3900 N Bear Canyon Rd, Tucson — built 1974, with 22 permits on record. Review electrical, HVAC and remodel history with links to official records.
Commercial property
3900 N Bear Canyon Rd
Built 1974 — 1970s commercial stock · 22 permits on record; no permitted panel/service or HVAC work among them
Permanent link: Electrical permit history for 3900 N Bear Canyon Rd (aztucsonelectricalsolutions.com/property/114274460/3900-n-bear-canyon-rd-tucson-az-85749) · Public records last checked 2026-08-16
- Parcel
- 114274460
- Built
- 1974 (assessor record)
- Jurisdiction
- Unincorporated Pima County
- Zoning
- SR
- Assessor use
- State School Prop
- Parcel size
- 9.76 acres
- Building area
- 40,782 sq ft (assessor record)
- Sewer
- Connection on file (1973) (county sewer connection records)
- Flood zone
- X — minimal flood hazard (FEMA)
See the property
Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.
Is it time to upgrade?
- Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
- Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
- Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
- RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.
A found permit means a lot. A missing one means less. This parcel is in unincorporated Pima County, so we read the county’s own permit system — including its historical permits, which reach back into the 1990s where they exist. Every record links to the county’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.
What that usually means electrically
- Era-based check — high priority
Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.
- Era-based check
NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.
Most recent permit on record for this parcel: 2023-08-21 (P23RW01158) — BEAR CANYON - PRINCE ROAD AND CAMINO SECO.
Permit history (22)
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 2023-08-21finaled | P23RW01158Pima County permit | Right of WayBEAR CANYON - PRINCE ROAD AND CAMINO SECO | Final | |
| 2015-01-29finaled | P15CP00652Pima County permit | Electrical / mechanicalCOMBO/ELEC - | Final | |
| 2007-10-19 | P07CP09694Pima County permit | HistoricalCOMBO/COTH - | Expired | |
| 2003-03-24 | P03IM01726Pima County permit | HistoricalIMAGES/ - | Submitted | |
| 2003-03-05 | P03RW00716Pima County permit | Right of WayROW/RGAS - — 3900 N BEAR CANYON RD | Issued | |
| 1997-08-11 | P97CP09559Pima County permit | Right of WayROW/RCAT - — 3900 N BEAR CANYON RD | Issued | |
| 1997-06-11 | P97CP06984Pima County permit | Right of WayROW/RWAT - — 3900 N BEAR CANYON RD | Issued | |
| 1997-04-08 | P97CP03971Pima County permit | Right of WayROW/RTEL - — 16095 N LAGO DEL ORO PW | Issued |
Show 14 older records
| Date | Record | What | Status | Value |
|---|---|---|---|---|
| 1997-04-08 | P97CP03970Pima County permit | Right of WayROW/RTEL - — SINAGUA RD & SANDARIO RD | Issued | |
| 1997-03-27 | P97CP03388Pima County permit | Right of WayROW/RTEL - — LIMEWOOD DR | Issued | |
| 1997-03-27 | P97CP03387Pima County permit | Right of WayROW/RTEL - — 7175 W CALLE SIETE | Issued | |
| 1997-03-21 | P97CP03090Pima County permit | Right of WayROW/RTEL - — 3400 E STALLION LN | Issued | |
| 1997-03-07 | P97CP02350Pima County permit | Right of WayROW/RTEL - — 5600 N VIA ELENA | Issued | |
| 1997-03-07 | P97CP02351Pima County permit | Right of WayROW/RTEL - — BOPP RD/SAN JOAQUIN RD | Issued | |
| 1997-02-24 | P97CP01781Pima County permit | Right of WayROW/RTEL - — MOUNTAIN SIDE DR & CAMINO DE OESTE | Issued | |
| 1997-02-24 | P97CP01780Pima County permit | Right of WayROW/RTEL - — 12310 W MANVILLE RD | Issued | |
| 1997-02-24 | P97CP01779Pima County permit | Right of WayROW/RTEL - — 6090 W PEREGRINE WY | Issued | |
| 1997-02-11 | P97CP01114Pima County permit | Right of WayROW/RTEL - — EL CAMINO DEL CERRO | Issued | |
| 1997-02-10 | P97CP01096Pima County permit | Right of WayROW/RTEL - — 1553 N SANDARIO RD | Issued | |
| 1997-02-05 | P97CP00866Pima County permit | Right of WayROW/RTEL - — 3775 W MORGAN (GORET RD / LLOYD BUSH DR) | Issued | |
| 1996-12-24 | P96CP01167Pima County permit | Right of WayROW/RTEL - — 3900 N BEAR CANYON RD | Issued | |
| 1996-12-11finaled | 119522Pima County permit | HistoricalPMSHIST/ - | Final |
How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.
Record numbers link to the issuing office’s official file — Pima County’s portal for county permits, the City of Tucson’s for city records. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.
This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.
Planning work at this property?
Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.
The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.
Send: the permanent link and the summary above, once. Watch: one email when a new permit, inspection result or code case appears on this parcel — nothing else, and you can stop any time. No list either way.
How this report was built
This is a reading of public records for parcel 114274460 — 22 permits on file from 1996 to 2023 (18 right of way, 3 historical, 1 electrical / mechanical) — assembled from the Pima County parcel file, the City of Tucson GIS layers, and Pima County’s Accela permit portal (searched by parcel and by address, because the county’s parcel links break on older records). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.
The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).
Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.