Electrical permit history — 5200 S Westover Av

5200 S Westover Av, Tucson — built 1974, with 29 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

5200 S Westover Av

Built 1974 — 1970s commercial stock · 29 permits on record; no permitted panel/service or HVAC work among them

Parcel
13712058A
Built
1974 (assessor record)
Jurisdiction
Unincorporated Pima County
Zoning
SH
Assessor use
County Park/Recreational Properties
Parcel size
34.82 acres
Building area
2,404 sq ft (assessor record)
Sewer
Connection on file (1998, 2005, 2022) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)

See the property

County aerial photograph centered on 5200 S Westover Av, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. This parcel is in unincorporated Pima County, so we read the county’s own permit system — including its historical permits, which reach back into the 1990s where they exist. Every record links to the county’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    A pool or spa was permitted in 1997. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

Most recent permit on record for this parcel: 2026-08-05 (P26BP05218).

Permit history (29)

Permit history for this parcel — 8 of 29 records
DateRecordWhatStatusValue
2026-08-05P26BP05218Pima County permitDamage/DemoWithdrawn
2026-02-11P26FC00077Pima County permitFloodplain UseCOBIssued
2026-02-09P26BP00853Pima County permitBuildingCommercial Building New — new ramadaIssued
2024-09-05finaledP24RW01202Pima County permitRight of WayWESTOVER - Nebraska and WestoverFinal
2023-10-01finaledP23RW01460Pima County permitRight of WayWESTOVER - Westover and NebraskaFinal
2023-09-11P22BP07819-01Pima County permitAddition / alterationCommercial Building Addition - RevisionApproved
2023-05-16finaledP23RW00633Pima County permitRight of WayWESTOVER - Westover and NebraskaFinal
2022-07-01P22BP07820Pima County permitAddition / alterationCommercial Building AdditionWithdrawn
Show 21 older records
Permit history for this parcel — remaining 21 records
DateRecordWhatStatusValue
2022-07-01P22BP07819Pima County permitAddition / alterationCommercial Building AdditionPermit Expired
2022-07-01P22BP07818Pima County permitBuildingCommercial Building OtherPermit Expired
2018-02-06P18HD00032Pima County permitCHFS – Health ReviewManzanita Park Splash PadApproved
2017-11-27finaledP17RW01805Pima County permitRight of WayCITY OF TUCSON WATER, MONICA GALLEGOS, WESTOVER AVFinal
2017-05-09finaledP17RW00831Pima County permitRight of WayCITY OF TUCSON WATER - WESTOVER AVE - LINDA DICKERSONFinal
2014-06-27P14CP04013Pima County permitBuildingCOMBO/CTI - — PIMA COUNTYExpired - Permit
2011-05-17finaledP11CP03206Pima County permitBuildingCOMBO/COTH -Final
2010-12-02finaledP10CP07210Pima County permitBuildingCOMBO/COTH - — 5200 South Westover Ave.Final
2004-02-27P04CP02382Pima County permitHistoricalCOMBO/COTH -Expired
2000-11-21P00CP11957Pima County permitHistoricalCOMBO/COTH - — MANZANITA PARKApplication Expired
2000-10-30P00CP11094Pima County permitHistoricalCOMBO/CADD -Expired
1998-07-28P98CP07426Pima County permitHistoricalPLUMB/COTH -Application Expired
1998-03-18P98RW00665Pima County permitRight of WayROW/RUOT - — 5200 S WESTOVER AV (WORK ON IRVINGTON RDIssued
1998-02-13P98RW00382Pima County permitRight of WayROW/RWAT - — 5200 S WESTOVER AV (CUT AT 5100 S SAN JOIssued
1998-02-03P98RW00301Pima County permitRight of WayROW/RUOT - — 5200 S WESTOVER AV (WORK ON IRVINGTON RDIssued
1998-01-30P98RW00269Pima County permitRight of WayROW/RELE - — 5200 S WESTOVER AV (MANZANITA PARK COMMUIssued
1997-09-12finaledP97CP10789Pima County permitHistoricalCOMBO/CNEW -C of O
1997-09-08finaledP97CP10616Pima County permitPool / spaPOOL/SPA/PCOM - — MANZANITA PARKFinal
1997-04-10finaledP97CP04056Pima County permitHistoricalCOMBO/CALT - — MANZANITA PARKFinal
1994-05-03finaled84844Pima County permitHistoricalPMSHIST/ -Final
1993-12-23finaled79778Pima County permitHistoricalPMSHIST/ -Final

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Showing the 29 most recent county records — this parcel has more. The full set is on Pima County’s permit portal (search the parcel number).

Record numbers link to the issuing office’s official file — Pima County’s portal for county permits, the City of Tucson’s for city records. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 13712058A — 29 permits on file from 1993 to 2026 (9 right of way, 8 historical, 5 building, 3 addition / alteration) — assembled from the Pima County parcel file, the City of Tucson GIS layers, and Pima County’s Accela permit portal (searched by parcel and by address, because the county’s parcel links break on older records). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.