Electrical permit history — 6875 E Sunrise Dr

6875 E Sunrise Dr, Tucson — built 1999, with 30 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

6875 E Sunrise Dr

Built 1999 — 1990s commercial stock · 30 permits on record; no permitted panel/service or HVAC work among them

Parcel
11404705E
Built
1999 (assessor record)
Jurisdiction
Unincorporated Pima County
Zoning
CB-1
Assessor use
Retail Strip Center
Parcel size
0.72 acres
Building area
6,023 sq ft (assessor record)
Sewer
Connection on file (1999, 2002, 2011) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)

See the property

County aerial photograph centered on 6875 E Sunrise Dr, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. This parcel is in unincorporated Pima County, so we read the county’s own permit system — including its historical permits, which reach back into the 1990s where they exist. Every record links to the county’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    There is an electrical reconnect permit from 2022. The service was disconnected at some point and brought back — usually after a vacancy, a utility disconnect, or work that required the power off. Worth knowing what prompted it.

Most recent permit on record for this parcel: 2022-06-29 (P22BP07704) — Sign.

Permit history (30)

Permit history for this parcel — 8 of 30 records
DateRecordWhatStatusValue
2022-06-29P22BP07704Pima County permitOther StructuresSignPermit Expired
2022-04-27finaledP22BP04865Pima County permitElectrical / mechanicalElectrical ReconnectFinal
2019-12-09finaledP19BP07898Pima County permitElectrical / mechanicalElectrical ReconnectFinal
2019-09-16P19BP04566-01Pima County permitRevisionTenant Improvement - RevisionWithdrawn
2019-07-24P19BP04604Pima County permitElectrical / mechanicalElectrical ReconnectApplication Expired
2019-07-23P19BP04566Pima County permitBuildingTenant ImprovementExpired
2019-07-17P19BP04438Pima County permitElectrical / mechanicalVoid
2014-11-20P14CP07230Pima County permitOther StructuresCOMBO/SIGN -Application Expired
Show 22 older records
Permit history for this parcel — remaining 22 records
DateRecordWhatStatusValue
2014-04-15finaledP14CP02297Pima County permitBuildingCOMBO/CALT -C of O
2012-12-17finaledP12CP07294Pima County permitElectrical / mechanicalCOMBO/ELEC -Final
2011-03-02finaledP11CP01455Pima County permitOther StructuresCOMBO/SIGN - — DP 14/74Final
2010-11-12finaledP10CP06848Pima County permitBuildingCOMBO/CTI - — DP13060, DP14074C of O
2010-11-12P10HD00255Pima County permitCHFS – Health ReviewHEALTH/FFE -Approved
2009-08-03finaledP09CP04521Pima County permitC of O HistoricalCOMBO/COFO - — SUNRISE/KOLB COMMERCIAL CENTER 14074C of O
2007-11-14P07CP10384Pima County permitC of O HistoricalC-OF-O/COTH -Application Expired
2007-10-31finaledP07CP09998Pima County permitHistoricalSIGN/SIGN - — DP 14/74Final
2006-02-13P06CP01719Pima County permitHistoricalSIGN/SIGN - — SUNRISE/KOLB COMMERCIAL CNTR (D/P 14/74Expired
2004-05-17finaledP04CP05651Pima County permitC of O HistoricalC-OF-O/COTH - — SUNRISE/KOLB COMMERCIAL CNTR (D/P 14/74C of O
2004-05-04finaledP04CP05121Pima County permitHistoricalSIGN/SIGN - — KOLB/SUNRISE COMMERCIAL(D/P 14/74)Final
2002-09-03P02CP08950Pima County permitHistoricalSIGN/SIGN -Application Expired
2002-05-07P02CP04746Pima County permitHistoricalSIGN/SIGN - — DP 14/74 SUNRISE/KOLB COMMERCIAL #111Expired
2002-04-09finaledP02CP03569Pima County permitHistoricalCOMBO/CTI - — SUNRISE/KOLB COMMERCIAL CENTER DP 14/74C of O
1999-09-20finaledP99CP09733Pima County permitHistoricalMECH/COTH -Final
1999-07-14P99CP07501Pima County permitC of O HistoricalC-OF-O/COTH -Withdrawn
1999-07-12finaledP99CP07378Pima County permitHistoricalCOMBO/CTI - — KOLB SUNRISE COMMERCIAL CENTERFinal
1999-07-08P99CP07304Pima County permitC of O HistoricalC-OF-O/COTH - — KOLB SUNRISE COMMERCIALWithdrawn
1999-07-02P99CP07150Pima County permitHistoricalSIGN/SIGN - — SUNRISE/KOLB COMMERCIAL CENTERApplication Expired
1999-04-30finaledP99CP04737Pima County permitHistoricalCOMBO/CTI - — SUNRISE/KOLB COMMERCIAL CENTERC of O
1999-04-15P99CP04116Pima County permitHistoricalSIGN/SIGN - — SUNRISE/KOLB COMMERCIAL CENTERApplication Expired
1998-04-28finaledP98CP04100Pima County permitHistoricalCOMBO/CNEW -Final

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Record numbers link to the issuing office’s official file — Pima County’s portal for county permits, the City of Tucson’s for city records. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 11404705E — 30 permits on file from 1998 to 2022 (12 historical, 5 electrical / mechanical, 5 c of o historical, 3 other structures) — assembled from the Pima County parcel file, the City of Tucson GIS layers, and Pima County’s Accela permit portal (searched by parcel and by address, because the county’s parcel links break on older records). Public records last checked 2026-08-17; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.