Electrical permit history — 7900 N La Canada Dr

7900 N La Canada Dr, Tucson — built 2000, with 22 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

7900 N La Canada Dr

Built 2000 — 2000s commercial stock · 22 permits on record; no permitted panel/service or HVAC work among them

Parcel
22549073P
Built
2000 (assessor record)
Jurisdiction
Unincorporated Pima County
Zoning
CR-5
Assessor use
Assisted Living Facility Licensed
Parcel size
7.93 acres
Building area
222,779 sq ft (assessor record)
Sewer
Connection on file (2000, 2001) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)

See the property

County aerial photograph centered on 7900 N La Canada Dr, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2001 damage/demo permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2001 damage/demo permit is on file — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. This parcel is in unincorporated Pima County, so we read the county’s own permit system — including its historical permits, which reach back into the 1990s where they exist. Every record links to the county’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    A pool or spa was permitted in 2000. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

Most recent permit on record for this parcel: 2025-09-05 (P25BP06699) — Tenant Improvement — Mountain View Retirement Village Modification.

Permit history (22)

Permit history for this parcel — 8 of 22 records
DateRecordWhatStatusValue
2025-09-05P25BP06699Pima County permitBuildingTenant Improvement — Mountain View Retirement Village ModificationDeficient
2020-01-14P20BP00268Pima County permitAddition / alterationCommercial Building AlterationApplication Expired
2019-12-17P19BP06058-01Pima County permitAddition / alterationCommercial Building Alteration - RevisionApproved
2019-09-24P19BP06058Pima County permitAddition / alterationCommercial Building AlterationExpired
2008-11-18P08CP08304Pima County permitHistoricalSIGN/SIGN -Withdrawn
2001-02-21finaledP01CP01693Pima County permitDamage/DemoDEMO/CDMO -Final
2001-02-08finaledP01CP01302Pima County permitHistoricalCOMBO/CADD - — THE BRIDGE @ MOUNTAIN VIEWFinal
2001-01-16finaledP01CP00390Pima County permitHistoricalSIGN/SIGN - — THE BRIDGE @ AT MTN VIEW D/P20/22Final
Show 14 older records
Permit history for this parcel — remaining 14 records
DateRecordWhatStatusValue
2000-12-20finaledP00CP12963Pima County permitHistoricalCOMBO/COTH -Final
2000-11-22finaledP00CP11983Pima County permitPool / spaPOOL/SPA/PSEM - — THE BRIDGE AT MOUNTAIN VIEW DP 20/22Final
2000-08-30P00CP08835Pima County permitHistoricalMODULAR/COTH - — LA CANADA ESTATESExpired
2000-05-30P00CP05541Pima County permitHistoricalPLUMB/COTH -Expired
2000-05-12P00CP05019Pima County permitHistoricalCOMBO/COTH - — THE BRIDGE AT MOUNTAIN VIEW APARTMENTSExpired
2000-03-02P00CP02248Pima County permitHistoricalPLUMB/COTH -Expired
2000-01-31P00RW00244Pima County permitRight of WayROW/RUOT - — 7900 N LA CANADA DRIssued
2000-01-21P00RW00157Pima County permitRight of WayROW/RGAS - — 7900 N LA CANADA DR - REVISED 1/25/2000Issued
1999-10-19P99CP10739Pima County permitHistoricalCOMBO/COTH -Expired
1999-03-02P99CP02263Pima County permitHistoricalPLUMB/COTH -Expired
1998-09-16P98CP09172Pima County permitHistoricalCOMBO/COTH - — THE BRIDGE AT MOUNTAIN VIEWExpired
1998-09-16finaledP98CP09171Pima County permitHistoricalCOMBO/AOTH - — THE BRIDGE AT MOUNTAIN VIEWC of O
1998-09-16finaledP98CP09169Pima County permitHistoricalCOMBO/AOTH - — THE BRIDGE AT MOUNTAIN VIEWC of O
1998-08-31finaledP98CP08631Pima County permitHistoricalCOMBO/COTH - — THE BRIDGE AT MOUNTAIN VIEWC of O

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Record numbers link to the issuing office’s official file — Pima County’s portal for county permits, the City of Tucson’s for city records. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 22549073P — 22 permits on file from 1998 to 2025 (14 historical, 3 addition / alteration, 2 right of way, 1 building) — assembled from the Pima County parcel file, the City of Tucson GIS layers, and Pima County’s Accela permit portal (searched by parcel and by address, because the county’s parcel links break on older records). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.