Electrical permit history — 5910 N Oracle Rd

5910 N Oracle Rd, Tucson — built 1973, with 36 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

5910 N Oracle Rd

Built 1973 — 1970s commercial stock · 36 permits on record; no permitted panel/service or HVAC work among them

Parcel
10221018A
Built
1973 (assessor record)
Jurisdiction
Unincorporated Pima County
Zoning
CB-1
Assessor use
Motel W/ Restaurant/Lounge Facilities
Parcel size
3.02 acres
Building area
36,783 sq ft (assessor record)
Sewer
Connection on file (1998, 2003) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)

See the property

County aerial photograph centered on 5910 N Oracle Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. This parcel is in unincorporated Pima County, so we read the county’s own permit system — including its historical permits, which reach back into the 1990s where they exist. Every record links to the county’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check — high priority

    Distribution gear this age is frequently past the point where the manufacturer still supports it. Breakers and fusible switches for obsolete lines can carry long lead times, which turns an outage into a shutdown. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Worth confirming

    Food service carries heavy, cycling kitchen loads and exhaust interlocks. Capacity and existing panel space are the first things to verify on any remodel.

  • Worth confirming

    A pool or spa was permitted in 2002. Pool equipment brings its own bonding grid, GFCI requirements, and usually a subpanel — and the bonding rules have tightened since, so older installations are worth verifying.

Recorded sales (1)

Recorded transfers from the Pima County Assessor — 1 of 1
DatePriceType
2000-05-05$2,100,000Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2021-04-30 (P21RW00874) — ORACLE - RUDASILL RD.

Permit history (36)

Permit history for this parcel — 8 of 36 records
DateRecordWhatStatusValue
2021-04-30P21RW00874Pima County permitRight of WayORACLE - RUDASILL RDWithdrawn
2017-01-13finaledP17RR00013Pima County permitPublic Records RequestC of O ReprintComplete
2016-12-02finaledP16RR00545Pima County permitPublic Records RequestZoning Verification LetterComplete
2016-10-28P16RR00494Pima County permitPublic Records RequestC of O ReprintIn Review
2016-09-16finaledP16RR00418Pima County permitPublic Records RequestC of O ReprintComplete
2016-06-08P16BP03672Pima County permitDamage/DemoPermit Expired
2013-07-11P13CP04332Pima County permitOther StructuresCOMBO/SIGN - — DP 27/08Expired
2011-02-08finaledP11CP00943Pima County permitBuildingCOMBO/CTI - — LA POSADA 27008 EB40047Final
Show 28 older records
Permit history for this parcel — remaining 28 records
DateRecordWhatStatusValue
2010-06-30P10CP04055Pima County permitOther StructuresCOMBO/COTH -Expired
2003-09-08finaledP03CP09581Pima County permitHistoricalMECH/COTH -Final
2003-06-25P03CP06712Pima County permitHistoricalSIGN/SIGN - — LA POSADA INN 5900 N ORACLE RDExpired
2003-03-10P03CP02353Pima County permitHistoricalSIGN/SIGN - — LA POSADA LODGE & CASITASExpired
2003-01-30finaledP03CP00944Pima County permitHistoricalCOMBO/CTI -C of O
2002-12-23P02CP12598Pima County permitHistoricalSIGN/SIGN - — LA POSADA RESORT & CASITAS, "MIGUEL'S"Expired
2002-10-16finaledP02CP10393Pima County permitHistoricalSIGN/SIGN - — LA POSADA LODGE (CLIFF MANOR INN)Final
2002-10-03finaledP02CP10013Pima County permitHistoricalCOMBO/CTI - — LA POSADA (CLIFF MANOR INN)C of O
2002-09-17finaledP02CP09423Pima County permitHistoricalCOMBO/CTI - — LA POSADA HOTEL & RESTAURANTC of O
2002-07-05finaledP02CP06887Pima County permitPool / spaPOOL/SPA/PSEM - — ORACLE FOOTHILLS ESTATES LOTS 11 - 15Final
2001-10-10P01CP09853Pima County permitC of O HistoricalC-OF-O/COTH -Application Expired
2001-07-31P01CP07581Pima County permitPool / spaPOOL/SPA/PSEM -Withdrawn
2001-06-25P01CP06228Pima County permitHistoricalCOMBO/CADD - — ORACLE FOOTHILLS ESTATES NO 1 LOT 11Expired
2001-06-25finaledP01CP06229Pima County permitHistoricalCOMBO/CALT - — ORACLE FOOTHILLS ESTATES NO 1 LOT 11Final
2001-05-03P01CP04400Pima County permitFence / wallWALL/FEN/WALL - — ORACLE FOOTHILLS ESTATES LOT 11-15Expired
2001-03-23finaledP01CP03001Pima County permitHistoricalCOMBO/CALT - — LA POSADA HOTEL (CLIFF MANOR INN)C of O
2000-11-13P00CP11598Pima County permitHistoricalELECT/COTH -Application Expired
2000-09-19finaledP00CP09541Pima County permitHistoricalCOMBO/CALT - — CLIFF MANOR INNFinal
2000-09-19finaledP00CP09538Pima County permitHistoricalPLUMB/COTH - — ORACLE FOOTHILLS ESTATES LOT 11Final
2000-09-18P00CP09509Pima County permitHistoricalPLUMB/SOTH - — ORACLE FOOTHILLS ESTATES #1 LOT11-15Expired
1998-07-21P98CP07171Pima County permitHistoricalSIGN/SIGN -Withdrawn
1997-02-14finaled119205Pima County permitHistoricalPMSHIST/ -C of O
1991-11-26finaled55884Pima County permitHistoricalPMSHIST/ -Final
1991-10-23finaled55022Pima County permitHistoricalPMSHIST/ -Final
1991-08-12finaled53225Pima County permitHistoricalPMSHIST/ -Final
1989-10-12finaled36333Pima County permitHistoricalPMSHIST/ -Final
1989-09-11finaled35401Pima County permitHistoricalPMSHIST/ -Final
1989-07-03finaled33532Pima County permitHistoricalPMSHIST/ -Final

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Showing the 36 most recent county records — this parcel has more. The full set is on Pima County’s permit portal (search the parcel number).

Record numbers link to the issuing office’s official file — Pima County’s portal for county permits, the City of Tucson’s for city records. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 10221018A — 36 permits on file from 1989 to 2021 (23 historical, 4 public records request, 2 other structures, 2 pool / spa) — assembled from the Pima County parcel file, the City of Tucson GIS layers, and Pima County’s Accela permit portal (searched by parcel and by address, because the county’s parcel links break on older records). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.