Electrical permit history — 4415 N Flowing Wells Rd

4415 N Flowing Wells Rd, Tucson — built 1972, with 20 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

4415 N Flowing Wells Rd

Built 1972 — 1970s commercial stock · 20 permits on record; no permitted panel/service or HVAC work among them

Parcel
10403231C
Built
1972 (assessor record)
Jurisdiction
Unincorporated Pima County
Zoning
MU
Assessor use
Restaurant Sit Down
Parcel size
0.57 acres
Building area
1,869 sq ft (assessor record)
Sewer
Connection on file (1972) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)

See the property

County aerial photograph centered on 4415 N Flowing Wells Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2019 addition / alteration permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2019 addition / alteration permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. This parcel is in unincorporated Pima County, so we read the county’s own permit system — including its historical permits, which reach back into the 1990s where they exist. Every record links to the county’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Food service carries heavy, cycling kitchen loads and exhaust interlocks. Capacity and existing panel space are the first things to verify on any remodel.

Recorded sales (2)

Recorded transfers from the Pima County Assessor — 2 of 2
DatePriceType
2017-10-31$315,000Warranty Deed
2016-10-07$215,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2026-07-22 (P26FC00540) — ADD, COB.

Permit history (20)

Permit history for this parcel — 8 of 20 records
DateRecordWhatStatusValue
2026-07-22P26FC00540Pima County permitFloodplain UseADD, COBRequest for Corrections
2026-07-21P26BP04900Pima County permitAddition / alterationCommercial Building Addition — Kitchen AdditionDeficient-Needs Flood Review
2023-12-15finaledP23BP11897Pima County permitBuildingCommercial Building NewFinal
2023-10-25P23RW01620Pima County permitRight of WayFLOWING WELLS - Flowing Wells Rd and Wet more RdRequest for Corrections
2023-08-10P23BP07172Pima County permitAddition / alterationCommercial Building AlterationApplication Expired
2021-06-10finaledP21BP05354Pima County permitElectrical / mechanicalElectrical EquipmentFinal
2020-10-02finaledP20BP06803Pima County permitElectrical / mechanicalElectrical EquipmentFinal
2019-10-11P19HD00246Pima County permitCHFS – Health ReviewEL NENEApproved
Show 12 older records
Permit history for this parcel — remaining 12 records
DateRecordWhatStatusValue
2019-10-09finaledP19BP06483Pima County permitAddition / alterationCommercial Building AdditionC of O
2019-10-09P19FC00626Pima County permitFloodplain UseADDIssued
2016-11-23P16HD00278Pima County permitCHFS – Health ReviewEl NeneApproved
2016-11-22finaledP16BP07129Pima County permitBuildingTenant ImprovementC of O
2016-11-22P16FC00611Pima County permitFloodplain UseADDIssued
2015-08-10finaledP15RW01239Pima County permitRight of WayROW / RSEW / KE & GFinal
2012-02-29finaledP12CP01186Pima County permitC of O HistoricalCOMBO/COFO -C of O
2008-07-03P08CP05092Pima County permitHistoricalSIGN/SIGN -Expired
2007-06-26finaledP07CP06298Pima County permitHistoricalELECT/COTH -Final
2007-06-21finaledP07CP06084Pima County permitHistoricalSIGN/SIGN -Final
2006-08-16P06CP09860Pima County permitHistoricalZONING/COTH - — COUNTY ID # 80Application Expired
2006-05-23P06RW01276Pima County permitRight of WayROW/RWAT - — 4415 N FLOWING WELLS RDIssued

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Record numbers link to the issuing office’s official file — Pima County’s portal for county permits, the City of Tucson’s for city records. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 10403231C — 20 permits on file from 2006 to 2026 (4 historical, 3 floodplain use, 3 addition / alteration, 3 right of way) — assembled from the Pima County parcel file, the City of Tucson GIS layers, and Pima County’s Accela permit portal (searched by parcel and by address, because the county’s parcel links break on older records). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.