Electrical permit history — 5780 N Swan Rd

5780 N Swan Rd, Tucson — built 2021, with 30 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

5780 N Swan Rd

Build year not published — permits on file from 2021 · 30 permits on record; no permitted panel/service or HVAC work among them

Parcel
109300160
Built
2021 (earliest permit on file)
Jurisdiction
Unincorporated Pima County
Zoning
CB-1
Assessor use
Common Area Of Office Condominium
Parcel size
0.92 acres
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)

See the property

County aerial photograph centered on 5780 N Swan Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2024 building permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2024 building permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. This parcel is in unincorporated Pima County, so we read the county’s own permit system — including its historical permits, which reach back into the 1990s where they exist. Every record links to the county’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Routine

    Office and medical tenant improvements are usually limited by available panel spaces and branch circuit capacity, not by the service itself.

Most recent permit on record for this parcel: 2025-11-10 (P24BP08972-04) — Tenant Improvement - Revision.

Permit history (30)

Permit history for this parcel — 8 of 30 records
DateRecordWhatStatusValue
2025-11-10P24BP08972-04Pima County permitRevisionTenant Improvement - RevisionApproved
2025-08-05finaledP25BP05844Pima County permitElectrical / mechanicalElectrical Equipment — EV Charging at 5780 N. Swan RoadFinal
2025-08-04P24BP08972-03Pima County permitRevisionTenant Improvement - RevisionApproved
2025-08-04P25BP02953-01Pima County permitElectrical / mechanicalElectrical/Mechanical Equipment - RevisionApproved
2025-08-01P25BP05767Pima County permitAddition / alterationCommercial Building Alteration — 24184a EV Charging for 5780 N. SwanVoid
2025-06-03P24BP08972-02Pima County permitRevisionTenant Improvement - RevisionApproved
2025-05-14P25BP03809Pima County permitBuildingTenant ImprovementIssued
2025-04-11P25BP02953Pima County permitElectrical / mechanicalElectrical/Mechanical EquipmentIssued
Show 22 older records
Permit history for this parcel — remaining 22 records
DateRecordWhatStatusValue
2025-02-28P24BP08972-01Pima County permitRevisionTenant Improvement - RevisionApproved
2024-10-29finaledP24BP09434Pima County permitBuildingTenant ImprovementC of O
2024-10-22P24BP09239Pima County permitBuildingVoid
2024-10-11P24BP08972Pima County permitBuildingTenant ImprovementIssued
2024-07-19P24BP06737Pima County permitBuildingTenant ImprovementPermit Expired
2023-03-07P23RW00293Pima County permitRight of WaySWAN - Swan & SunriseRequest for Corrections
2022-12-05P22BP14025Pima County permitDamage/DemoPermit Expired
2022-11-01P22BP12896Pima County permitOther StructuresSignPermit Expired
2022-09-21P21BP04216-03Pima County permitAddition / alterationCommercial Building Alteration - RevisionWithdrawn
2022-08-02finaledP22BP09182Pima County permitBuildingCommercial Building OtherFinal
2022-07-13finaledP22RW01082Pima County permitRight of Wayswan - E. SUNRISE DRFinal
2022-04-29finaledP22BP05022Pima County permitBuildingTenant ImprovementC of O
2022-03-17P22BP02988Pima County permitAddition / alterationCommercial Building AlterationApplication Expired
2022-03-15finaledP22RW00434Pima County permitRight of Wayswan - E. SUNRISE DRFinal
2022-02-03P21BP05652-02Pima County permitRevisionTenant Improvement - RevisionApproved
2022-02-01finaledP22BP01175Pima County permitDamage/DemoFinal
2021-12-23P21BP04216-02Pima County permitAddition / alterationCommercial Building Alteration - RevisionApproved
2021-12-10P21BP05652-01Pima County permitRevisionTenant Improvement - RevisionApproved
2021-11-04P21BP04216-01Pima County permitAddition / alterationCommercial Building Alteration - RevisionApproved
2021-06-18finaledP21BP05652Pima County permitBuildingTenant ImprovementC of O
2021-05-10P21FC00430Pima County permitFloodplain UseCOBWithdrawn
2021-05-08finaledP21BP04216Pima County permitAddition / alterationCommercial Building AlterationFinal

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Showing the 30 most recent county records — this parcel has more. The full set is on Pima County’s permit portal (search the parcel number).

Record numbers link to the issuing office’s official file — Pima County’s portal for county permits, the City of Tucson’s for city records. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 109300160 — 30 permits on file from 2021 to 2025 (8 building, 6 revision, 6 addition / alteration, 3 electrical / mechanical) — assembled from the Pima County parcel file, the City of Tucson GIS layers, and Pima County’s Accela permit portal (searched by parcel and by address, because the county’s parcel links break on older records). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.