Electrical permit history — 5785 S Belvedere Av

5785 S Belvedere Av, Tucson — built 2006, with 24 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

5785 S Belvedere Av

Build year not published — permits on file from 2006 · 24 permits on record; no permitted panel/service or HVAC work among them

Parcel
14034309A
Built
2006 (earliest permit on file)
Jurisdiction
Unincorporated Pima County
Zoning
CI-1
Assessor use
Warehouse W/Off/Rtl Interior @ .26-.60
Parcel size
2.44 acres
Sewer
Connection on file (2009, 2017, 2018) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)

See the property

County aerial photograph centered on 5785 S Belvedere Av, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2017 addition / alteration permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2017 addition / alteration permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. This parcel is in unincorporated Pima County, so we read the county’s own permit system — including its historical permits, which reach back into the 1990s where they exist. Every record links to the county’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Industrial and warehouse space usually means three-phase motor loads. High-bay LED retrofits and added VFDs both change the load picture.

Most recent permit on record for this parcel: 2018-11-01 (P18RW01859) — Gateway Phase 2 - Richard St Aubin.

Permit history (24)

Permit history for this parcel — 8 of 24 records
DateRecordWhatStatusValue
2018-11-01finaledP18RW01859Pima County permitRight of WayGateway Phase 2 - Richard St AubinFinal
2018-10-22P17BP05076-02Pima County permitAddition / alterationCommercial Building Addition - RevisionApproved
2018-07-24finaledP18RW01276Pima County permitRight of WayTricon Contracting - Megan DavisFinal
2018-05-01finaledP18BP03211Pima County permitElectrical / mechanicalMechanical/Plumbing EquipmentFinal
2018-04-18finaledP18BP02801Pima County permitElectrical / mechanicalMechanical/Plumbing EquipmentFinal
2018-01-26finaledP18RW00183Pima County permitRight of WaySOUTHWEST GAS, KRISTINE SCHWARTZ, BELVEDERE AVEFinal
2017-11-09finaledP17RW01751Pima County permitRight of WaySOUTHWEST GAS, SHAWN STONER, BELVEDEREFinal
2017-11-06P17BP05076-01Pima County permitAddition / alterationCommercial Building Addition - RevisionApproved
Show 16 older records
Permit history for this parcel — remaining 16 records
DateRecordWhatStatusValue
2017-08-16finaledP17BP05076Pima County permitAddition / alterationCommercial Building AdditionC of O
2017-05-11finaledP17RW00847Pima County permitRight of WayCOX COMMUNICAITONS - BELVEDERE AVE - CONNIE PAPPASFinal
2015-10-06finaledP15RW01545Pima County permitRight of WayROW / RTEL / CENTURYLINK - LINDA JOHNSONFinal
2015-01-16finaledP15CP00348Pima County permitBuildingCOMBO/COTH -Final
2013-08-15P13RW01321Pima County permitRight of WayROW/RDRI - — 5785 S BELVEDEREClosed
2013-04-30finaledP13CP02536Pima County permitOther StructuresCOMBO/SIGN - — DP 30/52Final
2013-04-01finaledP13CP01891Pima County permitOther StructuresCOMBO/FNCE -Final
2013-01-31P13CP00569Pima County permitElectrical / mechanicalCOMBO/MECH -Void
2012-11-19P12CP06787Pima County permitBuildingCOMBO/COTH - — P1205-037Void
2008-10-21P08RW01908Pima County permitRight of WayROW/RDRI - — 5785 S BELVEDERE AVIssued
2007-10-03finaledP07CP09188Pima County permitDamage/DemoDEMO/CDMO -Final
2007-09-19P07RW01844Pima County permitRight of WayROW/RSEW - — 5785 S BELVEDERE AVIssued
2007-06-15finaledP07CP05832Pima County permitHistoricalSIGN/SIGN -Final
2007-04-03P07RW00658Pima County permitRight of WayROW/RELE - — 5785 S BELVEDERE AVIssued
2006-08-15P06CP09790Pima County permitHistoricalZONING/COTH - — COUNTY ID # 6Withdrawn
2006-05-09finaledP06CP05768Pima County permitHistoricalCOMBO/CNEW - — DP 30/52 P1205-037C of O

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Record numbers link to the issuing office’s official file — Pima County’s portal for county permits, the City of Tucson’s for city records. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 14034309A — 24 permits on file from 2006 to 2018 (10 right of way, 3 addition / alteration, 3 electrical / mechanical, 3 historical) — assembled from the Pima County parcel file, the City of Tucson GIS layers, and Pima County’s Accela permit portal (searched by parcel and by address, because the county’s parcel links break on older records). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.