Electrical permit history — 2945 W Ina Rd

2945 W Ina Rd, Tucson — built 1995, with 33 permits on record. Review electrical, HVAC and remodel history with links to official records.

Commercial property

2945 W Ina Rd

Built 1995 — 1990s commercial stock · 33 permits on record; no permitted panel/service or HVAC work among them

Parcel
101046960
Built
1995 (assessor record)
Jurisdiction
Unincorporated Pima County
Zoning
TR
Assessor use
Medical Clinic
Parcel size
3.82 acres
Building area
45,153 sq ft (assessor record)
Sewer
Connection on file (1999, 2001, 2007) (county sewer connection records)
Flood zone
X — minimal flood hazard (FEMA)

See the property

County aerial photograph centered on 2945 W Ina Rd, parcel outlined

Pima County orthophoto (Pictometry 2024 / PAG 2023 / NAIP 2023 mosaic) — parcel outlined in yellow. Aerials can predate recent work and show nothing about what is inside; context, not evidence.

Is it time to upgrade?

  • Electrical service & distributionNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2022 building permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. That does not mean the gear is original — only that nothing has been permitted here recently. Where it matters is capacity: obsolete distribution lines carry breaker and fusible-switch lead times that turn an outage into a shutdown, and that is worth knowing before a new tenant or a new rooftop unit. Separately from replacement: NFPA 70E expects the arc-flash study to be reviewed at least every five years, or after any change to the service.
  • Heating, cooling & mechanicalNot in this windowNothing in the permit records we read for this parcel that names this system. Worth knowing: a 2022 building permit is on file (and 1 more like it) — work like this is often folded into a larger permit without being named, so open that record and check its scope before concluding anything. Packaged rooftop units work harder in Tucson than almost anywhere, so 12 to 15 years is a realistic service life rather than the 15 to 20 the industry quotes. Worth confirming from the equipment nameplate rather than the record. Replacing a rooftop unit is also an electrical question: the new unit's minimum circuit ampacity and its disconnect often differ from the old one.
  • Fire alarm & life safetyNot in this windowNothing in the permit records we read for this parcel that names this system. Any alarm or sprinkler work here predates this feed. For an occupied commercial building that is worth confirming from the panel and the inspection tags rather than assuming.
  • RoofNot in this windowNothing in the permit records we read for this parcel that names this system. Roof age matters electrically too: it sets what can be penetrated for new rooftop units, conduit, or solar.

A found permit means a lot. A missing one means less. This parcel is in unincorporated Pima County, so we read the county’s own permit system — including its historical permits, which reach back into the 1990s where they exist. Every record links to the county’s official file. A blank line does not say nothing was done: work gets done without permits all the time. The only way to know what is actually installed is to look at it.

What that usually means electrically

  • Era-based check

    Gear in this age range is usually still supported but is due for infrared scanning and torque verification if that has not been done recently. The permit record does not confirm this; an on-site inspection is required.

  • Era-based check

    NFPA 70E expects arc-flash studies to be reviewed at least every five years, or after any change to the service. Buildings this age often have labeling that no longer matches the installed gear. The permit record does not confirm this; an on-site inspection is required.

  • Routine

    Office and medical tenant improvements are usually limited by available panel spaces and branch circuit capacity, not by the service itself.

Recorded sales (1)

Recorded transfers from the Pima County Assessor — 1 of 1
DatePriceType
2004-11-04$4,208,100Special Warranty Deed

Recorded sales are the sales the Pima County Assessor has on file from affidavits of property value — not every transfer, not listings, and not a valuation. Parties are never shown here. A sale with no permitted electrical work since is worth knowing before the next sale or a remodel.

Most recent permit on record for this parcel: 2024-01-05 (P24BP00164) — Sign.

Permit history (33)

Permit history for this parcel — 8 of 33 records
DateRecordWhatStatusValue
2024-01-05finaledP24BP00164Pima County permitOther StructuresSignFinal
2024-01-04P24BP00154Pima County permitBuildingVoid
2023-08-29P22BP12363-02Pima County permitRevisionTenant Improvement - RevisionApproved
2023-06-08finaledP23RW00752Pima County permitRight of WayINA - N Shannon RdFinal
2023-05-19P23BP04515Pima County permitAddition / alterationCommercial Building AlterationPermit Expired
2023-04-25P22BP12363-01Pima County permitRevisionTenant Improvement - RevisionApproved
2022-10-18finaledP22BP12363Pima County permitBuildingTenant ImprovementC of O
2020-04-22P20BP02539Pima County permitOther StructuresSignApplication Expired
Show 25 older records
Permit history for this parcel — remaining 25 records
DateRecordWhatStatusValue
2020-02-06P19BP06090-02Pima County permitRevisionTenant Improvement - RevisionApproved
2020-01-23P19BP06090-01Pima County permitRevisionTenant Improvement - RevisionApproved
2019-09-25finaledP19BP06090Pima County permitBuildingTenant ImprovementC of O
2019-09-09finaledP19RW01673Pima County permitRight of WayINA - N Shannon RDFinal
2018-03-05finaledP18BP01509Pima County permitOther StructuresSignFinal
2014-07-17P14CP04420Pima County permitOther StructuresCOMBO/SIGN -Permit Expired
2014-06-12P14RW00830Pima County permitRight of WayROW/RCAT - — 2945 W INA RDClosed
2014-06-12P14RW00831Pima County permitRight of WayROW/RCAT - — 2945 W INA RDClosed
2013-06-26finaledP13CP04033Pima County permitBuildingCOMBO/CTI - — DP 01207 P1203--020C of O
2012-03-09finaledP12CP01420Pima County permitC of O HistoricalCOMBO/COFO -C of O
2011-05-05P11CP02927Pima County permitBuildingCOMBO/CTI - — 2945 W INA RD SUITE 101Expired
2008-04-18finaledP08CP02840Pima County permitHistoricalCOMBO/CTI - — DP 12/7C of O
2007-03-09P07RW00517Pima County permitRight of WayROW/RTEL - — 2945 W INA RDIssued
2007-01-23finaledP07CP00635Pima County permitHistoricalCOMBO/CTI - — DP 12/7 GROUP HEALTH MEDICAL ASSOCIATESC of O
2007-01-23finaledP07CP00634Pima County permitHistoricalCOMBO/CTI - — DP 12/07 GROUP HEALTH MEDICAL ASSOCIATESC of O
2006-12-22finaledP06CP14123Pima County permitHistoricalCOMBO/CTI - — GROUP HEALTH MEDICAL ASSOCIATES DP12/7C of O
2005-10-06finaledP05CP12019Pima County permitHistoricalCOMBO/CTI - — DP 12/7C of O
2005-06-30finaledP05CP07806Pima County permitHistoricalCOMBO/CTI - — GROUP HEALTH MEDICAL ASSOC. (D/P 12/07)C of O
2005-06-14finaledP05CP07081Pima County permitHistoricalCOMBO/CTI - — GROUP HEALTH MEDICAL DP: 12007C of O
2002-02-06P02CP01303Pima County permitHistoricalSIGN/SIGN -Application Expired
2001-03-08finaledP01CP02367Pima County permitHistoricalCOMBO/CTI - — DP 12/07C of O
2000-03-23P00CP03064Pima County permitHistoricalSIGN/SIGN -Expired
1999-04-22finaledP99CP04400Pima County permitHistoricalCOMBO/COTH - — GROUP HEALTH MEDICAL ASSOCIATESC of O
1998-05-18P98CP04722Pima County permitHistoricalSIGN/SIGN - — GROUP HEALTH MEDICAL ASSOCIATESExpired
1998-03-31finaledP98CP03021Pima County permitHistoricalCOMBO/CALT - — GROUP HEALTH MEDICAL ASSOCIATESC of O

How to read the status column: Final / Complete / C of O — city records show the permit was finalized. Issued — the work was permitted, but final completion is not confirmed. Applied / In review / Approved / Fees paid — proposed, not completion. Expired — the permit expired without a confirmed final status. Void / Withdrawn / Canceled — not evidence the work was installed. Any other status is shown exactly as the issuing office records it, without a completion reading.

Showing the 33 most recent county records — this parcel has more. The full set is on Pima County’s permit portal (search the parcel number).

Record numbers link to the issuing office’s official file — Pima County’s portal for county permits, the City of Tucson’s for city records. Highlighted rows are the ones that imply electrical work or an unpermitted-work finding.

This is an inference from public records — the year a structure was built, how it is classified, and what has been permitted. It is not an inspection, and nothing here confirms what is actually installed at this address. The only way to know is to look in the panel. See an error in this public-record report? Report a correction · About this data.

Planning work at this property?

Arizona Electrical Solutions provides electrical, HVAC, underground, design-build, tenant-improvement and general-contracting services in Tucson (four Arizona ROC licenses). Choose what describes you and send us this property’s address and public-record report for review — the address, parcel, report link and permit record travel with the request automatically.

What describes you?
Call (520) 308-6235

The contractor’s read is a plain-English brief of the record above, written by AI — what it shows across electrical, mechanical and the building itself, what is missing for the era, and what to verify on site.

How this report was built

This is a reading of public records for parcel 101046960 — 33 permits on file from 1998 to 2024 (13 historical, 5 building, 5 right of way, 4 other structures) — assembled from the Pima County parcel file, the City of Tucson GIS layers, and Pima County’s Accela permit portal (searched by parcel and by address, because the county’s parcel links break on older records). Public records last checked 2026-08-16; the record is re-read at least weekly. Each permit and code case links to its official file. The verdicts are inferences from what was permitted and when, and from the era the building went up; they are not an inspection, and nothing here confirms what is installed. A permit that is present is strong evidence; a permit that is absent is weak evidence — plenty of work is never permitted, and older county records were only partly moved online.

The interactive version of this report can also read the plan sheets behind a City of Tucson permit and write a contractor’s brief of the whole record — those buttons appear once the page finishes loading. Written and maintained by Arizona Electrical Solutions, LLC, a licensed Tucson contractor (ROC 276948 CR-11 electrical, ROC 326401 CR-39 HVAC, ROC 329360 KB-1, ROC 312437 KA).

Look up a different address: Tucson permit history & electrical upgrade check · see permit data by neighborhood.