Electrical permit history — 2740 S Kinney Rd

2740 S Kinney Rd, Tucson — built 1966, with 32 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

2740 S Kinney Rd

Built 1966 — 1960s commercial stock · 32 permits on record; no permitted panel/service or HVAC work among them

Parcel
21229011A
Built
1966 (assessor record)
Jurisdiction
Unincorporated Pima County
Zoning
CB-1
Assessor use
Retail Strip Center
Parcel size
1.94 acres
Building area
9,953 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)

See the property

County aerial photograph centered on 2740 S Kinney Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2022 addition / alteration permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2022 addition / alteration permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. This parcel is in unincorporated Pima County, so we read the county’s own permit system — including its historical permits, which reach back into the 1990s where they exist. Every record links to the county’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Recorded sales (2)

Recorded transfers from the Pima County Assessor — 2 of 2
DatePriceType
2004-04-30$460,000Special Warranty Deed
2004-03-01$460,000Special Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2022-10-04 (P22RW01568) — KINNEY - W Naomi Rd.

Permit history (32)

Permit history for this parcel — 8 of 32 records
DateRecordWhatStatusValue
2022-10-04finaledP22RW01568Pima County permitRight of WayKINNEY - W Naomi RdFinal
2022-08-25P22FC00967Pima County permitAddition / alterationCommercial Building AlterationWithdrawn
2022-08-23finaledP22BP09996Pima County permitAddition / alterationMulti-family Building AlterationC of O
2022-08-23finaledP22BP09995Pima County permitAddition / alterationMultifamily residence alterationC of O
2022-07-14P22RW01102Pima County permitRight of WayKINNEY - w naomi rdApproved
2012-10-01P12RW01749Pima County permitRight of WayROW/RGAS - — 2740 S KINNEY RDIssued
2007-05-04P07CP04331Pima County permitHistoricalSIGN/SIGN - — KINNEY RD RETAIL CENTER (D/P 29/49)Application Expired
2007-04-17finaledP07CP03667Pima County permitHistoricalCOMBO/COTH - — KINNEY ROAD RETAIL CENTER DP 29/49Final
Show 24 older records
Permit history for this parcel — remaining 24 records
DateRecordWhatStatusValue
2007-04-16P07CP03630Pima County permitHistoricalELECT/COTH -Withdrawn
2007-03-01finaledP07CP01923Pima County permitC of O HistoricalC-OF-O/COTH - — KINNEY ROAD RETAIL CENTER REV 2 DP 29/49C of O
2007-03-01P07CP01922Pima County permitHistoricalCOMBO/SOTH -Withdrawn
2007-02-22finaledP07CP01705Pima County permitC of O HistoricalC-OF-O/COTH - — KINNEY RD RETAIL CNTR (DP 29/49)C of O
2007-02-07finaledP07CP01183Pima County permitC of O HistoricalC-OF-O/COTH - — KINNEY RD RETAIL CNTR (D/P 29/49)C of O
2006-11-27finaledP06CP13315Pima County permitHistoricalCOMBO/BVIO - — DP 29/49Final
2006-11-27finaledP06CP13313Pima County permitHistoricalCOMBO/BVIO - — DP 29/49 KINNEY ROAD RETAIL CENTERFinal
2006-11-27finaledP06CP13312Pima County permitHistoricalCOMBO/BVIO - — DP 29/49 KINNEY ROAD RETAIL CENTERFinal
2006-10-03P06RW02322Pima County permitRight of WayROW/RWAT - — 2740 S KINNEY RDIssued
2006-08-30finaledP06CP10364Pima County permitHistoricalELECT/SOTH -Final
2006-05-22P06CP06349Pima County permitC of O HistoricalC-OF-O/BVIO - — DP 29/49 KINNEY RD RETAIL CENTERApplication Expired
2006-05-16P06CP06094Pima County permitC of O HistoricalC-OF-O/BVIO -Application Expired
2006-05-16P06CP06095Pima County permitSepticSEPTIC/COTH -DA Issued
2006-01-18P06CP00595Pima County permitSepticSEPTIC/COTH - — DP 29/49 KINNEY ROAD RETAIL CENTERDA Issued
2005-12-21P05CP15046Pima County permitHistoricalSIGN/SIGN - — KINNEY RD RETAIL (D/P 29/49)Application Expired
2005-12-09finaledP05CP14617Pima County permitC of O HistoricalC-OF-O/COTH - — KINNEY RD RETAIL CNTR BLDG 4 (D/P 29/49C of O
2005-05-06finaledP05CP05327Pima County permitHistoricalCOMBO/CALT - — D/P 20/01Final
2005-05-06finaledP05CP05328Pima County permitHistoricalCOMBO/CALT - — D/P 20/01Final
2005-05-06finaledP05CP05329Pima County permitHistoricalCOMBO/CALT - — D/P 20/01Final
2005-02-22finaledP05CP02139Pima County permitHistoricalELECT/COTH -Final
2004-11-24finaledP04CP12991Pima County permitHistoricalCOMBO/CADD -Final
2004-10-06finaledP04CP11212Pima County permitHistoricalELECT/CADD - — D/P 20/01Final
2004-09-20P04CP10527Pima County permitHistoricalCOMBO/CALT - — DP 20/01 BLDG 4Application Expired
2004-09-20P04CP10529Pima County permitHistoricalCOMBO/CALT - — DP 20/01 BLDG 2Application Expired

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Showing the 32 most recent county records — this parcel has more. The full set is on Pima County’s permit portal (search the parcel number).

Record numbers link to the issuing office’s official file — Pima County’s portal for county permits, the City of Tucson’s for city records. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 21229011A — 32 permits on file from 2004 to 2022 (17 historical, 6 c of o historical, 4 right of way, 3 addition / alteration) — assembled from the Pima County parcel file, the City of Tucson GIS layers, and Pima County’s Accela permit portal (searched by parcel and by address, because the county’s parcel links break on older records). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.