Property overview — 3990 W Linda Vista Bl
3990 W Linda Vista Bl
- Electrical service: county permits weren’t checked for this address.
- Watch for: built 2000; gear this age is due for infrared scanning and torque checks.
- Other work on record: not checked.
From the Pima County Assessor; county permits weren’t checked. Record checked 13 Nov 2026. Not an inspection.
The permanent link and the summary above, sent once. No list.One email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list.
Is it time to upgrade?
Can’t tell yet: county permits weren’t checked for this address.
- Electrical service & distributionNot checkedCounty permits weren’t checked for this address. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalNot checkedPackaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyNot checkedAny alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofNot checkedThe assessor records the roof as Composition Shingle. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
What that usually means electrically
- Era-based check
Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear.
Solar and energy potential
- Roof footprint
- ≈ 2,385 sq ft (county building-footprint layer)
- Usable for solar, planning estimate
- ≈ 1,700 sq ft (~70% after setbacks, rooftop equipment and access paths)
- Array that could fit
- on the order of 20 kW — roughly 50 panels (low-tilt ballasted rows, 400 W class modules)
- Estimated annual production
- ≈ 33,000 kWh (PVWatts, Tucson sun, low-tilt south)
- Energy-charge offset, priced at TEP commercial rates
- Estimate $2,500–$4,500 a year (8–13¢/kWh; if Trico serves this meter, its rates differ)
The offset assumes the building uses the power as it is generated; surplus sent to the grid earns far less — TEP’s export rate is about 5¢/kWh, and Trico Electric Cooperative sets its own for members, so the load profile decides the real value. The 30% federal credit (§48E) still applies to commercial systems placed in service by the end of 2027 — projects that began construction by July 4, 2026 have longer; confirm timing with a tax adviser.
TEP grid capacityThis parcel is not inside any of the 11 areas TEP has mapped as saturated with distributed generation (the nearest, “Ina Rd and Thornydale Rd”, is about 1.8 miles away — TEP’s map set, July 2020). New generation still goes through TEP’s interconnection screens, and a heavy new load still merits a utility capacity check — the maps only mark where that review is most likely to bite.
Flood and drainage
The federal flood map and the local one are not the same map, and they do not always agree. FEMA’s is the insurance map; Pima County Regional Flood Control District regulates against its own, and that is the one a permit here is judged against.
- FEMA: we did not read the federal flood map for this snapshot. Check FEMA’s flood map for this address ↗
- Local floodplain (Pima County Regional Flood Control District): local floodplain mapping is not reproduced here. A property can sit outside FEMA’s zone and still be inside a locally regulated floodplain, floodway, sheet-flooding area or erosion hazard setback, so check the authority’s own map before planning work. Pima County RFCD flood hazard map for parcel 224462680 ↗ · Pima County Regional Flood Control District ↗
The record behind this read
- Parcel
- 224462680
- Year constructed
- 2000 (assessor record)
- Permitting authority
- Unincorporated Pima County
- Zoning
- CR-5
- Property type
- Misc Commercial
- Building area
- 2,337 sq ft
- Heating
- Heat Pump
- Electrical service
- County permits weren’t checked for this address. (the era estimate is from the year built, 2000 — not a measurement)
Building area and heating come from the Pima County Assessor’s file published 28 Jan 2026. Check any row against Pima County’s own parcel record ↗.
County permits weren’t checked for this address. Unincorporated Pima County issues its own building permits through Pima County Development Services; this report reads the City of Tucson’s file only. A records request to the county is the authoritative check.
See an error? Report a correction · About this data.
Utility and upgrade pathElectric service out here is split: Trico Electric Cooperative serves much of unincorporated Pima County, Tucson Electric Power serves the rest, and a few areas sit on other systems. The meter release, clearances and point of attachment for an upgrade come from whichever utility serves the meter — check a recent bill or the meter label. See TEP new-service requirements for the TEP side.
In the public record: All commercial property · Commercial property in 85742 · Commercial & industrial reports · Homes in 85742 · Permit data by neighborhood
Planning work at this property?
Arizona Electrical Solutions — electrical, HVAC, underground, design-build and general contracting in Tucson (four Arizona ROC licenses). The address, parcel and this report travel with your request.
Want a plain-English brief of this record first?
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Permanent link: Electrical permit history for 3990 W Linda Vista Bl (aztucsonelectricalsolutions.com/property/224462680/3990-w-linda-vista-bl-tucson-az-85742)
Electrical summary — 3990 W Linda Vista Bl, Tucson, AZ 85742
Parcel 224462680Year built 2000Building area 2,337 sq ftPermit history Not checked (Pima County issues permits here)Record checked 13 Nov 2026
- Electrical service: county permits weren’t checked for this address.
- Watch for: built 2000; gear this age is due for infrared scanning and torque checks.
- Other work on record: not checked.
Permits on record, newest first
County permits weren’t checked for this address.
Era flags
- Built 2000: gear this age is due for infrared scanning and torque checks.
Ask your inspector or engineer to check
- The main switchboard’s nameplate rating and the age and make of the distribution gear.
- Whether the arc-flash labels match the installed gear (NFPA 70E reviews them every five years).
Live report: https://www.aztucsonelectricalsolutions.com/property/224462680/3990-w-linda-vista-bl-tucson-az-85742
How this property compares nearby
Properties on W LINDA VISTA BL hold 1 City permit on record, 1 of them since 2022.
Counts and years from the same public records.
How this report was built
This is a reading of public records for parcel 224462680 — no City of Tucson permits on file — assembled from the Pima County parcel file and the City of Tucson’s published permit layers together with the City’s own migrated permit archive. City of Tucson permit records go back to the mid-1990s, with fewer before 2006, when the City’s older paper files were only partly digitized. County permits weren’t checked for this address — unincorporated Pima County issues its own through Pima County Development Services. The construction year, living area, heating, roof and walls on this page come from our saved copy of the Assessor’s own published data file (dated 28 Jan 2026). The sewer connection file and the flood map were not read for this snapshot. A permit that is absent here may predate the digitized record or sit in a system this snapshot did not read. This record was built 22 Aug 2026 and compared against the City’s 13 Nov 2026 permit export, with no change for this parcel.
What this report is and is not. This is a screening report written by Arizona Electrical Solutions from public records — the year the building went up, how it is classified and what has been permitted. It is not an inspection, an appraisal, a floodplain determination, or engineering, legal or purchasing advice, and nothing in it confirms what is installed at this address: a permit shows what was permitted, a missing permit does not mean nothing was done, and era notes describe what was common when the building went up, not what is in this one. Price figures are estimates, not quotes. The issuing agency’s own record is the official one and controls over anything summarized here — every permit links to it. Only someone looking at the panel can confirm the service size, the panel brand or the wiring.
Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.
Permit history: City of Tucson addresses, back to the mid-1990s. Elsewhere in Pima County: property facts from the Assessor, no permit history yet.