Electrical permit history — 4110 W Sweetwater Dr

4110 W Sweetwater Dr, Tucson — built 1949, with 30 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

4110 W Sweetwater Dr

Built 1949 — 1940s commercial stock · 30 permits on record; no permitted panel/service or HVAC work among them

Parcel
10302014A
Built
1949 (assessor record)
Jurisdiction
Unincorporated Pima County
Zoning
SR
Assessor use
Nursing/ Orphanage/ Rehab For Profit
Parcel size
11.57 acres
Building area
42,512 sq ft (assessor record)
Sewer
No connection on file (sewer or septic status not confirmed by the record — verify on site)
Flood zone
X — minimal flood hazard (FEMA)

See the property

County aerial photograph centered on 4110 W Sweetwater Dr, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2024 addition / alteration permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2024 addition / alteration permit is on file (and 2 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. This parcel is in unincorporated Pima County, so we read the county’s own permit system — including its historical permits, which reach back into the 1990s where they exist. Every record links to the county’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

Recorded sales (1)

Recorded transfers from the Pima County Assessor — 1 of 1
DatePriceType
2018-02-15$7,608,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2025-12-17 (P25RR00209) — C of O reprint 4110 W Sweetwater.

Permit history (30)

Permit history for this parcel — 8 of 30 records
DateRecordWhatStatusValue
2025-12-17P25RR00209Pima County permitPublic Records RequestC of O reprint 4110 W SweetwaterIn Review
2024-04-26P24BP04190Pima County permitManufactured BuildingManufactured BuildingPermit Expired
2024-03-18P24SS00209Pima County permitSepticAlternative SepticVoid
2024-02-26finaledP24BP02062Pima County permitAddition / alterationCommercial Building AdditionC of O
2024-02-26finaledP24BP02060Pima County permitBuildingCommercial Building NewC of O
2024-01-22finaledP24BP00709Pima County permitAddition / alterationCommercial Building AlterationC of O
2023-12-20P23SC00060-01Pima County permitAddition / alterationCottonwood Tucson, 32 Bed Addition - RevisionApproved
2023-07-07finaledP23BP06053Pima County permitOther StructuresMinor Misc StructuresFinal
Show 22 older records
Permit history for this parcel — remaining 22 records
DateRecordWhatStatusValue
2023-06-30P23SS00406Pima County permitSepticAlternative SepticDA Issued
2023-06-06P23SS00344Pima County permitSepticConventional SepticDA Issued
2021-06-22P21CN00009Pima County permitConstruction NoiseIssued
2021-06-11P21CN00007Pima County permitConstruction NoiseIssued
2021-05-03P21SS00312Pima County permitSepticConventional SepticDA Issued
2021-02-18finaledP21BP01373Pima County permitDamage/DemoFinal
2021-01-15finaledP21RR00008Pima County permitPublic Records RequestSeptic Record RequestComplete
2018-11-19P18HD00297Pima County permitCHFS – Health ReviewCOTTONWOOD OF TUCSONWithdrawn
2017-11-28finaledP17RR00481Pima County permitPublic Records RequestZVL Old Republic 4110 W. SweetwaterComplete
2010-01-25finaledP10CP00450Pima County permitBuildingCOMBO/COTH -Final
2008-10-15P08HD00149Pima County permitCHFS – Health ReviewHEALTH/FFE -Approved
2008-10-15finaledP08CP07604Pima County permitHistoricalCOMBO/CTI - — DP 31/03 BLDG 9C of O
2007-11-19finaledP07CP10516Pima County permitHistoricalPLUMB/COTH -Final
2007-11-08finaledP07CP10259Pima County permitHistoricalCOMBO/COTH - — DP 31/03 P1205-062Final
2007-10-31P07CP09999Pima County permitHistoricalPLUMB/ -Application Expired
2007-03-19P07RW00567Pima County permitRight of WayROW/RDRI - — 4110 W SWEETWATER DRIssued
2006-09-06finaledP06CP10567Pima County permitHistoricalELECT/COTH - — COTTONWOOD DE TUCSON DP 28/01Final
2004-07-20finaledP04CP08310Pima County permitHistoricalCOMBO/SALT - — CORONA DE TUCSON BLDG 4 DP: 28001Final
2004-07-20finaledP04CP08311Pima County permitHistoricalCOMBO/SALT - — COTTONWOOD DE TUCSON BLDG 3 DP: 28001Final
2004-07-19P04CP08227Pima County permitHistoricalCOMBO/COTH - — COTTONWOOD DE TUCSON DP 25/95Application Expired
2004-04-13finaledP04CP04277Pima County permitDamage/DemoDEMO/RDMO - — COTTONWOOD DE TUCSON DP 25/95Final
2003-10-08P03RW02919Pima County permitRight of WayROW/RWAT - — 4110 W SWEETWATER DRIssued

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Showing the 30 most recent county records — this parcel has more. The full set is on Pima County’s permit portal (search the parcel number).

Record numbers link to the issuing office’s official file — Pima County’s portal for county permits, the City of Tucson’s for city records. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 10302014A — 30 permits on file from 2003 to 2025 (8 historical, 4 septic, 3 public records request, 3 addition / alteration) — assembled from the Pima County parcel file, the City of Tucson GIS layers, and Pima County’s Accela permit portal (searched by parcel and by address, because the county’s parcel links break on older records). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).