricalCOMBO/CADD -Final
2005-05-26finaledP05CP06315Pima County permitHistoricalCOMBO/CALT -C of O
2005-05-26finaledP05CP06316Pima County permitHistoricalCOMBO/CALT -C of O
1998-03-11P98CP02302Pima County permitHistoricalMH/MBLE -Application Expired

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Showing the 33 most recent county records — this parcel has more. The full set is on Pima County’s permit portal (search the parcel number).

Record numbers link to the issuing office’s official file — Pima County’s portal for county permits, the City of Tucson’s for city records. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 304690440 — 33 permits on file from 1998 to 2024 (10 building, 8 electrical / mechanical, 5 historical, 4 addition / alteration) — assembled from the Pima County parcel file, the City of Tucson GIS layers, and Pima County’s Accela permit portal (searched by parcel and by address, because the county’s parcel links break on older records). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.